Andrea Santamaria-Laorden

Prof. Dr. Andrea Santamaria-Laorden

European University of Madrid, Madrid, Spain
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Jaime OrejasJaime Orejas
Jaime Orejas
BGBeatriz Gimenez-Gonzalez
Beatriz Gimenez-Gonzalez
JOSE IGNACIO ORTIZ-COLLADOJOSE IGNACIO ORTIZ-COLLADO
JOSE IGNACIO ORTIZ-COLLADO
IVIsrael Thuissard Vasallo
Israel Thuissard Vasallo
Andrea Santamaria-LaordenAndrea Santamaria-Laorden
Andrea Santamaria-Laorden
(1) Multiple in vitro studies reported insufficient accuracy of intraoral scanners (IOSs) for complete-arch multiple implant impression. The aim of the study is to analyze the precision of three IOSs, PIC dental (Pic dental, Iditec North West SL), TRIOS 3 (3Shape), and True Definition (Midmark Corporation) and the influence of several factors in the edentulous complete maxillary and mandibular arch. (2) A fully edentulous patient with eight implants in the maxillary and in the mandibular jaw was selected. Five impressions were taken per system and arch. A suprastructure was designed on each digital working cast. The precision was analyzed comparing each of the 28 distances and seven relative angulations of the abutments of all the designed suprastructures. The descriptive statistics, the Student’s t-test, and the ANOVA test were used to analyze the data (α = 0.05). (3) Significant differences were observed when comparing the IOSs in some of the distances and angulations. (4) The increase in the distance between implants affected the precision of T and TD but not the PIC system. The type of arch did not affect the PIC precision, but the T and TD systems performed worse in the mandibular arch. The system with the best precision was the PIC, followed by TD, and then T.

1 June 2013 in Implant Dentistry
Verified
Journal Article
Closed access
FMFrancisco Martínez-Rus
Francisco Martínez-Rus
CGCarmen García
Carmen García
Andrea Santamaria-LaordenAndrea Santamaria-Laorden
Andrea Santamaria-Laorden
Mutlu ÖzcanMutlu Özcan
Mutlu Özcan
GRGuillermo Pradíes Ramiro
Guillermo Pradíes Ramiro
To evaluate the effect of various implant-level impression techniques on the accuracy of definitive casts for a multiple internal connection implant system with different implant angulations and subgingival depths. Six tapered Screw-Vent implants were placed in a reference model with different angles (0, 15, and 30 degrees) and subgingival positions (0, 1, and 3 mm). Twenty medium-consistency polyether impressions of this model were made with 4 techniques (n = 5 per group): (1) indirect technique, (2) unsplinted direct technique, (3) acrylic resin-splinted direct technique, and (4) metal-splinted direct technique. Impressions were poured with type IV dental stone. The interimplant distances were measured for casts using a coordinate measuring machine and the deviations compared with the reference model were calculated. Data were analyzed using intraclass correlation coefficient, ANOVA and Bonferroni test (α = 0.05). Four impression procedures showed significant differences (P = 0.0001). Only group 4 casts showed no significant differences in comparison with the reference model (P = 0.666) (ANOVA repeated measures). The impression procedure affected the accuracy of definitive casts. The metal-splinted direct technique produced the most accurate casts, followed by acrylic resin-splinted direct, indirect, and unsplinted direct techniques.

15 July 2025 in Journal of Dentistry
Verified
Journal Article
Open access
Andrea Santamaria-LaordenAndrea Santamaria-Laorden
Andrea Santamaria-Laorden
AMAlicia Martínez Marugán
Alicia Martínez Marugán
CACristina Andreu-Vázquez
Cristina Andreu-Vázquez
Jaime OrejasJaime Orejas
Jaime Orejas
To compare the accuracy of complete arch implant capture using two extraoral photogrammetry (PG) systems (PIC system® and PIC app®). An edentulous cast with six multiunit abutment (MUA) analogs was digitised and 30 complete arch implant captures were performed by each PG system. Euclidean linear and angular measurements were obtained on the digitised reference model with a coordinate measuring machine (CMM) and were used to compare the discrepancies with the same measurements obtained using the PG devices. The Mann-Withney U test was used to analyse the trueness data, and the Levene test was used to analyse the precision values (α=0.05). The mean ± standard deviation results for the distance and angulation measurements obtained using the PIC system and PIC app, respectively (18.21 ± 12.21 μm and 0.10 ± 0.07 degrees, and 30.92 ± 20.88 μm and 0.16 ± 0.09 degrees, respectively). The mean differences between the PIC app® and PIC system® were 12.70 μm (95 % confidence interval [CI]: 10.47, 14.94; p < 0.001) and 0.07 degrees (95 % CI: 0.05, 0.07; p < 0.001) for the Euclidean linear and angular measurements, respectively. The PIC system® demonstrated a greater precision (lower variance, p = 0.035) for linear measurements; however, both extraoral PG systems exhibited similar precision (equal variances) for angular measurements (p = 0.112). PIC system® exhibited greater trueness for linear and angular measurements and linear precision. However, the impact of these statistically significant differences may not be clinically relevant. The PIC system® has been reported as an accurate PG method for recording the three-dimensional implant positions in complete arch prostheses; however, high equipment costs limit its widespread adoption. With the PIC app®, smartphones provide the democratisation of the PIC system® using an accurate and cost-effective approach.

