Aruzhan Imasheva

Ms. Aruzhan Imasheva

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2025 in IEEE Access
Verified
Journal Article
Open access
BABeibit Abdikenov
Beibit Abdikenov
TZTomiris Zhaksylyk
Tomiris Zhaksylyk
OSOlzhas Shortanbaiuly
Olzhas Shortanbaiuly
YOYerzhan Orazayev
Yerzhan Orazayev
NMNursultan Makhanov
Nursultan Makhanov
ASAigerim Seitova
Aigerim Seitova
Breast cancer diagnosis has greatly benefited from the use of deep learning (DL) and machine learning (ML) methods on multimodal data, including mammography, magnetic resonance imaging (MRI), ultrasound, histopathology, genomic data, and clinical reports. Every modality presents its challenges and opportunities, demanding a thorough understanding of used methods for accurate and early diagnosis. Our review provides an exhaustive survey of the latest advances in DL and ML applications to detect, classify, and segment breast cancer in these modalities. Our work also addresses basic issues of data limitations, model generalizability, and interpretability. To overcome these issues we explore the state-of-the-art Vision-Language Models (VLMs) as an emerging approach for multimodal learning. Through incorporation of the current advances and identification of areas of future improvement, this review is a precious source of information to researchers and practitioners. The findings highlight the importance of interdisciplinary collaboration, application of standardized data sets, and continuous improvement of the methodology to facilitate clinical uptake of AI-based breast cancer diagnostic systems.

22 July 2025 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
BABeibit Abdikenov
Beibit Abdikenov
TZTomiris Zhaksylyk
Tomiris Zhaksylyk
AIAruzhan Imasheva
Aruzhan Imasheva
YOYerzhan Orazayev
Yerzhan Orazayev
TKTemirlan Karibekov
Temirlan Karibekov
Mammography is the main method for early detection of breast cancer, which is still a major global health concern. However, inter-reader variability and the inherent difficulty of interpreting subtle radiographic features frequently limit the accuracy of diagnosis. A thorough assessment of deep convolutional neural networks (CNNs) for automated mammogram classification is presented in this work, along with the introduction of two innovative multi-view integration techniques: Dual-Branch Ensemble (DBE) and Merged Dual-View (MDV). By setting aside two datasets for out-of-sample testing, we evaluate the generalizability of the model using six different mammography datasets that represent various populations and imaging systems. We compare a number of cutting-edge architectures on both individual and combined datasets, including ResNet, DenseNet, EfficientNet, MobileNet, Vision Transformers, and VGG19. Both MDV and DBE strategies improve classification performance, according to experimental results. VGG19 and DenseNet both obtained high ROC AUC scores of 0.9051 and 0.7960 under the MDV approach. DenseNet demonstrated strong performance in the DBE setting, achieving a ROC AUC of 0.8033, while ResNet50 recorded a ROC AUC of 0.8042. These enhancements demonstrate how beneficial multi-view fusion is for boosting model robustness. The impact of domain shift is further highlighted by generalization tests, which emphasize the need for diverse datasets in training. These results offer practical advice for improving CNN architectures and integration tactics, which will aid in the creation of trustworthy, broadly applicable AI-assisted breast cancer screening tools.

2 October 2025 in Informatics
Verified
Journal Article
Open access
PDF file
BABeibit Abdikenov
Beibit Abdikenov
TZTomiris Zhaksylyk
Tomiris Zhaksylyk
AIAruzhan Imasheva
Aruzhan Imasheva
DRDimash Rakishev
Dimash Rakishev
Breast cancer is one of the main causes of cancer-related death for women worldwide, and enhancing patient outcomes still depends on early detection. The most common imaging technique for diagnosing and screening for breast cancer is mammography, which has a high potential for early lesion detection. With an emphasis on the incorporation of deep learning (DL) techniques, this review examines the changing role of mammography in early breast cancer detection. We examine recent advancements in DL-based approaches for mammogram analysis, including tasks such as classification, segmentation, and lesion detection. Additionally, we assess the limitations of traditional mammographic methods and highlight how DL can enhance diagnostic accuracy, reduce false positives and negatives, and support clinical decision-making. The review emphasizes the potential of DL to assist radiologists in clinical decision-making, as well as increases in diagnostic accuracy and decreases in false positives and negatives. We also discuss issues like interpretability, generalization across populations, and data scarcity. This review summarizes the available data to highlight the revolutionary potential of DL-enhanced mammography in breast cancer screening and to suggest future research avenues for more reliable, transparent, and clinically useful AI-driven solutions.

