Arslan Ahmed Amin

Dr. Arslan Ahmed Amin

National University of Computer and Emerging Sciences, Faisalabad, Punjab, Pakistan
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Measurement
Verified
Journal Article
Closed access
AAArslan Ahmed Amin
Arslan Ahmed Amin
KHKhalid Mahmood Hasan
Khalid Mahmood Hasan

16 November 2020 in IEEE Access
Verified
Journal Article
Open access
SYShaharyar Yousaf
Shaharyar Yousaf
AMAbdullah Mughees
Abdullah Mughees
MKMuhammad Gufran Gufran Khan
Muhammad Gufran Gufran Khan
AAArslan Ahmed Amin
Arslan Ahmed Amin
MAMuhammad Adnan
Muhammad Adnan
A nano-grid is an independent hybrid sustainable framework that utilizes non-renewable and renewable power resources for supplying continuous electrical energy to the load. Considering this scenario, in this research work, photovoltaic (PV) array, wind turbine, and fuel cell are taken as the three generation resources that have been used in the nano-grid. The active and reactive power of the all three generation resources is controlled using various controllers, i.e. integral, proportional-integral, proportional derivative, proportional integral derivative, fractional-order proportional-integral, fractional order proportional integral derivative (FOPID) and sliding mode controller (SMC). An advanced optimization technique based on a genetic algorithm (GA) and particle swarm optimization (PSO) algorithm has been utilized to optimize all of these controllers. The integral square error is taken as the objective function for both optimization algorithms. Finally, a graphical and tabular comparative analysis of all optimized controllers along with their control parameters and performance indexes is evaluated to find the best optimal solution. The performance of SMC has surpassed the performance of all other optimized controllers for power stability. In less than 0.267 seconds, the actual power yielded by using SMC is within 1% of the desired power. PSO algorithm has performed better than GA algorithm with all controllers. The worst performance is by FOPID controller with a steady state error of 6071.3W using GA algorithm and have a high magnitude of overshoot and undershoot. Moreover, a smart switching algorithm has been introduced for switching between the generation resources in accordance with the load demand and cost of the system in order to operate the nano-grid more economically. Finally, a case study has been performed in which the smart switching algorithm is utilized to switch to the best available generation resource in case of any fault at the generation side to provide uninterrupted power to the attached loads.

31 October 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
TATurki mohammed alsuwian
Turki mohammed alsuwian
ABAiman Shahid Butt
Aiman Shahid Butt
AAArslan Ahmed Amin
Arslan Ahmed Amin
The incorporation of communication technology with Smart Grid (SG) is proposed as an optimal solution to fulfill the requirements of the modern power system. A smart grid integrates multiple energy sources or microgrids and is supported by an extensive control and communication network using the Internet of Things (IoT) for a carbon-free, more reliable, and intelligent energy system. Along with many benefits, the system faces novel security challenges, data management, integration, and interoperability challenges. The advanced control and communication network in the smart grid is susceptible to cyber and cyber-physical threats. A lot of research has been done to improve the cyber security of the smart grid. This review aims to provide an overview of the types of cyber security threats present for smart grids with an insight into strategies to overcome the challenges. As the selection of techniques and technologies may vary according to the threats faced, therefore the adoption of researched methods is compared and discussed. As cyber-security is the greatest challenge in smart grid implementation, this review is beneficial during the planning and operation of smart grids for enhanced security.