25 November 2025 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
Andrea Santamaria-LaordenAndrea Santamaria-Laorden
Andrea Santamaria-Laorden
RCRaquel Castillo-Oyagüe
Raquel Castillo-Oyagüe
AMAlicia Martínez-Marugán
Alicia Martínez-Marugán
JSJose Luis Quirós Sánchez
Jose Luis Quirós Sánchez
CACristina Andreu-Vázquez
Cristina Andreu-Vázquez
Jaime OrejasJaime Orejas
Jaime Orejas
A photogrammetry algorithm integrated into a smartphone application has been proposed as an alternative to photogrammetry scanners for complete arch digital implant recording. Clinical studies, however, are lacking. The purpose of this clinical study was to evaluate the accuracy of a photogrammetry app for complete arch prostheses supported by 6 implants. A total of 8 participants with 10 completely edentulous arches with 6 multiunit implant abutments were recruited. For each participant, 5 recordings were made using a photogrammetry app (PIC app; Pic dental), and 1 recording with a photogrammetry device (PIC system; PIC dental). From the resulting standard tessellation language (STL) files, linear and angular Euclidean distances were recorded. A statistical analysis of the measurements obtained was used to determine their trueness and precision. The Shapiro-Wilk tests were run to analyse the trueness data, and the Levene test was used to assess the precision values (α=.05). The mean ±standard deviation absolute difference between the PIC system and PIC app was 21 ±16 µm and 0.20 ±0.17 degrees. The interimplant distance did not signifficantly affect linear trueness (P>.05) or angular trueness (P>.05). The arch type did affect linear trueness P<.001, but did not affect angular truness (P=.310). The results suggested that the photogrammetry app was sufficiently accurate for recording implant locations in complete arch prostheses supported by 6 implant abutments.

16 April 2023 in Healthcare
Verified
Journal Article
Open access
PDF file
TRTommaso Rinaldi
Tommaso Rinaldi
Andrea Santamaria-LaordenAndrea Santamaria-Laorden
Andrea Santamaria-Laorden
Jaime OrejasJaime Orejas
Jaime Orejas
LRLaura Godoy Ruiz
Laura Godoy Ruiz
CGCarlos Serrano Granger
Carlos Serrano Granger
PCPablo Gómez Cogolludo
Pablo Gómez Cogolludo
(1) Gingival inflammation is an ongoing challenge in tooth-supported fixed restorations, especially when the prosthetic margin does not consider the supracrestal tissues of patients. This case report aimed to present the case of a patient who was periodontally compromised due to a previous invasion of the supracrestal tissue attachment with fixed restorations and evaluate the healing response of periodontal tissues to a vertical edgeless preparation technique: bleeding upon probing (BOP), periodontal probing depth (PPD) and clinical attachment level (CAL). (2) After tooth preparation, the new restorations were adapted, this time without invading the supracrestal space of the patient, and CAD/CAM monolithic zirconia crowns were fabricated. (3) Optimal maturation of the soft tissue was observed, achieving correction of the marginal contour of periodontal tissues and improvement of periodontal indexes. (4) It can be concluded that the BOPT technique combined with a full digital workflow is a valid option for the correction and remodeling of gingival architecture.

1 January 2025 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
MBMeriem Benabdallah-M’rAbat
Meriem Benabdallah-M’rAbat
Andrea Santamaria-LaordenAndrea Santamaria-Laorden
Andrea Santamaria-Laorden
SBSabina Francesca Bertuol-Gessi
Sabina Francesca Bertuol-Gessi
AMAlicia Martínez-Marugán
Alicia Martínez-Marugán
Ana SuarezAna Suarez
Ana Suarez
Jaime OrejasJaime Orejas
Jaime Orejas
Benabdallah-M’RabatMeriem, et al. J Adv Prosthodont. 2025 Oct;17(5):292-303. https://doi.org/10.4047/jap.2025.17.5.292