Ashfaq Ahmad

Mr. Ashfaq Ahmad

Ultrasound Medicine, Huazhong University of Science and Technology, Wuhan, Hubei, China
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
Ashfaq AhmadAshfaq Ahmad
Ashfaq Ahmad
HLHe Li
He Li
YZYanting Zhang
Yanting Zhang
JLJuanjuan Liu
Juanjuan Liu
YGYing Gao
Ying Gao
Mingxing XieMingxing Xie
Mingxing Xie
Right ventricular (RV) function has important prognostic value in a variety of cardiovascular diseases. Due to complex anatomy and mode of contractility, conventional two-dimensional echocardiography does not provide sufficient and accurate RV function assessment. Currently, three-dimensional echocardiography (3DE) allows for an excellent and reproducible assessment of RV function owing to overcoming these limitations of traditional echocardiography. This review focused on 3DE and discussed the following points: (i) acquisition of RV dataset for 3DE images, (ii) reliability, feasibility, and reproducibility of RV volumes and function measured by 3DE with different modalities, (iii) the clinical application of 3DE for RV function quantification.

21 October 2021 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
Ashfaq AhmadAshfaq Ahmad
Ashfaq Ahmad
HLHe Li
He Li
XWXiaojing Wan
Xiaojing Wan
YZYi Zhong
Yi Zhong
YZYanting Zhang
Yanting Zhang
Mingxing XieMingxing Xie
Mingxing Xie
Background: A novel, fully automated right ventricular (RV) software for three-dimensional quantification of RV volumes and function was developed. The direct comparison of the software performance with cardiac magnetic resonance (CMR) was limited. Therefore, the aim of this study was to test the feasibility, accuracy, and reproducibility of a fully automated RV quantification software against CMR imaging as a reference.Methods: A total of 170 patients who underwent both CMR and three-dimensional echocardiography were enrolled. RV end-diastolic volume (RVEDV), RV end-systolic volume (RVESV), and RV ejection fraction (RVEF) were obtained using fully automated three-dimensional RV quantification software and compared with a CMR reference. For inter-technical agreement, Spearman correlation and Bland–Altman analysis were used.Results: The fully automated RV quantification software was feasible in 149 patients. RVEDV and RVESV were underestimated, and RVEF was overestimated compared with CMR values. RV measurements obtained from the manual editing method correlated better with CMR values than that without manual editing (RVEDV, 0.924 vs. 0.794: RVESV, 0.955 vs. 0.854; RVEF, 0.941 vs. 0.781 respectively, all p < 0.0001) with less bias and narrower limit of agreement (LOA). The bias and LOA for RV volumes and EF using the automated software without and with manual editing were greater in patients with severely impaired RV function or low frame rate than those with normal and mild impaired RV function, or high frame rate. The fully automated RV three-dimensional measurements were highly reproducible.Conclusion: The novel fully automated RV software shows good feasibility and reproducibility, and the measurements had a high correlation with CMR values. These findings support the routine application of the novel 3D automated RV software in clinical practice.

29 May 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Matiullah MasroorMatiullah Masroor
Matiullah Masroor
Ashfaq AhmadAshfaq Ahmad
Ashfaq Ahmad
YWYixuan Wang
Yixuan Wang
NDNianguo Dong
Nianguo Dong
Coronary artery bypass grafting (CABG) is the gold standard procedure for multi vessels and left main coronary artery disease. The prognosis and survival outcomes of CABG surgery are highly dependent on the patency of the bypass graft. Early graft failure which can occur during or soon after CABG remains a significant issue, with reported incidences of 3–10%. Graft failure can lead to refractory angina, myocardial ischemia, arrhythmias, low cardiac output, and fatal cardiac failure, emphasizing the importance of ensuring graft patency during and after surgery to prevent such complications. Technical errors during anastomosis are among the leading causes of early graft failure. To address this issue, various modalities and techniques have been developed to evaluate graft patency during and after CABG surgery. These modalities aim to assess the quality and integrity of the graft, thus enabling surgeons to identify and address any issues before they lead to significant complications. In this review article, we aim to discuss the strengths and limitations of all available techniques and modalities, with the goal to identify the best modality for evaluating graft patency during and after CABG surgery.

