Atinuola Elizabeth Ayeoribe

Ms. Atinuola Elizabeth Ayeoribe

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2026 in Journal of Smart Computing and Quantum Technologies
Verified
Journal Article
Open access
PDF file
AAAtinuola Elizabeth Ayeoribe
Atinuola Elizabeth Ayeoribe
Olarewaju Peter AyeoribeOlarewaju Peter Ayeoribe
Olarewaju Peter Ayeoribe
Adaptive Learning Systems (ALS) have emerged as intelligent educational technologies for supporting personalized instruction, learner engagement, and educational equity; however, empirical evidence regarding their effectiveness across diverse classroom environments remains limited. This study evaluated the effectiveness of ALS in improving academic achievement, learner engagement, educational equity, and teacher-supported instructional adaptability. A mixed-methods research design incorporating a quasi-experimental pre-test–post-test control-group approach was employed with 720 students from six educational institutions across a 14-week intervention period. Quantitative data were obtained from curriculum-aligned pre-test and post-test assessments and system-generated learning analytics, while qualitative data were collected through classroom observations and teacher interviews. The experimental group recorded a mean learning gain of 28.6%, compared with 14.3% for the control group. Subject-specific improvements were highest in Mathematics (32.4%), followed by Science (29.1%), English Language (24.7%), and Social Studies (22.9%). Learners in the lowest achievement quartile recorded a 35.8% improvement, while the achievement gap between high- and low-performing learners decreased by 17.6%. Learning analytics indicated increased engagement, with average daily active engagement reaching 32.5 minutes and task completion reaching 87.3%. Teachers also reported improved instructional decision-making through real-time learner analytics. Overall, the findings indicate that ALS can support personalized, inclusive, and data-informed instruction while enhancing learner engagement and pedagogical adaptability across diverse classroom environments.

1 January 2025 in SSRN Electronic Journal
Verified
Preprint
Open access
Olarewaju Peter AyeoribeOlarewaju Peter Ayeoribe
Olarewaju Peter Ayeoribe
AAAtinuola Elizabeth Ayeoribe
Atinuola Elizabeth Ayeoribe
Cognitive fatigue impairs human performance in complex human–machine interaction (HMI) systems, leading to reduced efficiency and potential safety risks. This study presents a biomedical engineering approach for real-time monitoring of cognitive fatigue using electroencephalography (EEG) signals. EEG data were recorded from 30 participants performing sustained attention tasks in simulated HMI environments. Signals were preprocessed using band-pass filtering (0.5–45 Hz) and independent component analysis (ICA) for artifact removal. Fatigue-related features, including theta (4–7 Hz) and alpha (8–13 Hz) band power ratios were extracted. Using a support vector machine (SVM) classifier, cognitive fatigue was detected with an accuracy of 92%, sensitivity of 90%, and specificity of 94% in real-time monitoring. The results indicate a significant increase in theta/alpha ratios correlating with self-reported fatigue scores (Pearson’s r = 0.78, p < 0.01). This framework demonstrates the feasibility of EEG-based adaptive HMI systems for enhancing operator performance, safety, and overall well-being.

1 January 2025 in SSRN Electronic Journal
Verified
Preprint
Open access
Olarewaju Peter AyeoribeOlarewaju Peter Ayeoribe
Olarewaju Peter Ayeoribe
AAAtinuola Elizabeth Ayeoribe
Atinuola Elizabeth Ayeoribe