27 February 2024 in Measurement and Control
Verified
Journal Article
Open access
MYMuhammad Yousuf
Muhammad Yousuf
TATurki Alsuwian
Turki Alsuwian
AAArslan Ahmed Amin
Arslan Ahmed Amin
SFSanwal Fareed
Sanwal Fareed
MHMuhammad Hamza
Muhammad Hamza
This research paper presents the development and implementation of an integrated condition monitoring and fault detection system for AC induction motors using a combination of sensors, GSM communication, and a cloud-based Internet of Things (IoT) platform. The proposed system aims to enhance industrial motors’ operational reliability and efficiency by providing real-time data monitoring and early fault detection. The key components of the system include temperature, vibration, current, voltage, and speed sensors, which are strategically placed to gather critical motor performance data. These sensors feed data to an Arduino-based control unit responsible for sensor data acquisition and processing. To ensure timely response to anomalies, the system is equipped with an alarm system and GSM alerts, which notify designated personnel in case of abnormal motor behavior. Moreover, the paper incorporates remote monitoring capabilities, enabling users to access motor health data and real-time status from a distance. Historical data is also stored for analysis and comparison through the integration of a cloud-based Blynk-IoT platform. Additionally, the system facilitates RPM control and utilizes relay modules for seamless motor control and protection. The proposed system was tested and validated using Proteus for circuit diagram simulation and Arduino for sensor coding. The results demonstrate its effectiveness in detecting abnormal motor behavior and its potential to prevent catastrophic failures by enabling predictive maintenance. The proposed system successfully detects and displays abnormalities in important parameters like vibration, temperature, speed, three-phase currents, and voltages with 99% accuracy.

17 April 2019 in Measurement and Control
Verified
Journal Article
Open access
PDF file
AAArslan Ahmed Amin
Arslan Ahmed Amin
KMKhalid Mahmood-Ul-Hasan
Khalid Mahmood-Ul-Hasan
In this paper, a hybrid fault tolerant control system is proposed for air–fuel ratio control of internal combustion gasoline engines based on Kalman filters and triple modular redundancy. Hybrid fault tolerant control system possesses properties of both active fault tolerant control system and passive fault tolerant control system. As part of active fault tolerant control system, fault detection and isolation unit is designed using Kalman filters to provide estimated values of the sensors to the engine controller in case of faults in the sensors. As part of passive fault tolerant control system, a dedicated proportional–integral feedback controller is incorporated to maintain air–fuel ratio by adjusting the throttle actuator in the fuel supply line in faulty and noisy conditions for robustness to faults and sensors’ noise. Redundancy is proposed in the sensors and actuators as a simultaneous failure of more than one sensor, and failure of the single actuator will cause the engine shutdown. Advanced redundancy protocol triple modular redundancy is proposed for the sensors and dual redundancy is proposed for actuators. Simulation results in the MATLAB Simulink environment show that the proposed system remains stable during faults in the sensors and actuators. It also maintains air–fuel ratio without any degradation in the faulty conditions and is robust to noise. Finally, the probabilistic reliability analysis of the proposed model is carried out. The study shows that the proposed hybrid fault tolerant control system with redundant components presents a novel and highly reliable solution for the air–fuel ratio control in internal combustion engines to prevent engine shutdown and production loss for greater profits.

24 August 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TATurki mohammed alsuwian
Turki mohammed alsuwian
RSRana Basharat Saeed
Rana Basharat Saeed
AAArslan Ahmed Amin
Arslan Ahmed Amin
The automobile revolution and growth in the number of cars produced several issues, and vehicle accidents remain one of the most serious road-related issues. Human mistakes and a failure to brake quickly are the main causes of accidents. There may be serious outcomes to driving when distracted. To address the aforementioned issues, an autonomous emergency braking system (AEBS) was developed. To support such an AEBS, scalable, reliable, secure, fault-tolerant, and interoperable technologies are required. An advanced emergency braking system (EBS) with sensor fusion is proposed in this paper that can autonomously identify a probable forward collision and activate the vehicle braking system to brake the vehicle to avoid or mitigate a collision. Additionally, it provides a non-linear speed controller that facilitates the AEBS to apply the brakes in an emergency. Sensor fusion using lidar, radar, and vision sensors makes the AEBS more efficient and more reliable to detect vehicles or obstacles and decreases the chance of collision to a minimum level. A MATLAB/Simulink environment was used for simulation experiments and the results demonstrated the stable operation of the AEBS to avoid forward collisions in the event of an error in the measurement of any one sensor while any vehicle is detected. The presented work establishes that the EBS sensor fusion unit is a highly reliable solution for detecting the leading vehicle at the proper time and the AEBS controller can apply the brake in the situation of forwarding obstacle detection.