Armin M. Scholz

Prof. Dr. Armin M. Scholz

Veterinary Faculty, Ludwig-Maximilians-Universität München, Munich, Bavaria, Germany
orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Animal
Verified
Journal Article
Open access
Armin M. ScholzArmin M. Scholz
Armin M. Scholz
LBL. Bünger
L. Bünger
JKJ. Kongsro
J. Kongsro
UBU. Baulain
U. Baulain
AMA.D. Mitchell
A.D. Mitchell
The ability to accurately measure body or carcass composition is important for performance testing, grading and finally selection or payment of meat-producing animals. Advances especially in non-invasive techniques are mainly based on the development of electronic and computer-driven methods in order to provide objective phenotypic data. The preference for a specific technique depends on the target animal species or carcass, combined with technical and practical aspects such as accuracy, reliability, cost, portability, speed, ease of use, safety and for in vivo measurements the need for fixation or sedation. The techniques rely on specific device-driven signals, which interact with tissues in the body or carcass at the atomic or molecular level, resulting in secondary or attenuated signals detected by the instruments and analyzed quantitatively. The electromagnetic signal produced by the instrument may originate from mechanical energy such as sound waves (ultrasound - US), 'photon' radiation (X-ray-computed tomography - CT, dual-energy X-ray absorptiometry - DXA) or radio frequency waves (magnetic resonance imaging - MRI). The signals detected by the corresponding instruments are processed to measure, for example, tissue depths, areas, volumes or distributions of fat, muscle (water, protein) and partly bone or bone mineral. Among the above techniques, CT is the most accurate one followed by MRI and DXA, whereas US can be used for all sizes of farm animal species even under field conditions. CT, MRI and US can provide volume data, whereas only DXA delivers immediate whole-body composition results without (2D) image manipulation. A combination of simple US and more expensive CT, MRI or DXA might be applied for farm animal selection programs in a stepwise approach.

1 March 2015 in Molecular & Cellular Proteomics
Verified
Journal Article
Open access
PDF file
BTBjoern Traenkle
Bjoern Traenkle
FEFelix Emele
Felix Emele
RARoman Anton
Roman Anton
OPOliver Poetz
Oliver Poetz
RHRagna S. Haeussler
Ragna S. Haeussler
Ulrich RothbauerUlrich Rothbauer
Ulrich Rothbauer
β-catenin is the key component of the canonical Wnt pathway and plays a crucial role in a multitude of developmental and homeostatic processes. The different tasks of β-catenin are orchestrated by its subcellular localization and participation in multiprotein complexes. To gain a better understanding of β-catenin9s role in living cells we have generated a new set of single domain antibodies, referred to as nanobodies, derived from heavy chain antibodies of camelids. We selected nanobodies recognizing the N-terminal, core or C-terminal domain of β-catenin and applied these new high-affinity binders as capture molecules in sandwich immunoassays and co-immunoprecipitations of endogenous β-catenin complexes. In addition, we engineered intracellularly functional anti-β-catenin chromobodies by combining the binding moieties of the nanobodies with fluorescent proteins. For the first time, we were able to visualize the subcellular localization and nuclear translocation of endogenous β-catenin in living cells using these chromobodies. Moreover, the chromobody signal allowed us to trace the accumulation of diffusible, hypo-phosphorylated β-catenin in response to compound treatment in real time using High Content Imaging. The anti-β-catenin nanobodies and chromobodies characterized in this study are versatile tools that enable a novel and unique approach to monitor the dynamics of subcellular β-catenin in biochemical and cell biological assays.

1 May 2018 in Molecular Metabolism
Verified
Journal Article
Open access
AHArne Hinrichs
Arne Hinrichs
BKBarbara Kessler
Barbara Kessler
MKMayuko Kurome
Mayuko Kurome
ABAndreas Blutke
Andreas Blutke
EKElisabeth Kemter
Elisabeth Kemter
EWEckhard Wolf
Eckhard Wolf
Laron syndrome (LS) is a rare, autosomal recessive disorder in humans caused by loss-of-function mutations of the growth hormone receptor (GHR) gene. To establish a large animal model for LS, pigs with GHR knockout (KO) mutations were generated and characterized. CRISPR/Cas9 technology was applied to mutate exon 3 of the GHR gene in porcine zygotes. Two heterozygous founder sows with a 1-bp or 7-bp insertion in GHR exon 3 were obtained, and their heterozygous F1 offspring were intercrossed to produce GHR-KO, heterozygous GHR mutant, and wild-type pigs. Since the latter two groups were not significantly different in any parameter investigated, they were pooled as the GHR expressing control group. The characterization program included body and organ growth, body composition, endocrine and clinical-chemical parameters, as well as signaling studies in liver tissue. GHR-KO pigs lacked GHR and had markedly reduced serum insulin-like growth factor 1 (IGF1) levels and reduced IGF-binding protein 3 (IGFBP3) activity but increased IGFBP2 levels. Serum GH concentrations were significantly elevated compared with control pigs. GHR-KO pigs had a normal birth weight. Growth retardation became significant at the age of five weeks. At the age of six months, the body weight of GHR-KO pigs was reduced by 60% compared with controls. Most organ weights of GHR-KO pigs were reduced proportionally to body weight. However, the weights of liver, kidneys, and heart were disproportionately reduced, while the relative brain weight was almost doubled. GHR-KO pigs had a markedly increased percentage of total body fat relative to body weight and displayed transient juvenile hypoglycemia along with decreased serum triglyceride and cholesterol levels. Analysis of insulin receptor related signaling in the liver of adult fasted pigs revealed increased phosphorylation of IRS1 and PI3K. In agreement with the loss of GHR, phosphorylation of STAT5 was significantly reduced. In contrast, phosphorylation of JAK2 was significantly increased, possibly due to the increased serum leptin levels and increased hepatic leptin receptor expression and activation in GHR-KO pigs. In addition, increased mTOR phosphorylation was observed in GHR-KO liver samples, and phosphorylation studies of downstream substrates suggested the activation of mainly mTOR complex 2. GHR-KO pigs resemble the pathophysiology of LS and are an interesting model for mechanistic studies and treatment trials.