1 January 2025 in SSRN Electronic Journal
Verified
Preprint
Open access
Olarewaju Peter AyeoribeOlarewaju Peter Ayeoribe
Olarewaju Peter Ayeoribe
AAAtinuola Elizabeth Ayeoribe
Atinuola Elizabeth Ayeoribe
Electrodes are fundamental components in biomedical engineering, serving as the critical interface between biological tissue and electronic instrumentation. Their role is vital in acquiring, transmitting, and stimulating bioelectrical signals for diagnostic, monitoring, and therapeutic applications. This presentation explores the principles, types, and applications of biomedical electrodes, with a focus on their electrical properties, biocompatibility, and signal acquisition capabilities. Common categories such as surface electrodes, needle electrodes, and microelectrodes are examined, along with their respective uses in electrocardiography (ECG), electroencephalography (EEG), electromyography (EMG), neural recording, and deep brain stimulation. Special emphasis is placed on material considerations, including the use of silver/silver chloride, platinum, and conductive polymers, which enhance stability and reduce impedance at the electrode–tissue interface. Challenges such as motion artifacts, electrode polarization, and tissue reactions are also discussed, alongside recent innovations in flexible, wearable, and implantable electrodes. By bridging engineering design with physiological applications, this presentation highlights the essential role of electrodes in advancing biomedical technologies for improved healthcare diagnostics, monitoring, and therapy. Introduction In biomedical engineering, electrodes are indispensable tools that enable the measurement and modulation of bioelectric signals. Since the body generates electrical activity in tissues such as the brain, heart, and muscles, electrodes serve as the interface that allows these signals to be detected, amplified, and analysed using biomedical instruments. Beyond diagnostics, electrodes are also applied in therapeutic interventions such as neural stimulation, cardiac pacing, and functional electrical stimulation. The study of electrodes encompasses not only their classification but also the science of electrode–tissue interactions, material properties, and signal fidelity. Advances in electrode technology have enabled breakthroughs in non-invasive monitoring, implantable devices, and neuroengineering applications. With the emergence of flexible, nanostructured, and biocompatible materials, the role of electrodes in biomedical innovation continues to expand, making them central to the future of healthcare technology. Objectives The objectives of this presentation are: 1. To explain the fundamental principles and functions of biomedical electrodes. 2. To classify the different types of electrodes (surface, needle, and microelectrodes) and their specific applications. 3. To describe the material properties and design considerations that influence electrode performance. 4. To examine common challenges such as impedance, motion artifacts, and tissue reactions. 5. To highlight emerging trends in electrode technology, including flexible, wearable, and implantable systems. 6. To demonstrate the relevance of electrodes in diagnostics, monitoring, and therapeutic biomedical devices. Conclusion Electrodes remain a cornerstone of biomedical engineering, bridging the gap between biological systems and medical technology. They enable the detection of vital physiological signals, support diagnostic procedures, and provide therapeutic interventions in critical healthcare applications. Although traditional electrodes such as silver/silver chloride remain widely used, ongoing research in advanced biomaterials and flexible electronics is paving the way for next-generation biomedical electrodes that are more biocompatible, reliable, and adaptable. By addressing challenges such as noise, polarization, and tissue compatibility, biomedical engineers can continue to improve electrode performance. Ultimately, the development of innovative electrode technologies is essential for advancing diagnostics, patient monitoring, and therapeutic strategies in modern medicine.

12 November 2025 in Research Square
Verified
Preprint
Open access
PDF file
Olarewaju Peter AyeoribeOlarewaju Peter Ayeoribe
Olarewaju Peter Ayeoribe
AAAtinuola Elizabeth Ayeoribe
Atinuola Elizabeth Ayeoribe
Cognitive fatigue significantly impairs human performance in safety-critical Human–Machine Interaction (HMI) environments such as driving, aviation, and industrial control. Traditional detection methods based on behavioral or self-report measures are subjective and non-continuous. This study presents a real-time Electroencephalography (EEG)-based cognitive fatigue detection system integrating biomedical signal processing and deep learning for accurate and rapid assessment of mental fatigue. EEG data were acquired from a 14-channel headset and preprocessed using bandpass and notch filters, followed by Independent Component Analysis for artifact removal. Time–frequency features such as Power Spectral Density (PSD), Hjorth parameters, and the (Theta + Alpha)/Beta ratio were extracted and classified using a hybrid Convolutional–Long Short-Term Memory (CNN–LSTM) model. The system achieved a classification accuracy of 94.2%, outperforming traditional models such as SVM and Random Forest. Real-time implementation on an embedded platform achieved a processing latency of < 500 ms, confirming operational feasibility. The results demonstrate the potential of biomedical EEG monitoring for continuous cognitive state assessment and adaptive automation in high-demand environments.

18 September 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
OAOlarewaju Peter Ayeoribe
Olarewaju Peter Ayeoribe
OBOmodunbi B.A
Omodunbi B.A
OAOlaitan Akinsanmi
Olaitan Akinsanmi
AEAdebimpe Esan
Adebimpe Esan
AAAtinuola Elizabeth Ayeoribe
Atinuola Elizabeth Ayeoribe
Communication engineering relies fundamentally on modulation, frequency conversion, multiplexing, and broadcast transmission principles for the efficient delivery of information through wireless communication channels. The article, ICE 311: Communication Engineering Principles I presents a structured scholarly educational resource designed to develop students' theoretical understanding and practical interpretation of fundamental analogue communication and broadcasting systems. The material systematically examines the purpose and principles of modulation, classifications of modulation techniques, and the engineering considerations governing their selection for specific communication applications. Amplitude modulation (AM) systems are treated through comparative analysis of conventional AM, doublesideband, and single-sideband techniques, including signal generation and detection, frequency mixing and multiplication, frequency-division multiplexing, and practical broadcasting applications. Frequency modulation (FM) is examined through instantaneous frequency, frequency deviation, modulation index, Bessel-function coefficients, significantsideband criteria, transmission bandwidth, signal power, narrowband FM, and direct and indirect generation techniques. The educational material further addresses FM demodulation using discriminators, ratio detectors, and phase-locked loops, together with limiting, automatic frequency control, squelch circuits, pre-emphasis, de-emphasis, and stereophonic broadcasting. AM and FM broadcast-band specifications, image-frequency formation, and receiver architectures are also examined. Television broadcasting principles are extended from signal formats to transmitter and receiver block diagrams for black-and-white and colour television systems. Mathematical formulations, system-level explanations, and engineering block representations are integrated to strengthen conceptual understanding and support analytical interpretation. The material ultimately enables learners to compare modulation systems, identify their operational limitations, interpret broadcast specifications, and select appropriate modulation techniques for diverse communication and broadcasting scenarios.