AMIN MOHAMMADI

Mr. AMIN MOHAMMADI

Old Dominion University, Norfolk, Massachusetts, USA
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2024 in Sports
Verified
Journal Article
Open access
PDF file
AMAMIN MOHAMMADI
AMIN MOHAMMADI
SSSeyedehsan Sakhtemani
Seyedehsan Sakhtemani
LTLukas Trimmel
Lukas Trimmel
KPKrisztina Petricsevics
Krisztina Petricsevics
AMAlexandra Makai
Alexandra Makai
PTPéter Sándor Tardi
Péter Sándor Tardi
Background: The Fascial Distortion Model (FDM) is a relatively new manual therapy approach in the field of musculoskeletal physical therapy, and its potential effectiveness in treating chronic ankle instability (CAI) remains unexplored. Methods: A randomized controlled trial with 23 participants was conducted. Patients were randomly assigned to either the FDM + balance–strength training (BST) group (n = 8), receiving extra FDM sessions weekly in addition to two sessions of BST, or the BST group (n = 7). Healthy controls (n = 8) did not receive any treatment and participated only in pre- and post-test measurements. Objective measurements including Y-Balance Test Lower Quarter (YBT-LQ), Flamingo Balance Test (FBT), Weight-Bearing Lunge Test (WBLT), ankle joint range of motion (ROM), and Cumberland Ankle Instability Tool (CAIT) were recorded at baseline and the end of the intervention. The results demonstrated significant differences between the FDM + BST and BST groups for supination ROM (p = 0.008) and similarly for WBLT (p = 0.041), FBT (p = 0.40), YBT-LQ (p = 0.023), and CAIT score (p = 0.008). Moreover, while both groups demonstrated significant improvement at the post-test compared with their pre-test for plantarflexion and pronation ROM, WBLT, and CAIT score, the FDM + BST group demonstrated significant improvements in supination ROM, FBT, and YBT-LQ. Conclusion: Our study suggests that the addition of FDM concepts to a BST may lead to enhanced improvements in ankle ROM, static and dynamic balance, and self-reported outcomes in individuals with CAI compared to BST.

28 March 2026 in Clinical Rheumatology
Verified
Journal Article
Open access
PDF file
AMAMIN MOHAMMADI
AMIN MOHAMMADI
saeed eshghisaeed eshghi
saeed eshghi
IMIman Mohammadi
Iman Mohammadi
Patrick WilsonPatrick Wilson
Patrick Wilson
RMRyan McCann
Ryan McCann
Purpose: To systematically synthesize ultrasound (US) evidence on talar cartilage morphology and load-induced deformation in individuals with chronic ankle instability (CAI), and to map methodological approaches (acquisition, outcome definitions, loading paradigms, and normalization) to inform protocol standardization. Methods: PubMed, Web of Science, and EBSCO were searched (March 31, 2025). Eligible studies reported quantitative US-derived talar cartilage morphology (e.g., thickness, cross-sectional area [CSA]) and/or deformation following standardized loading in CAI and comparison groups. Due to heterogeneity in imaging protocols, loading tasks, and outcome definitions, findings were synthesized narratively and organized by outcome domain. Results: Across available cohorts, load-induced deformation was the most consistently differentiating signal: CAI groups generally demonstrated greater deformation than controls, with more frequent regional effects at the medial talar dome. Evidence for baseline (unloaded) morphological differences was mixed, with some studies reporting no group differences and others reporting larger CSA in CAI. Associations between deformation and neuromechanical measures (e.g., inversion laxity, postural control, hop biomechanics, ground reaction forces) were reported but were protocol- and cohort-dependent. Conclusions: Current evidence, limited by few unique cohorts, partial non-independence across publications, and heterogeneous acquisition/loading/normalization procedures, suggests that B-mode US can quantify talar cartilage morphology and detect load-induced deformation differences in CAI in research settings. Talar cartilage ultrasonography should be considered investigational until standardized acquisition and analysis procedures and longitudinal validity are established. Key Points • Ultrasound can quantify talar cartilage morphology and load-induced deformation in individuals with chronic ankle instability. • Load-induced talar cartilage deformation appears to be the most consistent ultrasound-derived feature differentiating chronic ankle instability from healthy controls. • Evidence for baseline talar cartilage morphology differences is mixed, likely reflecting heterogeneity in cohorts and imaging/loading protocols. • Standardized acquisition, loading, and analysis methods, along with independent longitudinal validation, are needed before clinical translation.