9 May 2024 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
Ashfaq AhmadAshfaq Ahmad
Ashfaq Ahmad
YZYifan Zou
Yifan Zou
PZPeng Zhang
Peng Zhang
LLLingling Li
Lingling Li
XWXiaoyu Wang
Xiaoyu Wang
FFFenling Fan
Fenling Fan
Pulmonary arterial hypertension (PAH) is a chronic and progressive disease that eventually leads to heart failure (HF) and subsequent fatality if left untreated. Right ventricular (RV) function has proven prognostic values in patients with a variety of heart diseases including PAH. PAH is predominantly a right heart disease; however, given the nature of the continuous circulatory system and the presence of shared septum and pericardial constraints, the interdependence of the right and left ventricles is a factor that requires consideration. Accurate and timely assessment of ventricular function is very important in the management of patients with PAH for disease outcomes and prognosis. Non-invasive modalities such as cardiac magnetic resonance (CMR) and echocardiography (two-dimensional and three-dimensional), and nuclear medicine, positron emission tomography (PET) play a crucial role in the assessment of ventricular function and disease prognosis. Each modality has its own strengths and limitations, hence this review article sheds light on (i) ventricular dysfunction in patients with PAH and RV–LV interdependence in such patients, (ii) the strengths and limitations of all available modalities and parameters for the early assessment of ventricular function, as well as their prognostic value, and (iii) lastly, the challenges faced and the potential future advancement in these modalities for accurate and early diagnosis of ventricular function in PAH.

31 October 2023 in Cardiology Discovery
Verified
Journal Article
Open access
Ashfaq AhmadAshfaq Ahmad
Ashfaq Ahmad
YZYifan Zou
Yifan Zou
PZPeng Zhang
Peng Zhang
LLLingling Li
Lingling Li
XWXiaoyu Wang
Xiaoyu Wang
FFFenling Fan
Fenling Fan
Right ventricular function is independently associated with poor clinical outcomes in patients with various cardiovascular diseases including pulmonary hypertension (PH). The complex geometry and mode of contractility means the right ventricle (RV) inlet and outlet are not in line; hence, 2-dimensional echocardiography fails to accurately quantify RV volumes and function in such patients. Three-dimensional echocardiography (3DE) allows for reliable and reproducible quantification of RV volumes and function by overcoming these limitations of conventional echocardiography. This review focuses on the 3DE assessment of RV function in patients with PH and discusses the following points: (1) acquiring an RV data set for 3DE imaging, including details of all available 3DE systems and software utilized in daily practice; (2) the reliability and feasibility of RV remodeling measured with 3DE with different modalities in patients with PH; and (3) the prognostic value of 3DE-derived RV function in such patients.

31 August 2023 in Journal of Back and Musculoskeletal Rehabilitation
Verified
Journal Article
Closed access
PDF file
MOMalik Abdulkadhim Oleiwi
Malik Abdulkadhim Oleiwi
SSSayed Zulfiqar Ali Shah
Sayed Zulfiqar Ali Shah
HBHazrat Bilal
Hazrat Bilal
AZAlam Zeb
Alam Zeb
Ashfaq AhmadAshfaq Ahmad
Ashfaq Ahmad
HCHong Chen
Hong Chen
BACKGROUND: Low back pain (LBP) is a prevalent disabling ailment that affects people all over the world. A wide variety of orthotic designs, ranging from lumbosacral corsets to rigid thermoplastic thoraco-lumbosacral orthosis are used for managing LBP. OBJECTIVE: Explore and summarize quality literature on the efficacy of orthotic devices in the management of LBP. METHODS: A systematic review and meta-analysis of the literature on the efficacy of orthosis in low back pain management conducted using electronic databases. Studies utilizing orthotic management alone or combined with other therapies for 2 weeks or above were included. A meta-analysis was performed on primary and secondary variables using Mean difference (MD), Inverse variance (IV), and fixed effect model with 95% CI, Physiotherapy Evidence Database (PEDro) scale, Cochrane Risk of Bias 2 (RoB2) tool were used to assess the quality of evidence and the risk bias. RESULTS: Out of 14671 studies, only 13 Randomized Controlled Trials (RCT) were deemed eligible for inclusion in this study, all level 1 evidence. We found that orthotics could significantly mitigate LBP (P-value < 0.00001). Similarly, a significant reeducation in LBP-associated disability was observed after orthotic intervention (P-value 0.004). CONCLUSION: Lumber orthosis plays a significant role in LBP and associated disability mitigations in sufferers of LBP.