19 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
MVMaria Teresa Villen
Maria Teresa Villen
Maria Paz ComechMaria Paz Comech
Maria Paz Comech
EMEduardo Martinez
Eduardo Martinez
Aníbal Antonio Prada HurtadoAníbal Antonio Prada Hurtado
Aníbal Antonio Prada Hurtado
Renewable power is expected to increase drastically in the coming years due to the energy transition. A large part of the newly installed generators will be connected to the power system through inverters and electronic converters, whose behaviour differs from the generators connected synchronously to the network. One of the main differences is the current contribution during symmetrical and asymmetrical faults which can affect protection systems. New grid codes establish requirements for fast current injection, but the converter’s maximum current limitations during faults make it difficult to establish control strategies for such current contribution. This paper studies the performance of faulted phase selector algorithm of a commercial relay under the current contribution from renewables before unbalanced faults. Two positive and negative sequence current injection strategies in compliance with new Spanish grid code requirements are proposed and tested under fault conditions in HiL (Hardware in the Loop). Test results show that the selected injection strategy affects the fault phase identification algorithm. Furthermore, the negative sequence injection requirements established in the new grid code improve the relay performance when line-to-line faults are applied, but they are not enough to identify all fault types.

9 May 2022 in Energies
Verified
Journal Article
Open access
PDF file
Aníbal Antonio Prada HurtadoAníbal Antonio Prada Hurtado
Aníbal Antonio Prada Hurtado
EMEduardo Martinez
Eduardo Martinez
MVMaria Teresa Villen
Maria Teresa Villen
Jose SaldanaJose Saldana
Jose Saldana
Many wide area monitoring, protection, and control (WAMPAC) systems are being deployed by grid operators to deal with critical operational conditions that may occur in power systems. Thanks to the real-time measurements provided by a set of distributed phasor measurement units (PMUs), different protection algorithms can be run in a central location. In this context, this article presents and validates a novel method that can be used as a backup protection for a selected area in a power system. It merges the integrated impedance angle (IIA) protection method with the theory of virtual buses in wide area electrical power systems. The backup protection works this way: once a fault is detected (pickup time), another delay (added to the pickup time) is defined in order to wait for the primary protection to act. If this does not happen, the algorithm generates its backup trip. The proposed method has been called the zone integrated impedance angle (Zone IIA). A real-time PMU laboratory has been used to test the proposed algorithm using a real-time digital simulator (RTDS). The algorithm has been programmed in a real-time automation controller (RTAC). It has been tested in two different simulated setups: first, a 400 kV transmission system, with and without the use of renewable energy sources (RES); second, a 150 kV submarine line between the Greece mainland and an island, which is currently the longest submarine alternating current connection in the world. The results obtained during the tests have yielded tripping times for area protection in the order of 48 ms, if no time delay is used between the fault detection and the trip order. According to the test results, the proposed method is stable, reliable, obedient, and secure, also with RES installed in the power system. Additionally, the method is selective, i.e., during the tests no trip was executed for external faults, no trip was executed in no-fault condition, and all the applied internal faults were detected and tripped correctly. Finally, the protection method is easy to implement. The method is also applicable to protection against short circuits in distribution systems. According to the trip times observed during the tests, it is clear that these algorithms are well suited to implement backup protections in transmission grids, even in scenarios with high penetration of renewable energies. Considering that backup trip times in transmission grids are usually set between 400 and 1000 ms, and that the actuation times obtained by the proposed algorithm are under 100 ms, the method is suitable for its use as a backup protection.

15 January 2024 in IEEE Access
Verified
Journal Article
Open access
MVMaria Teresa Villen
Maria Teresa Villen
MCMaría Paz Comech
María Paz Comech
Aníbal Antonio Prada HurtadoAníbal Antonio Prada Hurtado
Aníbal Antonio Prada Hurtado
Miguel Ángel OlivanMiguel Ángel Olivan
Miguel Ángel Olivan
DCDavid López Cortón
David López Cortón
CCCarlos Rodriguez Del Castillo
Carlos Rodriguez Del Castillo
The IEC 61850 standard has brought new opportunities for developing Centralized Substation Protection and Control (CPC) platforms to be used in digital substations. The CPC operation requires a proper signal processing module that provides the necessary parameters and signals accurately and at times needed to ensure the platform’s control and protection services can operate correctly. This paper proposes and implements a sampled values-analog processing module (SV-APM) for a software-based CPC in a digital substation developed in the framework of the EPICS project. The SV-APM decodes the digital messages published by merging units and extracts the information required by control and protection functions implemented in a software-based CPC platform. To check SV-APM performance, a set of tests is carried out using Real-time digital simulator (RTDS) and EPICS platform in Hardware in the Loop configuration (HiL). These tests evaluate SV-APM behavior against disturbances in communication channels, voltage and current variations, harmonic contents and frequency variations. Furthermore, latency tests are carried out to evaluate CPC response times. From tests, it is concluded that SV-APM output satisfactorily fulfills all the time response and accuracy requirements demanded during its development.