28 October 2026 in Sleep Health
Verified
Journal Article
Closed access
AMAMIN MOHAMMADI
AMIN MOHAMMADI
JLJoshua T. Lawton
Joshua T. Lawton
ESEric Schussler
Eric Schussler
TCThomas Campbell
Thomas Campbell

16 October 2026 in Brain Injury
Verified
Journal Article
Closed access
AMAMIN MOHAMMADI
AMIN MOHAMMADI
JLJoshua T. Lawton
Joshua T. Lawton
ESEric Schussler
Eric Schussler
TCThomas R. Campbell
Thomas R. Campbell
Sport-related concussion is an important public health concern internationally, particularly in sports involving collision, contact, rapid acceleration–deceleration, or fall risk. In the United Sta...

11 September 2026 in Gait & Posture
Verified
Journal Article
Closed access
AMAMIN MOHAMMADI
AMIN MOHAMMADI
SESaeed Eshghi
Saeed Eshghi
ESEric Schussler
Eric Schussler
RMRyan S. McCann
Ryan S. McCann

30 September 2026 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
saeed eshghisaeed eshghi
saeed eshghi
AMAMIN MOHAMMADI
AMIN MOHAMMADI
ESEric Schussler
Eric Schussler
RMRyan S McCann
Ryan S McCann
Smartphone-based sensors may provide a complement to laboratory-based force-plate balance assessment; however, validation studies have not established whether smartphone–force-plate associations and agreement vary across combined manipulations of visual input and support-surface reliability, or which smartphone-derived metrics are most sensitive to sensory challenges. Therefore, this study compared smartphone-derived and force-plate-derived sway metrics during virtual reality-based clinical test of sensory interaction and balance (VR-CTSIB) conditions. This secondary analysis included 40 adults (20 with chronic ankle instability and 20 healthy controls). Participants completed 30 s double-leg stance trials under six VR-CTSIB conditions combining firm or foam surfaces with NormVision, DisplayOff, and SwayRef visual environments. Sway data were collected using a force plate and a smartphone-based head-mounted display. Root mean square (RMS) and mean absolute value (MAV) were calculated in the mediolateral (ML) and anterior–posterior (AP) directions. Pearson correlations with false discovery rate (FDR) correction were used to examine device associations, Bland–Altman analyses assessed agreement, and Cohen’s dz quantified condition sensitivity. In the primary analyses, ML smartphone metrics showed larger correlation coefficients with force-plate measures than AP metrics. The largest correlations were observed in the firm NormVision condition for ML RMS with force-plate ML velocity RMS ( r = 0.705, FDR-adjusted p < 0.001) and ML MAV with force-plate ML velocity MAV ( r = 0.679, FDR-adjusted p < 0.001). Force-plate outcomes demonstrated greater condition sensitivity than smartphone-derived outcomes. Among smartphone metrics, ML MAV and RMS in the SwayRef condition showed the largest effects ( dz = 0.895 and 0.876, respectively). Bland–Altman analyses showed systematic bias, with agreement varying across metrics and conditions. Overall, smartphone-derived sway metrics may provide complementary information during VR-based balance assessment, particularly in the ML direction. However, associations, agreement, and condition sensitivity varied by metric and sensory condition, indicating that smartphone- and force-plate-derived measures should not be interpreted as interchangeable.