Antonio Casillas Zamora

Dr. Antonio Casillas Zamora

Departamento de Ingeniería de Proyectos, Centro Universitario de Ciencias Exactas e Ingenierías, Universidad de Guadalajara, Blvd- M. García Barragan 1421, Guadalajara, Jalisco, C. P. 44410, México
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2019 in Journal of Materials Science: Materials in Electronics
Verified
Journal Article
Closed access
PDF file
Antonio Casillas ZamoraAntonio Casillas Zamora
Antonio Casillas Zamora
JGJosé Trinidad Guillén-Bonilla
José Trinidad Guillén-Bonilla
AGAlex Guillén-Bonilla
Alex Guillén-Bonilla
MRM. Rodríguez-Betancourtt
M. Rodríguez-Betancourtt
YCY. L. Casallas-Moreno
Y. L. Casallas-Moreno
HBHéctor Guillén Bonilla
Héctor Guillén Bonilla

1 January 2021 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
JBJosé Trinidad Guillen Bonilla
José Trinidad Guillen Bonilla
HBHéctor Guillén Bonilla
Héctor Guillén Bonilla
Verónica-María Rodríguez-BetancourttVerónica-María Rodríguez-Betancourtt
Verónica-María Rodríguez-Betancourtt
ABAlex Guillén Bonilla
Alex Guillén Bonilla
Antonio Casillas ZamoraAntonio Casillas Zamora
Antonio Casillas Zamora
JRJorge Ramírez
Jorge Ramírez
A propane gas detector was built based on the semiconductor nickel antimonate oxide (NiSb2O6) by means of an analog electronic circuit. The gas detector was designed for monitoring atmospheres where the leakage of propane gas could possibly occur. The prototype’s construction methodology is presented in 5 stages: (1) synthesis of NiSb2O6 oxide powders, (2) characterization of the powders by XRD and TEM, (3) manufacture and electrical characterization of the chemical gas sensor, (4) design of the analog circuit based on the electrical response of the gas sensor, and (5) functionality tests. The gas detector was built at low cost and showed excellent functionality. The operating conditions were as follows: 200°C, gas concentration of 5 ppm, electronic circuit gain of 5, and sensor sensitivity of 0.41.

5 May 2018 in Journal of Materials Science: Materials in Electronics
Verified
Journal Article
Closed access
PDF file
ABAlex Guillén Bonilla
Alex Guillén Bonilla
Verónica-María Rodríguez-BetancourttVerónica-María Rodríguez-Betancourtt
Verónica-María Rodríguez-Betancourtt
HBHéctor Guillén Bonilla
Héctor Guillén Bonilla
LGLorenzo Gildo-Ortiz
Lorenzo Gildo-Ortiz
Oscar Blanco AlonsoOscar Blanco Alonso
Oscar Blanco Alonso
JBJosé Trinidad Guillen Bonilla
José Trinidad Guillen Bonilla

13 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
JBJosé Trinidad Guillen Bonilla
José Trinidad Guillen Bonilla
HBHéctor Guillen Bonilla
Héctor Guillen Bonilla
Verónica-María Rodríguez-BetancourttVerónica-María Rodríguez-Betancourtt
Verónica-María Rodríguez-Betancourtt
MSMaria Eugenia Sanchez
Maria Eugenia Sanchez
JRJuan Reyes-Gómez
Juan Reyes-Gómez
ABAlex Guillen Bonilla
Alex Guillen Bonilla
Interferometry sensors are frequently analyzed by applying the Fourier transform because the transformation separates all frequency components of its signal, making its study on a complex plane feasible. In this work, we study the relation between the optical path difference (OPD) and poles location theoretically and experimentally, using the Laplace transform and a pole-zero map. Theory and experiments are in concordance. For our study, only the cosine function was considered, which is filtered from the interference pattern. In experimental work, two unperturbed low-finesse Fabry–Pérot interferometers were used. First, a Fabry–Pérot interferometer that has a cavity length of ~ 1.6 mm was used. Its optical path difference was 2.33 mm and the poles were localized at points ± i 12 . rad/nm. Secondly, a Fabry–Pérot interferometer with a cavity length of ~ 5.2 mm was used, and its optical path difference was 7.59 mm and the poles were localized at points ± i 40.4 rad/nm. Experimental results confirmed the theoretical analysis. Our proposal finds practical application for interferometer analysis, signal processing of optical fiber sensors, communication system analysis, and multiplexing systems based on interferometers.

17 April 2023 in Journal of Materials Science: Materials in Electronics
Verified
Journal Article
Closed access
PDF file
JBJosé Trinidad Guillen Bonilla
José Trinidad Guillen Bonilla
ABAlex Guillen Bonilla
Alex Guillen Bonilla
Antonio Casillas ZamoraAntonio Casillas Zamora
Antonio Casillas Zamora
HBHéctor Guillén Bonilla
Héctor Guillén Bonilla

11 September 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JBJosé Trinidad Guillen Bonilla
José Trinidad Guillen Bonilla
HBHéctor Guillén Bonilla
Héctor Guillén Bonilla
Verónica-María Rodríguez-BetancourttVerónica-María Rodríguez-Betancourtt
Verónica-María Rodríguez-Betancourtt
Antonio Casillas ZamoraAntonio Casillas Zamora
Antonio Casillas Zamora
JRJorge Ramírez
Jorge Ramírez
ABAlex Guillén Bonilla
Alex Guillén Bonilla
Carbon monoxide (CO) is very toxic to health. CO gas can cause intoxication and even death when the concentration is high or there are long exposure times. To detect atmospheres with CO gas concentration detectors are placed. In this work, a novel CO detection device was proposed and applied for CO detection. For its implementation, four stages were developed: Synthesis of nickel antimonite (NiSb2O6) oxide powders, physical characterization of NiSb2O6 powders, Pellet fabrication and sensitivity test in CO atmospheres and electronic circuit implementation where signal adaptation and signal amplification were considered. Experimentally, a chemical sensor was built and characterized, its signal adaptation circuit was implemented and also it was proved using CO concentrations from 1 to 300 ppm with the operating temperatures of 100, 200, and 300 °C. Its optimal operation was at 300 °C. From the experimental results, the CO detection device had excellent functionality because the chemical sensor based on the nickel antimonite oxide had high sensitivity and good electrical response, whereas the DC electronic circuit had good performance.