15 February 2005 in Optics Letters
Phase retrieval is the key to quantitative x-ray phase-contrast imaging. To retrieve the phase image of an x-ray wave field, in general one needs multiple phase-contrast images. We have made a new observation of phase-attenuation duality for soft tissues, and we show how only a single phase-contrast image is needed for successful phase retrieval based on this duality. The phase-retrieval formula based on a single phase-contrast image of inhomogeneous soft tissue is derived and presented. We show the striking enhancement of the tissue contrast in simulated phase images that this new approach produces.
24 July 2003 in Medical Physics
29 January 2007 in Medical Physics
13 August 2004 in Medical Physics
22 June 2009 in Optics Express
Phase retrieval is required for achieving artifact-free x-ray phase-sensitive 3D imaging. A phase-retrieval approach based on the phase-attenuation duality with high energy x-rays can greatly facilitate for phase sensitive imaging by allowing phase retrieval from only one single projection image. The previously derived phase retrieval formula is valid only for small Fresnel propagator phases corresponding to common clinical imaging tasks. In this work we presented a new duality-based phase retrieval formula that can be applied for cases with large Fresnel propagator phases corresponding to high spatial resolution imaging. The computer simulation demonstrated superiority of this new formula over the previous phase retrieval formula in reconstructing the high frequency components of imaged objects. A modified Tikhonov regularization technique has been devised for phase retrieval in cases of very high resolution and large object-detector distance such that some Fresnel propagator phases may be close or greater than π. This new phase retrieval formula lays the foundation for implementing high-resolution phase-sensitive 3D imaging of soft tissue objects.
1 October 2005 in Applied Optics
Phase-space formulation based on the Wigner distribution has been presented for analyzing phase-contrast image formation. Based on the statistical nature and affine canonical covariance of Wigner distributions in the phase space, we show that the partial coherence effects of incident x-ray wave field on image intensity are simply accounted for by a multiplication factor, which is the reduced complex degree of coherence of the incident x-ray wave field. We show especially that with the undulator sources one cannot obtain the phase-contrast intensity by summing over the contributions from all electron positions, since the van Cittert–Zernike theorem fails in general for undulators. We derive a comprehensive formula that quantifies the effects of partial spatial coherence, polychromatic spectrum, body attenuation, imaging-detector resolution, and radiation dose on phase-contrast visibility in clinical imaging. The results of our computer modeling and simulations show how the formula can provide design guidelines and optimal parameters for clinical x-ray phase-contrast imaging systems.