Andy Hsien Wei Koh

Dr. Andy Hsien Wei Koh

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AKAndy Hsien Wei Koh
Andy Hsien Wei Koh
RCRuss Chess-Williams
Russ Chess-Williams
ALAnna Lohning
Anna Lohning
Trace amines such as p-tyramine, p-octopamine and p-synephrine are found in low concentrations in animals and plants. Consumption of pre-workout supplements containing these plant-derived amines has been associated with cardiovascular side effects. The aim of this study was to determine the mechanisms of action of these trace amines on porcine isolated coronary and mesenteric arteries. Noradrenaline caused contraction of mesenteric arteries and relaxation of coronary arteries. In both tissues, all three trace amines induced contractions with similar potencies and responses were unaffected by the β-adrenoceptor antagonist propranolol (1 µM), the nitric oxide synthase inhibitor L-NNA (100 µM), or the TAAR-1 antagonist, EPPTB (100 nM). However, the contractile responses of mesenteric arteries, but not coronary arteries, were significantly reduced by depletion of endogenous noradrenaline. Mesenteric responses to all three amines were abolished in the presence of prazosin (1 µM) whereas residual contractile responses remained in the coronary artery which were inhibited by a high concentration (100 µM) of EPPTB. The results suggest complex responses of the coronary artery to the trace amines, with activity at α1-adrenoceptors and potentially TAARs other than TAAR-1. In contrast the actions of the amines on the mesenteric artery appeared to involve indirect sympathomimetic actions and direct actions on α1-adrenoceptors.

17 April 2024 in Microorganisms
Verified
Journal Article
Open access
PDF file
AGAdrian Goldsworthy
Adrian Goldsworthy
MOMatthew Olsen
Matthew Olsen
AKAndy Hsien Wei Koh
Andy Hsien Wei Koh
TDThibaut Demaneuf
Thibaut Demaneuf
GSGobind Deep Singh
Gobind Deep Singh
LTLotti William Tajouri
Lotti William Tajouri
Extended reality (XR) devices, including virtual and augmented reality head-mounted displays (HMDs), are increasingly utilised within healthcare to provide clinical interventions and education. Currently, XR devices are utilised to assist in reducing pain and improving psychological outcomes for immunocompromised patients in intensive care units, palliative care environments and surgical theatres. However, there is a paucity of research on the risks of infection from such devices in healthcare settings. Identify existing literature providing insights into the infection control risk XR HMDs pose within healthcare facilities and the efficacy of current infection control and cleaning procedures. Three databases (PubMed, Embase and CINAHL) in addition to Google Scholar were systematically searched. A total of seven studies were identified for this review. Microorganisms, including pathogenic bacteria (e.g., Staphylococcus aureus and Pseudomonas aeruginosa), were found to be present on XR HMDs. Published cleaning and infection control protocols designed to disinfect XR HMDs and protect users were heterogeneous in nature. Current cleaning protocols displayed varying levels of efficacy with microbial load affected by multiple factors, including time in use, number of users and XR HMD design features. In healthcare settings, fitting XR HMDs harbouring microorganisms near biological and mucosal entry points presents an infection control risk. An urgent revision of the Spaulding classification is required to ensure flexibility that allows for these devices to be reclassified from ‘Non-critical’ to ‘Semi-Critical’ depending on the healthcare setting and patient population (surgery, immunocompromised, burns, etc.). This review identified evidence supporting the presence of microorganisms on XR HMDs. Due to the potential for HMDs to contact mucosal entry points, devices must be re-considered within the Spaulding classification as ‘Semi-critical’. The existence of microbial contaminated XR HMDs in high-risk medical settings such as operating wards, intensive care units, emergency departments, labour and delivery wards and clinical areas with immunosuppressed patients requires urgent attention. Public health authorities have a duty of care to develop revised guidelines or new recommendations to ensure efficient sanitation of such devices.

1 January 2021 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
AKAndy Hsien Wei Koh
Andy Hsien Wei Koh
RCRuss Chess-Williams
Russ Chess-Williams
ALAnna Lohning
Anna Lohning

9 April 2021 in Drug Testing and Analysis
Verified
Journal Article
Closed access
PDF file
AKAndy Hsien Wei Koh
Andy Hsien Wei Koh
RCRuss Chess‐Williams
Russ Chess‐Williams
ALAnna Lohning
Anna Lohning

20 July 2017 in Australian Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
PRPhilip Ryan
Philip Ryan
AKAndy Hsien Wei Koh
Andy Hsien Wei Koh
ALAnna Elizabeth Lohning
Anna Elizabeth Lohning
SRSantosh Rudrawar
Santosh Rudrawar
An efficient synthesis of the O-linked glycosylamino acid Fmoc–l-Ser((Ac)3–ß-d-GlcNAc)-OH building block is described. The utility of the method was demonstrated with direct solid-phase O-glycosylation of the hydroxyl group on the amino acid (Ser) side chain of a human a-A crystallin-derived peptide (AIPVSREEK) in nearly quantitative glycosylation yield.