Anton Soppelsa

Dr. Anton Soppelsa

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2008 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
ABA. Barbalace
A. Barbalace
ALA. Luchetta
A. Luchetta
GMG. Manduchi
G. Manduchi
MMM. Moro
M. Moro
ASAnton Soppelsa
Anton Soppelsa
CTC. Taliercio
C. Taliercio
We report on a set of performance measurements executed on VMEbus MVME5500 boards equipped with MPC7455 PowerPC processor, running four different operating systems: Wind River VxWorks, Linux, RTAI, and Xenomai. Some components of RTAI and Xenomai have been ported to the target architecture. Interrupt latency, rescheduling and inter-process communication times are compared in the framework of a sample real-time application. Performance measurements on Gigabit Ethernet network communication have also been carried out on the target boards. To this purpose, we have considered the Linux IP stack and RTnet, an open-source hard real-time network protocol stack for Xenomai and RTAI, which was ported to the considered architecture. Performance measurements show that the tested open-source software is suitable for hard real-time applications.

21 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
SBSimone Buffa
Simone Buffa
ASAnton Soppelsa
Anton Soppelsa
MPMauro Pipiciello
Mauro Pipiciello
GHGregor P Henze
Gregor P Henze
RFRoberto Fedrizzi
Roberto Fedrizzi
District heating and cooling (DHC) is considered one of the most sustainable technologies to meet the heating and cooling demands of buildings in urban areas. The fifth-generation district heating and cooling (5GDHC) concept, often referred to as ambient loops, is a novel solution emerging in Europe and has become a widely discussed topic in current energy system research. 5GDHC systems operate at a temperature close to the ground and include electrically driven heat pumps and associated thermal energy storage in a building-sited energy transfer station (ETS) to satisfy user comfort. This work presents new strategies for improving the operation of these energy transfer stations by means of a model predictive control (MPC) method based on recurrent artificial neural networks. The results show that, under simple time-of-use utility rates, the advanced controller outperforms a rule-based controller for smart charging of the domestic hot water (DHW) thermal energy storage under specific boundary conditions. By exploiting the available thermal energy storage capacity, the MPC controller is capable of shifting up to 14% of the electricity consumption of the ETS from on-peak to off-peak hours. Therefore, the advanced control implemented in 5GDHC networks promotes coupling between the thermal and the electric sector, producing flexibility on the electric grid.

20 August 2012 in Nuclear Fusion
Verified
Journal Article
Closed access
MBM. Baruzzo
M. Baruzzo
TBT. Bolzonella
T. Bolzonella
YLY.Q. Liu
Y.Q. Liu
GMG. Manduchi
G. Manduchi
GMG. Marchiori
G. Marchiori
FVF. Villone
F. Villone
In this paper, the results of resistive wall mode (RWM) control experiments using several sets of active coils are presented. The control effectiveness as a function of coil number and covered torus surface is studied in the RFX-mod device, thanks to the powerful and flexible MHD active control system. Active control is tried using similar coil number and size both in the reversed field pinch (RFP) and in the tokamak configurations, giving a good experimental set to exploit the differences between the two cases. The experimental results are compared with predictions by a new integrated simulator for closed loop RWM growth. The numerical tool couples, in a self-consistent way, a full 3D finite element description of the machine boundaries, a 2D toroidal model of RFP plasma stability and a model of the RFX-mod control system, producing an overall dynamic model cast in the state variable space. In this way a full dynamic flight simulator of RWM control experiments is implemented, where coil coverage and experimental proportional–integral–derivative gains are explored in simulations. Both in the performed experiments and in simulations wall mode active control is proven to be possible in both the configurations with a very reduced set of active control coils.

1 April 2008 in Fusion Engineering and Design
Verified
Journal Article
Closed access
FSF. Sartori
F. Sartori
FCF. Crisanti
F. Crisanti
RARaffaele Albanese
Raffaele Albanese
GAG. Ambrosino
G. Ambrosino
VTV. Toigo
V. Toigo
LZL. Zanotto
L. Zanotto

1 April 2007
Verified
Conference Paper
Closed access
ABA. Barbalace
A. Barbalace
ALA. Luchetta
A. Luchetta
GMG. Manduchi
G. Manduchi
MMM. Moro
M. Moro
ASAnton Soppelsa
Anton Soppelsa
CTC. Taliercio
C. Taliercio
We report on a set of performance measurements executed on VMEbus MVME5500 boards equipped with MPC7455 PowerPC processor, running four different operating systems: Wind River VxWorks, Linux, RTAI, and Xenomai. Some components of RTAI and Xenomai have been ported to the target architecture. Interrupt latency, rescheduling and inter-process communication times are compared in the framework of a sample real-time application. Performance measurements on Gigabit Ethernet network communication have also been carried out on the target boards. To this purpose, we have considered the Linux IP stack and RTnet, an open-source hard real-time network protocol stack for Xenomai and RTAI, which was ported to the considered architecture. Performance measurements show that the tested open-source software is suitable for hard real-time applications.

27 May 2011 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
LPL Piron
L Piron
JHJ M Hanson
J M Hanson
YIY In
Y In
GMG Marchiori
G Marchiori
LML Marrelli
L Marrelli
ESE J Strait
E J Strait