28 September 2026 in Information
Verified
Journal Article
Open access
PDF file
BABeibit Abdikenov
Beibit Abdikenov
AIAruzhan Imasheva
Aruzhan Imasheva
DIDauren Izdibay
Dauren Izdibay
TZTomiris Zhaksylyk
Tomiris Zhaksylyk
Background: Public breast ultrasound datasets are assembled around lesions. Of eight sources examined here, five contain no normal images, and under leave-one-dataset-out evaluation, the normal class is therefore almost perfectly confounded with the acquisition source: with one site held out, 356 of the 358 normal training images come from a single other source, supplied by 28 of that source’s 38 patients. Methods: We evaluated normal-versus-abnormal classification across eight public datasets with splits disjoint in the grouping identifier that each source supplies, two architectures and ten seeds per cell, treating the seed as the unit of analysis and comparing arms paired by seed. Seven interventions were compared: loss reweighting; balanced sampling; focal loss; class-balanced loss; and three variants of Mosaic, a patch substitution scheme that replaces annotated lesions with real non-lesion tissue. Results: Baseline models attained a mean area under the curve of 0.820 on held-out sites while assigning almost every image to the abnormal class (specificity 0.052 at threshold 0.5; 33 of 40 runs below 0.05). Validation area under the curve was 0.997, so epoch and threshold selection chose among near-ties, and identical reruns differed by 0.204 in specificity at the validation-selected threshold. A threshold set for 95% validation sensitivity delivered 74–92% on held-out sites. Subsampling the normal training images to 10% changed nothing, suggesting that volume is not the binding constraint and consistent with a role for source diversity. Only patch substitution improved the operating point, moving the mean specificity at threshold 0.5 from 0.052 to 0.235 and the expected calibration error from 0.348 to 0.234. Conclusions: In this setting, an operating point is not a property of the method, and results should be reported at a declared fixed threshold with per-seed variability.

30 September 2026 in Scientific Journal of Astana IT University
Verified
Journal Article
Open access
PDF file
BABeibit Abdikenov
Beibit Abdikenov
AIAruzhan Imasheva
Aruzhan Imasheva
TZTomiris Zhaksylyk
Tomiris Zhaksylyk
Screening mammography is read comparatively: radiologists hold one breast against the other, and several finding categories have no meaning outside that comparison. Most automated pipelines nonetheless encode a single breast at a time. We describe Bilateral MV-CLIP, a contrastive image-text framework in which all four projections of a patient enter one forward pass and the two lateralities exchange information through a Cross-Lateral Attention block, with a learned gate and a placeholder token preserving behaviour when a projection or an entire side is unavailable. Training combines image-text and image-image objectives, graded similarity targets, and a symmetry term tying embedding geometry to recorded asymmetry status. We train on VinDr-Mammo with reports synthesised from structured annotations and evaluate by linear probing of frozen features, cross-modal retrieval and report decoding, against an independently trained single-breast model matched in backbone, optimiser, schedule and epoch budget, with checkpoints selected on a held-out validation partition. On a pre-specified composite endpoint pooling the three comparison-defined categories, fusion did not improve on that baseline: area under the curve 0.781 against 0.792, a difference of -1.1 points with a 95% confidence interval from -9.6 to +7.5. Per-category effects follow the direction the design predicts, but the partition holds 49 positive comparison-defined breasts and no difference survived correction. Retrieval is limited by weak instance-level image-text alignment rather than by report redundancy, with a pool-size-independent ranking accuracy of 0.691. On an external cohort of 11,913 patients labelled by biopsy the representations transfer at reduced discrimination, reaching 0.65 for any abnormality. We therefore report explicit bilateral comparison as plausible but, on this dataset, unconfirmed, and give confidence intervals throughout.

23 November 2025 in Journal of Clinical Medicine of Kazakhstan
Verified
Journal Article
Open access
BABeibit Abdikenov
Beibit Abdikenov
NSNurbek Saidnassim
Nurbek Saidnassim
BABirzhan Ayanbayev
Birzhan Ayanbayev
AIAruzhan Imasheva
Aruzhan Imasheva
Background: Breast cancer remains one of the leading causes of cancer-related deaths among women globally. Early detection through mammographic screening significantly improves survival rates, but the interpretation of mammograms is time-consuming and requires extensive expertise. Methods: We utilized six publicly available datasets, preprocessing paired craniocaudal (CC) and mediolateral oblique (MLO) views into dual-view concatenated images. Three vision-language models (VLMs)—Quantized Qwen2-VL-2B, Quantized SmolVLM (Idefics3-based), and MammoCLIP—were evaluated using two adaptation strategies: full supervised fine-tuning (SFT) and Linear Probing (LP). EfficientNet-B4 served as a CNN baseline. Results: Experiments show that while EfficientNet-B4 achieved the highest F1-score (0.5810), VLMs delivered competitive results with additional report generation capability. MammoCLIP exhibited the best VLM performance (F1 = 0.4755, ROC-AUC = 0.6906) under LP, outperforming general-purpose VLMs, which struggled with recall despite high precision. SmolVLM demonstrated balanced performance under full fine-tuning (F1 = 0.5101, ROC-AUC = 0.6304), indicating strong adaptability in resource-efficient setups. Conclusion: These findings highlight that domain-specific pretraining significantly enhances VLM effectiveness in mammography classification. Beyond classification, VLMs enable structured reporting and interactive decision support, offering promising avenues for clinical integration despite slightly lower predictive performance compared to specialized CNNs.