Maria Atlaskina

Mrs. Maria Atlaskina

Laboratory of Membrane and Catalytic Processes, Nizhny Novgorod State Technical University n.a. R.E. Ale-kseev, 24 Minin str., Nizhny Novgorod, 603950, Russian Federation
+1
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2021 in Environments
Verified
Journal Article
Open access
PDF file
MAMaria Atlaskina
Maria Atlaskina
Artem AtlaskinArtem Atlaskin
Artem Atlaskin
OKOlga V. Kazarina
Olga V. Kazarina
Anton PetukhovAnton Petukhov
Anton Petukhov
DZDmitriy Zarubin
Dmitriy Zarubin
IVIlya V. Vorotyntsev
Ilya V. Vorotyntsev
The present study provides a solvent-free organic synthesis of quaternary ammonium salts: bis(2-hydroxyethyl)dimethylammonium taurate ([BHEDMA][Tau]) and bis(2-hydroxyethyl)dimethylammonium acetate ([BHEDMA][OAc]). These ionic compounds are promising materials for carbon dioxide capture processes, as mono sorbents, supplemental components in the conventional process of chemical absorption, and in the combined membrane approach for improving sorption efficiency. The synthesized compounds were characterized by 1H NMR and FT-IR spectroscopies and elemental analysis. Afterward, the sorption properties of the compounds were evaluated using the inverse gas chromatography (IGC) method, and their thermodynamic parameters were calculated in the temperature range of 303.15–333.15 K. The enthalpy change (∆sH) was less than 80 kJ·mol−1, indicated by the physical nature of sorption and also proved by FT-IR. Henry’s law constant in regard to carbon dioxide at 303.15 K was equal to 4.76 MPa for [BHEDMA][Tau], being almost 2.5 lower than for [BHEDMA][OAc] (11.55 MPa). The calculated carbon dioxide sorption capacity for [BHEDMA][Tau] and [BHEDMA][OAc] amounted to 0.58 and 0.30 mmol·g−1, respectively. The obtained parameters are comparable with the known solid sorbents and ionic liquids used for CO2 capture. However, the synthesized compounds, combining the advantages of both alkanolamines and ionic liquids, contain no fluorine in their structure and thus match the principles of environmental care.

5 December 2023 in Journal of Molecular Liquids
Verified
Journal Article
Closed access
MAMaria Atlaskina
Maria Atlaskina
OKOlga V. Kazarina
Olga V. Kazarina
APAnton N. Petukhov
Anton N. Petukhov
AAArtem A. Atlaskin
Artem A. Atlaskin
NTNikita S. Tsivkovsky
Nikita S. Tsivkovsky
IVIlya V. Vorotyntsev
Ilya V. Vorotyntsev

10 February 2024 in Chemical Engineering Journal Advances
Verified
Journal Article
Open access
Anton PetukhovAnton Petukhov
Anton Petukhov
AAArtem A. Atlaskin
Artem A. Atlaskin
MKMaria Kudryavtseva
Maria Kudryavtseva
DSDmitry N. Shablykin
Dmitry N. Shablykin
ESEkaterina A. Stepanova
Ekaterina A. Stepanova
IVIlya V. Vorotynstev
Ilya V. Vorotynstev

30 May 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Anton PetukhovAnton Petukhov
Anton Petukhov
AAArtem A. Atlaskin
Artem A. Atlaskin
KSKirill A. Smorodin
Kirill A. Smorodin
SKSergey Sergeevich Kryuchkov
Sergey Sergeevich Kryuchkov
DZDmitriy Zarubin
Dmitriy Zarubin
IVIlya V. Vorotyntsev
Ilya V. Vorotyntsev
The present study continues the development and enhancement of a highly efficient unique hybrid technique—membrane-assisted gas absorption in designing the separation unit, which provides the improvement in mass-transfer of a target component during the ammonia capture process from a process loop of the Haber–Bosch technological route. In order to minimize the absorbent volume to membrane area ratio, the special separation cell was designed based on a combination of two types of hollow fiber membranes, dense gas separation membrane and porous pervaporation membrane. The separation performance tests were implemented under two sets of conditions, sweeping the bore (permeate) side of a cell with helium and hydrogen-nitrogen mix. For both cases, the membrane-assisted gas absorption cell demonstrated high separation efficiency, and the ammonia concentration in the permeate was never lower than 81 mol%; meanwhile, under the hydrogen-nitrogen bore sweep conditions, the ammonia concentration in the permeate reached 97.5 mol% in a single-step process. Nevertheless, there is a product purity–recovery rate trade-off, which is a typical issue for separation processes.

1 July 2019 in Journal of Catalysis
Verified
Journal Article
Closed access
AVAndrey V. Vorotyntsev
Andrey V. Vorotyntsev
Anton PetukhovAnton Petukhov
Anton Petukhov
Tatyana SazanovaTatyana Sazanova
Tatyana Sazanova
VPVictoria Pryakhina
Victoria Pryakhina
ANAlexander V. Nyuchev
Alexander V. Nyuchev
VVVladimir M. Vorotyntsev
Vladimir M. Vorotyntsev

24 February 2023 in Membranes
Verified
Journal Article
Open access
PDF file
AAArtem A. Atlaskin
Artem A. Atlaskin
Anton PetukhovAnton Petukhov
Anton Petukhov
ASAnna N. Stepakova
Anna N. Stepakova
NTNikita Sergeevich Tsivkovsky
Nikita Sergeevich Tsivkovsky
SKSergey Sergeevich Kryuchkov
Sergey Sergeevich Kryuchkov
IVIlya V. Vorotyntsev
Ilya V. Vorotyntsev
The present paper deals with the complex study of CO2 capture from combined heat power plant flue gases using the efficient technological design of a membrane cascade type of «Continuous Membrane Column» for binary gas mixture separation. In contrast to well-known multi-step or multi-stage process designs, the cascade type of separation unit provides several advantages. Here, the separation process is implemented in it by creating two counter current flows. In one of them is depleted by the high-permeable component in a continuous mode, meanwhile the other one is enriched. Taking into account that the circulating flows rate overcomes the withdrawn one, there is a multiplicative increase in separation efficiency. A comprehensive study of CO2 capture using the membrane cascade type of «Continuous Membrane Column» includes the determination of the optimal membrane material characteristics, the sensitivity study of the process, and a feasibility evaluation. It was clearly demonstrated that the proposed process achieves efficient CO2 capture, which meets the modern requirements in terms of the CO2 content (≥95 mol.%), recovery rate (≥90%), and residual CO2 concentration (≤2 mol.%). Moreover, it was observed that it is possible to process CO2 with a purity of up to 99.8 mol.% at the same recovery rate. This enables the use of this specific process design in CO2 pretreatment operations for the production of high-purity carbon dioxide.