1 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Jose SaldanaJose Saldana
Jose Saldana
Aníbal Antonio Prada HurtadoAníbal Antonio Prada Hurtado
Aníbal Antonio Prada Hurtado
EMEduardo Martinez
Eduardo Martinez
YGYasmina Galve
Yasmina Galve
JTJesús Torres
Jesús Torres
WAMPAC (Wide Area Monitoring Protection and Control) applications are becoming crucial for granting a stable operation of the electricity transmission grid. These systems use a set of sensors distributed between different electrical substations to gather real-time measurements from the field. These sensors are called Phasor Measurement Units (PMUs). Using the gathered data, different monitoring, protection, and control algorithms are run in a Phasor Data Concentrator (PDC) located in a central location. These algorithms close the loop via the generation of remedial commands, which are sent back to the field level with stringent delay, security, and reliability requirements. GOOSE (Generic Object Oriented Substation Events) protocol, defined by IEC 61850 (IEC stands for International Electrotechnical Commission), is used for that aim and also considers the option of sending these commands over IP networks (this option is called Routed-GOOSE). The present article proposes two alternatives for the tunneling of GOOSE frames over IP. Both options allow the decoupling of the transmission and the security aspects, thus increasing flexibility and allowing for easier deployment. The first option, called VX-GOOSE, is a combination of standard protocols, allowing the sending of these frames over UDP/IP tunnels. The tests that have been carried out demonstrate that, under certain network conditions, the transmission of GOOSE frames over UDP may fail, and in some extreme cases, even a whole burst of GOOSEs could be lost. This may have very bad consequences for a distributed electrical system. It should be noted that this limitation affects both VX-GOOSE and Routed-GOOSE. To overcome these limitations, the second option, called Simplemux blast mode, includes a novel mechanism that provides delivery guarantees and a reduced delay, with the counterpart of a certain degree of redundancy. As shown in the experiments, the incurred delays can be significantly reduced when remote locations are connected via unreliable networks, whereas the bandwidth increase caused by redundancy can be kept at reasonable levels. Finally, it should be remarked that although GOOSE is a relevant example use case, this approach can be applied in other fields where flows require very low delay and delivery guarantees.

28 June 2021
Verified
Conference Paper
Closed access
Aníbal Antonio Prada HurtadoAníbal Antonio Prada Hurtado
Aníbal Antonio Prada Hurtado
ECEduardo Martínez Carrasco
Eduardo Martínez Carrasco
MMMaria Teresa Villén Martínez
Maria Teresa Villén Martínez
MMMiguel Ángel Oliván Monge
Miguel Ángel Oliván Monge
CDChristos N. Dikaiakos
Christos N. Dikaiakos
YKYusuf Zafer Korkmaz
Yusuf Zafer Korkmaz
In this paper, the capabilities of a Wide-Area Protection and Control (WAMPAC) lab-scale demonstration (DEMO) is presented. This lab will be used in Work Package 6 of H2020 FARCROSS Project for testing wide-area applications previously to their commissioning in a real DEMO in the Greek Transmission System. The capabilities of this lab-scaled DEMO are presented using the implementation of two different monitoring and protection applications for a proof of concepts. The first application is related to detection of inter-area power oscillations using PMU measurements and applying a remedial action. The second application deals with the comparison of the behavior of three line differential protection strategies: classical implementation using two fiber optic communicated relays, a solution based on values received from PMU and an algorithm receiving IEC 61850 Sampled Values and using open-source libraries in a common computer. These applications are tested by closing the loop using real protection and control hardware in the laboratory with an RTDS ™ simulator.

10 October 2022
Verified
Conference Paper
Closed access
KKKonstantinos F. Krommydas
Konstantinos F. Krommydas
CKChristos-Spyridon G. Karavas
Christos-Spyridon G. Karavas
KPKonstantinos A. Plakas
Konstantinos A. Plakas
DMDimitrios Melissaris
Dimitrios Melissaris
CDChristos N. Dikaiakos
Christos N. Dikaiakos
PCParis Chatzitheodorou
Paris Chatzitheodorou
The Greek power system is facing significant changes as the government’s policy is focused on an energy transition aligned with the European Union future plans by implementing comprehensive reforms in the energy sector to drive decarbonization, increase the share of renewable power plants and foster competitive markets. This transition is expected to create significant challenges to the operation of the future Greek power system. In this context, a Wide Area Monitoring, Protection and Control (WAMPAC) System is developed that is expected to serve as a useful tool for monitoring and controlling the steady and dynamic state of the power grid. Fifteen (15) time synchronized phasor measurement units are currently being installed in critical locations to gather data and online transmit them to phasor data concentrators in order to be used by the WAMPAC system. Moreover, a holistic design approach is adopted for the WAMPAC system with various protection and control services that aim to deal with the expected upcoming challenges. Overall, in this paper the developed augmented WAMPAC design approach and implementation is thoroughly described in order to serve as a roadmap for future power systems.