Amir Reza Vazifeh

Mr. Amir Reza Vazifeh

Electrical and Computer Engineering, Princeton University, Princeton, Florida, USA
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BBBardia Baraeinejad
Bardia Baraeinejad
MSMasood Fallah Shayan
Masood Fallah Shayan
Amir Reza VazifehAmir Reza Vazifeh
Amir Reza Vazifeh
DRDiba Rashidi
Diba Rashidi
MHMohammad Saberi Hamedani
Mohammad Saberi Hamedani
MFMohammad Fakharzadeh
Mohammad Fakharzadeh
This paper reports the development of a new smart ECG monitoring system, consisting of the related hardware, firmware, and IoT-based web service for AI assisted arrhythmia detection and a complementary Android application for data streaming. The hardware aspect of this research proposes an ultra-low power patch sampling ECG data at 256 samples/s with 16-bit resolution. The battery life of the device is two weeks per charging, which alongside the flexible and slim (193.7 mm × 62.4 mm × 8.6 mm) and lightweight (43 g) allows the user to continue real life activities while the real-time monitoring is being done without interruption. The power management is achieved through the usage of switching converters, ultra-low power component choice as well as intermittent usage of them through firmware optimization. A novel data encoding method is also proposed to allow compression of data and lower the runtime. The software aspect, in addition to the web ECG analysis platform and the Android streaming and monitoring application, provides an arrhythmia detection service. The key innovations in this regard are the usage of a set of new factors in determining arrhythmia that grants higher accuracy while retaining the detection near-real-time. The arrhythmia detection algorithm shows 98.7% accuracy using Artificial Neural Network and K-Nearest Neighbors methods, and 98.1% using Decision Tree method on test data set.

23 February 2026 in Optics Express
Verified
Journal Article
Closed access
Amir Reza VazifehAmir Reza Vazifeh
Amir Reza Vazifeh
CWCongli Wang
Congli Wang
AJAmogh Joshi
Amogh Joshi
ICIlya Chugunov
Ilya Chugunov
JSJipeng Sun
Jipeng Sun
FHFelix Heide
Felix Heide
Fiber bundle imaging systems suffer from sampling artifacts such as honeycomb patterns due to their discrete and non-uniform fiber layout, fundamentally limiting image resolution. Conventional reconstruction methods rely on precise calibration of the fiber layout or learning from paired datasets, both of which have limited generalization across imaging setups and require sample-specific preparation. We present an unsupervised method for reconstructing high-resolution images using a burst of misaligned frames that does not require known fiber layout, paired training data, or per-sample calibration. Our approach jointly solves motion estimation and image reconstruction through test-time training. We model each burst frame as a deformed observation of a single canonical view, parameterizing the underlying motion with a coordinate-based network. A second coordinate-based network learns a joint super-resolved scene representation shared across aligned frames. Both networks are trained jointly end-to-end without paired ground truth or external supervision. Simulation and experimental results demonstrate that our method robustly removes fiber bundle artifacts and generalizes to various sample types. We also released a benchmark dataset for optical fiber bundle imaging to facilitate future research.

30 May 2026 in Informatics in Medicine Unlocked
Verified
Journal Article
Open access
Amir Reza VazifehAmir Reza Vazifeh
Amir Reza Vazifeh
JFJason W. Fleischer
Jason W. Fleischer

28 February 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
AAArda Altintepe
Arda Altintepe
ARAsu Rustemli
Asu Rustemli
Amir Reza VazifehAmir Reza Vazifeh
Amir Reza Vazifeh
JFJason W. Fleischer
Jason W. Fleischer
Background/Objectives: Dilated cardiomyopathy (DCM) and hypertrophic cardiomyopathy (HCM) are common cardiomyopathies associated with heart failure. Electrocardiogram (ECG) screening before an echocardiogram could help streamline diagnosis, particularly in rural areas. Prior ECG–machine learning (ML) studies do not use open-source data when studying cardiomyopathy, and very few proprietary studies directly compare HCM and DCM or address ECG differences within obstructive (HOCM) and non-obstructive HCM (HNCM). Methods: Standard and vectorcardiogram-derived (VCG) ECG features were extracted from the MIMIC-IV-ECG database. The final cohort comprised 599 patients (HCM = 208 [HOCM = 99, HNCM = 53, unknown = 56]; DCM = 391 [ischemic cardiomyopathy with left ventricular dilation = 250, non-ischemic = 141]). Logistic regression (LR) and extreme gradient boosting (XGBoost) with five-fold cross-validation separated HCM from ischemic cardiomyopathy with left ventricular dilation (DCM-I) and non-ischemic DCM (DCM-NI), and HOCM from HNCM. Results: Using the area under the receiver-operating-characteristic curve (AUC-ROC) as the performance metric, LR achieved high discrimination of HCM from DCM-I (0.92) and DCM-NI (0.90). However, differentiating HOCM from HNCM proved more difficult (XGBoost = 0.81; LR = 0.75). Both DCM subtypes (especially ischemic) showed lower QRS amplitudes and right-posterior ventricular gradient orientation; HCM displayed higher amplitudes and larger, more complex T-loops. Within HCM, HOCM had stronger leftward electrical activity and more dipolar to non-dipolar QRS energy after singular value decomposition. Conclusions: Using only open-access data, we demonstrate an interpretable ECG-based pipeline that discriminates cardiomyopathy and highlights distinct features. While detecting obstruction remains difficult, ECG features provide measurable separation, supporting possible diagnostic screening and offering a reproducible framework for future studies.