Ana Paula Borges

Dr. Ana Paula Borges

Coimbra Hospital and Universitary Centre (CHUC), Coimbra, Portugal
+1
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2023 in Tomography
Verified
Journal Article
Open access
PDF file
ABAna Paula Borges
Ana Paula Borges
CACélia Antunes
Célia Antunes
LCLuís Curvo-Semedo
Luís Curvo-Semedo
Dual-energy computed tomography (DECT) uses different energy spectrum x-ray beams for differentiating materials with similar attenuation at a certain energy. Compared with single-energy CT, it provides images with better diagnostic performance and a potential reduction of contrast agent and radiation doses. There are different commercially available DECT technologies, with machines that may display two x-ray sources and two detectors, a single source capable of fast switching between two energy levels, a specialized detector capable of acquiring high- and low-energy data sets, and a filter splitting the beam into high- and low-energy beams at the output. Sequential acquisition at different tube voltages is an alternative approach. This narrative review describes the DECT technique using a Q&A format and visual representations. Physical concepts, parameters influencing image quality, postprocessing methods, applicability in daily routine workflow, and radiation considerations are discussed. Differences between scanners are described, regarding design, image quality variabilities, and their advantages and limitations. Additionally, current clinical applications are listed, and future perspectives for spectral CT imaging are addressed. Acknowledging the strengths and weaknesses of different DECT scanners is important, as these could be adapted to each patient, clinical scenario, and financial capability. This technology is undoubtedly valuable and will certainly keep improving.

9 May 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
ABAna Paula Borges
Ana Paula Borges
CACélia Antunes
Célia Antunes
FCFilipe Caseiro-Alves
Filipe Caseiro-Alves
Using two different energy levels, dual-energy computed tomography (DECT) allows for material differentiation, improves image quality and iodine conspicuity, and allows researchers the opportunity to determine iodine contrast and radiation dose reduction. Several commercialized platforms with different acquisition techniques are constantly being improved. Furthermore, DECT clinical applications and advantages are continually being reported in a wide range of diseases. We aimed to review the current applications of and challenges in using DECT in the treatment of liver diseases. The greater contrast provided by low-energy reconstructed images and the capability of iodine quantification have been mostly valuable for lesion detection and characterization, accurate staging, treatment response assessment, and thrombi characterization. Material decomposition techniques allow for the non-invasive quantification of fat/iron deposition and fibrosis. Reduced image quality with larger body sizes, cross-vendor and scanner variability, and long reconstruction time are among the limitations of DECT. Promising techniques for improving image quality with lower radiation dose include the deep learning imaging reconstruction method and novel spectral photon-counting computed tomography.

8 May 2023 in Thyroid Research
Verified
Journal Article
Open access
PDF file
ABAna Paula Borges
Ana Paula Borges
CACélia Antunes
Célia Antunes
FCFilipe Caseiro-Alves
Filipe Caseiro-Alves
PDPaulo Donato
Paulo Donato
Background: Ultrasound-based classification systems allow stratification of thyroid nodules to recommend fine-needle aspiration (FNA) based on their malignancy risk. However, these have discrepancies that may have an impact in thyroid cancer detection. We aimed to compare European Thyroid Association (EU-TIRADS) and American College of Radiology (ACR TI-RADS), in terms of FNA indication and diagnostic performance. Methods: Retrospective study of 665 thyroid nodules from 598 patients who underwent ultrasound and fine-needle aspiration at a tertiary-care institution between January 1st of 2016 and July 31st of 2019. Based on their sonographic features they were classified according to the EU-TIRADS and ACR TI-RADS classification and then their cytological results were obtained. Differences in FNA indications according to these two classifications were analysed. In patients who underwent surgical removal of the nodules, the final pathological diagnosis was obtained. Results: A statistically significant association was found between EU-TIRADS and ACR TI-RADS classification systems (p < 0.001). ACR TI-RADS allowed greatest reduction in FNA performed (32% vs 24.5%). A different risk category was obtained in 174 (26.1%) nodules, mostly higher with EU-TIRADS. The indication to FNA changed in 54 (8.1%) nodules (49 only indicated following EU-TIRADS recommendations), of which 4 had Bethesda IV and 5 had Bethesda III cytology. The FNA indication in a higher number of nodules using EU-TIRADS was due to difference in the dimensional threshold for FNA on low-risk nodules; to the fact that hypoechogenicity in a mixed nodule ascribes it moderate risk, while using ACR TI-RADS it would only be considered of low risk, and to the use of isolated sonographic features, namely marked hypoechogenicity, microcalcifications and irregular margins, to automatically categorize a nodules as high risk in EU-TIRADS, while ACR TI-RADS requires a group of potentially suspicious features to consider a nodule of high risk. The analysis of pathology proven nodules revealed equally good sensitivity of both systems in the detection of malignancy, but weak specificity, slightly greater with ACR TI-RADS (27.1% vs 18.6%). Conclusions: The EU-TIRADS and ACR TI-RADS are both suitable to assess thyroid nodules and through risk stratification avoid unnecessary FNA. FNA was less performed using ACR TI-RADS, which was slightly more efficiency in excluding malignancy.

18 February 2023 in Abdominal Radiology
Verified
Journal Article
Open access
PDF file
ABAna Paula Borges
Ana Paula Borges
CACélia Antunes
Célia Antunes
PDPaulo Donato
Paulo Donato
Purpose: To study the association between median arcuate ligament compression (MALC) of celiac artery (CA) and splanchnic artery aneurysms/pseudoaneurysms (SAAPs) submitted to endovascular embolization. Methods: Single center retrospective study of embolized SAAPs between 2010 and 2021, to evaluate the prevalence of MALC, and compare demographic data and clinical outcomes between patients with and without MALC. As a secondary objective, patient characteristics and outcomes were compared between patients with different causes of CA stenosis. Results: MALC was found in 12.3% of 57 patients. SAAPs were more prevalent in the pancreaticoduodenal arcades (PDAs) in patients with MALC, compared to those without MALC (57.1% vs. 10%, P = .009). Patients with MALC had a greater proportion of aneurysms (71.4% vs. 24%, P = .020), as opposed to pseudoaneurysms. Rupture was the main indication for embolization in both groups (71.4% and 54% of patients with and without MALC, respectively). Embolization was successful in most cases (85.7% and 90%), with 5 immediate (28.6% and 6%) and 14 non-immediate (28.6% and 24%) post-procedure complications. Thirty and 90-day mortality rate were 0% in patients with MALC, and 14% and 24% in patients without MALC. Atherosclerosis was the only other cause of CA stenosis, in 3 cases. Conclusions: In patients with SAAPs submitted to endovascular embolization, the prevalence of CA compression by MAL is not uncommon. The most frequent location for aneurysms in patients with MALC is in the PDAs. Endovascular management of SAAPs is very effective in patients with MALC, with low complications, even in ruptured aneurysms. Graphical

5 April 2023 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
ABAna Paula Borges
Ana Paula Borges
ASAntónio V. Silva
António V. Silva
PDPaulo Donato
Paulo Donato