1 January 2001 in Journal of Animal Science
Verified
Journal Article
Closed access
PDF file
AMA. D. Mitchell
A. D. Mitchell
Armin M. ScholzArmin M. Scholz
Armin M. Scholz
PWP. C. Wange
P. C. Wange
HSH. Song
H. Song
Magnetic resonance imaging (MRI) was used to measure, in vivo, the volume of several organs and tissues of a total of 111 pigs (males and females) ranging in BW from 6.1 to 97.2 kg. In one experiment the in vivo MRI volumes were compared to tissue or organ weights obtained by dissection. For internal organs, the correlation (R2) between MRI volume and dissected weight ranged from 0.64 (SE of estimation = 65 g) for the heart to 0.90 (SE of estimation = 125 g) for the liver. The MRI volume of the kidneys was approximately 10% less than the dissected weight, whereas the MRI volumes of the heart, liver, and brain exceeded the weights of dissected organs by 13, 17, and 26%, respectively. For fat and muscle tissues, the correlation between MRI volume and dissected weight ranged from 0.82 (psoas muscle) to 0.97 (total right ham muscles). The MRI volume of the backfat and shoulder muscles exceeded the dissected weights by approximately 2%, whereas the MRI volumes of the ham muscles, jowl fat, longissimus muscle, and psoas muscle were 2, 8, 18 and 20% less than their respective weights. In another series of experiments, MRI volume measurements of fat and muscle regions (Jowl fat, backfat, shoulder muscles, LD muscles, psoas muscles, ham muscles, a 10-cm section of the longissimus muscles and overlying fat, and a 15-cm section of the ham muscles and overlying fat) were evaluated by stepwise regression for the prediction of total body fat, lean, and protein. The best prediction of percentage total body fat was obtained using the fat volume from the 10-cm section of longissimus muscle and the fat:muscle ratio from the 15-cm section of the ham (R2 = 0.9). The best prediction of percentage total body protein was obtained using a combination of the volumes (as a percentage of BW) of jowl fat, backfat, shoulder muscle, and ham muscle (R2 = 0.62). The combination fat volume from the 10-cm section of longissimus muscle, the fat:muscle ratio from the 15-cm section of the ham, and the lean volume percentage from the 15-cm section of ham provided the best prediction of the percentage of total body lean (R2 = 0.88).

28 November 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JHJonas Helma
Jonas Helma
KSKatrin Schmidthals
Katrin Schmidthals
VLVanda Lux
Vanda Lux
SNStefan Nüske
Stefan Nüske
Armin M. ScholzArmin M. Scholz
Armin M. Scholz
HLHeinrich Leonhardt
Heinrich Leonhardt
In basic and applied HIV research, reliable detection of viral components is crucial to monitor progression of infection. While it is routine to detect structural viral proteins in vitro for diagnostic purposes, it previously remained impossible to directly and dynamically visualize HIV in living cells without genetic modification of the virus. Here, we describe a novel fluorescent biosensor to dynamically trace HIV-1 morphogenesis in living cells. We generated a camelid single domain antibody that specifically binds the HIV-1 capsid protein (CA) at subnanomolar affinity and fused it to fluorescent proteins. The resulting fluorescent chromobody specifically recognizes the CA-harbouring HIV-1 Gag precursor protein in living cells and is applicable in various advanced light microscopy systems. Confocal live cell microscopy and super-resolution microscopy allowed detection and dynamic tracing of individual virion assemblies at the plasma membrane. The analysis of subcellular binding kinetics showed cytoplasmic antigen recognition and incorporation into virion assembly sites. Finally, we demonstrate the use of this new reporter in automated image analysis, providing a robust tool for cell-based HIV research.

27 April 2021 in EMBO Reports
Verified
Journal Article
Open access
PDF file
TWTeresa R. Wagner
Teresa R. Wagner
EOElena Ostertag
Elena Ostertag
PKPhilipp D Kaiser
Philipp D Kaiser
MGMarius Gramlich
Marius Gramlich
NRNatalia Ruetalo
Natalia Ruetalo
Ulrich RothbauerUlrich Rothbauer
Ulrich Rothbauer
In light of the COVID-19 pandemic, there is an ongoing need for diagnostic tools to monitor the immune status of large patient cohorts and the effectiveness of vaccination campaigns. Here, we present 11 unique nanobodies (Nbs) specific for the SARS-CoV-2 spike receptor-binding domain (RBD), of which 8 Nbs potently inhibit the interaction of RBD with angiotensin-converting enzyme 2 (ACE2) as the major viral docking site. Following detailed epitope mapping and structural analysis, we select two inhibitory Nbs, one of which binds an epitope inside and one of which binds an epitope outside the RBD:ACE2 interface. Based on these, we generate a biparatopic nanobody (bipNb) with viral neutralization efficacy in the picomolar range. Using bipNb as a surrogate, we establish a competitive multiplex binding assay (“NeutrobodyPlex”) for detailed analysis of the presence and performance of neutralizing RBD-binding antibodies in serum of convalescent or vaccinated patients. We demonstrate that NeutrobodyPlex enables high-throughput screening and detailed analysis of neutralizing immune responses in infected or vaccinated individuals, to monitor immune status or to guide vaccine design.