Andres Emilio Hurtado-Perez

Dr. Andres Emilio Hurtado-Perez

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2025 in Biomimetics
Verified
Journal Article
Open access
PDF file
AHAndres Emilio Hurtado-Perez
Andres Emilio Hurtado-Perez
MTManuel Toledano
Manuel Toledano
ICIrving Cruz-Albarran
Irving Cruz-Albarran
ALAlejandra Lopez-Zúñiga
Alejandra Lopez-Zúñiga
AMAdrian Moreno-Perez
Adrian Moreno-Perez
CPCarlos Perez-Ramirez
Carlos Perez-Ramirez
This review provides an in-depth examination of the technologies and methods used for the acquisition and processing of kinetic and kinematic variables in human motion analysis. This review analyzes the capabilities and limitations of motion-capture cameras (MCCs), inertial measurement units (IMUs), force platforms, and other prototype technologies. The role of advanced processing techniques, including filtering and transformation methods, and the increasing integration of artificial intelligence (AI) and machine learning (ML) for data classification is also discussed. These advancements enhance the precision and efficiency of biomechanical analyses, paving the way for more accurate assessments of human movement patterns. The review concludes by providing guidelines for the effective application of these technologies in both clinical and research settings, emphasizing the need for comprehensive validation to ensure reliability. This comprehensive overview serves as a valuable resource for researchers and professionals in the field of biomechanics, guiding the selection and application of appropriate technologies and methodologies for human movement analysis.

3 June 2026 in Biomimetics
Verified
Journal Article
Open access
PDF file
AAAlejandro Antonio Salinas Aguilar
Alejandro Antonio Salinas Aguilar
SASebastian Arriaga-Marin
Sebastian Arriaga-Marin
CPCarlos Perez-Ramirez
Carlos Perez-Ramirez
ICIgnacio Cervantes-Gutierrez
Ignacio Cervantes-Gutierrez
ICIrving Cruz-Albarran
Irving Cruz-Albarran
MTManuel Toledano
Manuel Toledano
Effective diabetes management heavily relies on appropriate insulin administration, which strongly depends on the correct administration strategy. In this sense, insulin administration plays a fundamental role, as its use depends on the patient’s clinical condition and diabetes type. Traditional syringe-based methods require proper training to ensure that insulin is successfully delivered into the subcutaneous tissue, where it can be absorbed and metabolized; however, it is desirable to develop an insulin applicator that does not require training for its appropriate use. Aiming to provide support solutions that help patients to develop a correct administration technique, a biodesign-based methodology, coupled with biomimetic concepts, is employed to design a device that assists the user in creating a stable skin fold and guiding needle orientation during injection without requiring exhaustive training for device usage. A three-step approach is employed for the design, where computational fluid dynamics (CFD) and finite element analysis (FEA) methods are employed to ensure that the device produces a laminar insulin flow and the device strength is tested. It should be pointed out both methods are required since complications produced by sudden flows must be avoided, with CFD allowing assessment of the device mechanical properties in terms of the device strength. Initial functional evaluation indicates that the proposed approach does not require extensive training or complex operational procedures, facilitating its integration into everyday use. The device design is validated from the results obtained for the CFD analysis, as no turbulent flow is produced, whereas the FEA indicates that the geometrical form can handle the stresses produced by the folding generation without generating excessive deformations. Moreover, an infrared thermography analysis is also carried out to find out if the folding force generation is located in the zone of interest, the results of which indicate that the device operates in the desired physical zone.

4 January 2025
Verified
Book Chapter
Closed access
PDF file
PJPortos Juárez Francisco Josué
Portos Juárez Francisco Josué
LALima Zempoaltecatl Adrian
Lima Zempoaltecatl Adrian
FAFélix García Edgar Antonio
Félix García Edgar Antonio
AHAndres Emilio Hurtado-Perez
Andres Emilio Hurtado-Perez