Ángel Luis Perales Gómez

Mr. Ángel Luis Perales Gómez

Facultad de Informática, Universidad de Murcia, Murcia, Spain
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2019 in IEEE Access
Verified
Journal Article
Open access
ÁGÁngel Luis Perales Gómez
Ángel Luis Perales Gómez
LMLorenzo Fernández Maimó
Lorenzo Fernández Maimó
Alberto Huertas CeldránAlberto Huertas Celdrán
Alberto Huertas Celdrán
Felix Garcia ClementeFelix Garcia Clemente
Felix Garcia Clemente
CSCristian Cadenas Sarmiento
Cristian Cadenas Sarmiento
RNRubén Méndez Nistal
Rubén Méndez Nistal
In recent decades, Industrial Control Systems (ICS) have been affected by heterogeneous cyberattacks that have a huge impact on the physical world and the people’s safety. Nowadays, the techniques achieving the best performance in the detection of cyber anomalies are based on Machine Learning and, more recently, Deep Learning. Due to the incipient stage of cybersecurity research in ICS, the availability of datasets enabling the evaluation of anomaly detection techniques is insufficient. In this paper, we propose a methodology to generate reliable anomaly detection datasets in ICS that consists of four steps: attacks selection, attacks deployment, traffic capture and features computation. The proposed methodology has been used to generate the Electra Dataset, whose main goal is the evaluation of cybersecurity techniques in an electric traction substation used in the railway industry. Using the Electra dataset, we train several Machine Learning and Deep Learning models to detect anomalies in ICS and the performed experiments show that the models have high precision and, therefore, demonstrate the suitability of our dataset for use in production systems.

6 December 2023 in Expert Systems with Applications
Verified
Journal Article
Open access
EBEnrique Tomás Martínez Beltrán
Enrique Tomás Martínez Beltrán
ÁGÁngel Luis Perales Gómez
Ángel Luis Perales Gómez
CFChao Feng
Chao Feng
PSPedro Sanchez
Pedro Sanchez
SBSergio López Bernal
Sergio López Bernal
Alberto Huertas CeldránAlberto Huertas Celdrán
Alberto Huertas Celdrán

5 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
LMLorenzo Fernández Maimó
Lorenzo Fernández Maimó
Alberto Huertas CeldránAlberto Huertas Celdrán
Alberto Huertas Celdrán
ÁGÁngel Luis Perales Gómez
Ángel Luis Perales Gómez
Felix Garcia ClementeFelix Garcia Clemente
Felix Garcia Clemente
JWJames Weimer
James Weimer
ILInsup Lee
Insup Lee
Medical Cyber-Physical Systems (MCPS) hold the promise of reducing human errors and optimizing healthcare by delivering new ways to monitor, diagnose and treat patients through integrated clinical environments (ICE). Despite the benefits provided by MCPS, many of the ICE medical devices have not been designed to satisfy cybersecurity requirements and, consequently, are vulnerable to recent attacks. Nowadays, ransomware attacks account for 85% of all malware in healthcare, and more than 70% of attacks confirmed data disclosure. With the goal of improving this situation, the main contribution of this paper is an automatic, intelligent and real-time system to detect, classify, and mitigate ransomware in ICE. The proposed solution is fully integrated with the ICE++ architecture, our previous work, and makes use of Machine Learning (ML) techniques to detect and classify the spreading phase of ransomware attacks affecting ICE. Additionally, Network Function Virtualization (NFV) and Software Defined Networking (SDN)paradigms are considered to mitigate the ransomware spreading by isolating and replacing infected devices. Different experiments returned a precision/recall of 92.32%/99.97% in anomaly detection, an accuracy of 99.99% in ransomware classification, and promising detection and mitigation times. Finally, different labelled ransomware datasets in ICE have been created and made publicly available.

23 September 2020 in Symmetry
Verified
Journal Article
Open access
PDF file
ÁGÁngel Luis Perales Gómez
Ángel Luis Perales Gómez
LMLorenzo Fernández Maimó
Lorenzo Fernández Maimó
Alberto Huertas CeldránAlberto Huertas Celdrán
Alberto Huertas Celdrán
Felix Garcia ClementeFelix Garcia Clemente
Felix Garcia Clemente
Industrial Control Systems (ICSs) are widely used in critical infrastructures to support the essential services of society. Therefore, their protection against terrorist activities, natural disasters, and cyber threats is critical. Diverse cyber attack detection systems have been proposed over the years, in which each proposal has applied different steps and methods. However, there is a significant gap in the literature regarding methodologies to detect cyber attacks in ICS scenarios. The lack of such methodologies prevents researchers from being able to accurately compare proposals and results. In this work, we present a Methodology for Anomaly Detection in Industrial Control Systems (MADICS) to detect cyber attacks in ICS scenarios, which is intended to provide a guideline for future works in the field. MADICS is based on a semi-supervised anomaly detection paradigm and makes use of deep learning algorithms to model ICS behaviors. It consists of five main steps, focused on pre-processing the dataset to be used with the machine learning and deep learning algorithms; performing feature filtering to remove those features that do not meet the requirements; feature extraction processes to obtain higher order features; selecting, fine-tuning, and training the most appropriate model; and validating the model performance. In order to validate MADICS, we used the popular Secure Water Treatment (SWaT) dataset, which was collected from a fully operational water treatment plant. The experiments demonstrate that, using MADICS, we can achieve a state-of-the-art precision of 0.984 (as well as a recall of 0.750 and F1-score of 0.851), which is above the average of other works, proving that the proposed methodology is suitable for use in real ICS scenarios.

31 March 2022 in Cluster Computing
Verified
Journal Article
Open access
PDF file
ÁGÁngel Luis Perales Gómez
Ángel Luis Perales Gómez
ÁLÁngel Luis
Ángel Luis
PLPedro E. Lopez-deTeruel
Pedro E. Lopez-deTeruel
PEPedro E.
Pedro E.
ARAlberto Ruiz
Alberto Ruiz
FJFélix J.
Félix J.
The race for automation has reached farms and agricultural fields. Many of these facilities use the Internet of Things technologies to automate processes and increase productivity. Besides, Machine Learning and Deep Learning allow performing continuous decision making based on data analysis. In this work, we fill a gap in the literature and present a novel architecture based on IoT and Machine Learning / Deep Learning technologies for the continuous assessment of agricultural crop quality. This architecture is divided into three layers that work together to gather, process, and analyze data from different sources to evaluate crop quality. In the experiments, the proposed approach based on data aggregation from different sources reaches a lower percentage error than considering only one source. In particular, the percentage error achieved by our approach in the test dataset was 6.59, while the percentage error achieved exclusively using data from sensors was 6.71.

6 August 2020 in Software: Practice and Experience
Verified
Journal Article
Closed access
PDF file
ÁGÁngel Luis Perales Gómez
Ángel Luis Perales Gómez
LMLorenzo Fernández Maimó
Lorenzo Fernández Maimó
ACAlberto Huertas Celdrán
Alberto Huertas Celdrán
FCFélix J. García Clemente
Félix J. García Clemente
MPManuel Gil Pérez
Manuel Gil Pérez
GPGregorio Martínez Pérez
Gregorio Martínez Pérez