Anuar Benjamín Beltrán González

Dr. Anuar Benjamín Beltrán González

Universidad de Guadalajara, Guadalajara, Jalisco, Mexico
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2017 in Applied Optics
Verified
Journal Article
Closed access
PDF file
BBBeethoven Bravo-Medina
Beethoven Bravo-Medina
MSMarija Strojnik
Marija Strojnik
Guillermo Garcia ToralesGuillermo Garcia Torales
Guillermo Garcia Torales
HTHector Torres-Ortega
Hector Torres-Ortega
RERuben Estrada-Marmolejo
Ruben Estrada-Marmolejo
JFJorge L. Flores
Jorge L. Flores
Risley prisms are widely used for beam pointing in several optical systems. The exact solution for the inverse problem does not exist, except using numerical methods. However, the errors introduced by misalignment are usually greater than the approximation errors. We present a novel method to compensate alignment errors in pointing systems based on Risley prisms. The prism model that we used is based on paraxial approximation with an additional vector to compensate typical alignment errors. Simulation and experimental results show that the improvement in pointing accuracy is achievable even in comparison with exact ray tracing methods.

16 May 2018 in Optical Engineering
Verified
Journal Article
Closed access
PDF file
AMAzael Mora-Núñez
Azael Mora-Núñez
GMGeminiano Martinez-Ponce
Geminiano Martinez-Ponce
Guillermo Garcia ToralesGuillermo Garcia Torales
Guillermo Garcia Torales
AGAnuar Benjamín Beltrán González
Anuar Benjamín Beltrán González
The imaging and digital processing of anisotropic optical properties of in vivo skin may be helpful in the assessment of its heterogeneous anatomy and physiological functioning. The interaction between polarized light and this organ provides information about the structural order beneath the epidermal layer. However, penetration depth is limited by optical absorption and scattering that are related to local skin characteristics such as pigment density, connective tissue organization, and cutaneous layer thickness. In this work, in vivo healthy skin of a murine model was analyzed using Mueller imaging polarimetry. A gray-level co-occurrence matrix analysis of diattenuation, birefringence, and depolarization measures in four different skin locations showed texture properties that can be used to distinguish local physiology.

1 August 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Marija StrojnikMarija Strojnik
Marija Strojnik
BBBeethoven Bravo-Medina
Beethoven Bravo-Medina
AGAnuar Benjamín Beltrán González
Anuar Benjamín Beltrán González
YWYaujen Wang
Yaujen Wang
The off-axis three-mirror optical system is derived from the classical Cooke triplet or a derivative of the inverse-telephoto lens. By properly arranging an internal reimaging mechanism or altering the location of the optical stop, one can create different versions of three-mirror optical systems. They include very compact configurations and wide field-of-view imagers. Insights into the optical design process, manufacturing, stray light management, and remote sensing applications are presented.

31 October 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Guillermo Garcia ToralesGuillermo Garcia Torales
Guillermo Garcia Torales
HOHector Hugo Torres Ortega
Hector Hugo Torres Ortega
RMRUBEN ESTRADA MARMOLEJO
RUBEN ESTRADA MARMOLEJO
AGAnuar Benjamín Beltrán González
Anuar Benjamín Beltrán González
Marija StrojnikMarija Strojnik
Marija Strojnik
Loop-Mediated Isothermal Loop-Mediated Isothermal Amplification (LAMP) is a widely used technique for nucleic acid amplification due to its high specificity, sensitivity, and rapid results. Advances in microfluidic lab-on-chip (LOC) technology have enabled the integration of LAMP into miniaturized devices, known as μ-LAMP, which require precise thermal control for optimal DNA amplification. This paper introduces a novel thermal bed design using PCB copper traces and FR−4 dielectric materials, providing a reliable, modular, and repairable heating platform. The system achieves accurate and stable temperature control, which is critical for μ-LAMP applications, with temperature deviations within ±1.0 °C. The thermal bed’s performance is validated through finite element method (FEM) simulations, showing uniform temperature distribution and a rapid thermal response of 2.5 s to reach the target temperature. These results highlight the system’s potential for applications such as disease diagnostics, biological safety, and forensic analysis, where precision and reliability are paramount.

14 September 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Guillermo Garcia ToralesGuillermo Garcia Torales
Guillermo Garcia Torales
HTH. Torres-Ortega
H. Torres-Ortega
RMRUBEN ESTRADA MARMOLEJO
RUBEN ESTRADA MARMOLEJO
AGAnuar Benjamín Beltrán González
Anuar Benjamín Beltrán González
Marija StrojnikMarija Strojnik
Marija Strojnik
Loop-Mediated Isothermal Amplification (LAMP) is a widely used technique for nucleic acid amplification due to its high specificity, sensitivity, and rapid results. Advances in microfluidic lab-on-chip (LOC) technology have enabled the integration of LAMP into miniaturized devices, known as μ-LAMP, which require precise thermal control for optimal DNA amplification. This paper introduces a novel thermal bed design using PCB copper traces and FR−4 dielectric materials, providing a reliable, modular, and repairable heating platform. We present the design, fabrication, and control mechanisms of the thermal bed, demonstrating its ability to maintain accurate temperatures essential for μ-LAMP applications. The thermal bed’s performance is validated through finite element method (FEM) simulations, confirming its effectiveness in diverse applications such as disease diagnostics, biological safety, and forensic analysis.

7 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
HSHECTOR SANTIAGO-HERNANDEZ
HECTOR SANTIAGO-HERNANDEZ
AGAnuar Benjamín Beltrán González
Anuar Benjamín Beltrán González
AMAzael Jesus Mora
Azael Jesus Mora
BBBeethoven Bravo-Medina
Beethoven Bravo-Medina
OPOLIVIER JEAN MICHEL POTTIEZ
OLIVIER JEAN MICHEL POTTIEZ
In this work, we study a double-sense twisted low-birefringence Sagnac loop structure as a sound/vibration sensing device. We study the relation between the adjustments of a wave retarder inside the loop (which allows controlling the transmission characteristic to deliver 10, 100, and 300 μW average power at the output of the system) and the response of the Sagnac sensor to vibration frequencies ranging from 0 to 22 kHz. For a 300 m loop Sagnac, two sets of experiments were carried out, playing at the same time all the sound frequencies mixed for ∼1 s, and playing a sweep of frequencies for 30 s. In both cases, the time- and frequency-domain transmission amplitudes are larger for an average power of 10 μW, and smaller for an average power of 300 μW. For mixed frequencies, the Fourier analysis shows that the Sagnac response is larger for low frequencies (from 0 to ∼5 kHz) than for high frequencies (from ∼5 kHz to ∼22 kHz). For a sweep of frequencies, the results reveal that the interferometer perceives all frequencies. However, beyond ∼2.5 kHz, harmonics are present each ∼50 Hz, revealing that some resonances are present. The results about the influence of the power transmission through the polarizer and power emission of laser diode (LD) on the Sagnac interferometer response at high frequencies reveal that our system is robust, and the results are highly reproducible, and harmonics do not depend on the state of polarization at the input of the Sagnac interferometer. Furthermore, increasing the LD output power from 5 mW to 67.5 mW allows us to eliminate noisy signals at the system output. in our setup, the minimum sound level detected was 56 dB. On the other hand, the experimental results of a 10 m loop OFSI reveal that the response at low frequencies (1.5 kHz to 5 kHz) is minor compared with the 300 m loop OFSI. However, the response at high frequencies is low but still enables the detection of these frequencies, yielding the possibility of tuning the response of the vibration sensor by varying the length of the Sagnac loop.