13 April 2023 in Measurement
3 March 2025 in IEEE Sensors Journal
This paper proposes an intensity-modulated liquid level sensor based on cascaded long-period fiber grating (LPFG) and fiber Bragg grating (FBG) structure with temperature compensation. Its unique structure converts the wavelength shift of the LPFG transmission peak caused by the liquid level change into a variable in the intensity of the FBG reflection peak. By inducing the combined action of LPFG and FBG, a new coupling peak is generated in the reflection spectrum for temperature compensation, reducing the interference of environmental temperature on liquid level measurement. A rigorous theoretical model was established, simulations were conducted, and experiments were performed to verify the results. In the experiment, the intensity variation of the FBG peak and the wavelength variation of the LPFG-FBG interaction peak in the reflection spectrum were used to measure the two parameters. The results show that when the liquid level changes within 15 mm, the intensity sensitivity of the corresponding FBG peak is -0.488 dB/mm. The wavelength of the LPFG-FBG interaction peak remains essentially unchanged. Within the temperature range of 30-60 °C, the intensity sensitivity of the corresponding FBG peak is 0.0374 dB/°C, and the wavelength sensitivity of the LPFG-FBG interaction peak is 8.78 pm/°C. Using a 2×2 matrix, simultaneous measurement of liquid level and temperature can be achieved, realizing temperature compensation. This sensor features high sensitivity, simple structure, high linearity, and low detection cost, promising a good application prospect in the field of liquid level sensing.
14 May 2025 in IEEE Sensors Journal
In the paper, a temperature and relative humidity (RH) sensor based on a half-covered agarose fiber Bragg grating (HC-AFBG) is proposed and experimentally validated. A single fiber Bragg grating (FBG) is utilized as the sensing core for the sensor, with half the length of the FBG coated with humidity-sensitive agarose (AG) material. Utilizing the ability of AG to stretch or shrink with changes in humidity, the grating period of the FBG can be altered, which in turn creates new reflection peaks in the reflection spectrum. We experimented and verified the behavior of the two reflection peaks of HC-AFBG at different humidity and temperature and solved the cross-sensitivity problem. The experimental results show that the humidity sensitivity is 73.0 pm/%RH in the range of 35 %RH 65 %RH. And the temperature sensitivities of the two peaks are 13.3 pm/°C and 9.6 pm/°C in the range of 25 60 °C. Using the obtained temperature and humidity sensitivity to construct a sensitivity measurement matrix, humidity and temperature can be monitored simultaneously. This study presents a HC-AFBG sensor capable of high-sensitivity, simultaneous temperature and humidity sensing, offering a promising tool for various environmental monitoring applications.
3 June 2026 in IEEE Transactions on Instrumentation and Measurement
This study presents a smart insole sensing system that integrates surface array fiber Bragg grating (FBG) technology with deep learning algorithms and is specifically designed to monitor gait posture. The system architecture integrates three interconnected modules: the insole sensing module, the signal reception module, and the signal processing module. By synergizing high-precision fiber-optic sensing with artificial intelligence to achieve real-time, non-invasive, and detailed tracking of human gait characteristics. The key to this system lies in strategically installing 8-channel surface-array FBG sensors at the first metatarsophalangeal joint and the calcaneal tuberosity, ensuring coverage of the high-pressure area. Coupled with a neural network-based data processing pipeline, the system demonstrates an accuracy of 98.99% in classifying normal human gait postures, and its high-precision plantar pressure mapping capability endows it with potential for pathological pressure distribution detection in clinical gait monitoring. Comparative evaluations reveal superior linearity, stability, and anti-interference capability compared to conventional sensors. Through experimental verification, including dynamic posture transformation tests and long-term repetitive tests, the reliability of the system has been confirmed. This work establishes a scalable framework for optical-sensor-integrated wearable healthcare solutions, with potential applications in diabetic foot ulcer prevention, stroke rehabilitation, and sports performance optimization.
24 November 2025 in IEEE Sensors Journal
In the paper, a novel, all-fiber acoustic sensor utilizing a Fabry-Perot interferometer is proposed, which is composed of a single mode fiber (SMF) integrated with a gold and polydimethylsiloxane (PDMS) composite film. The SMF is inserted into a homemade, 3D-printed ceramic sleeve, and the cavity length can be adjusted nimbly by controlling the distance from the SMF to the gold film. Considering the significant correlation between sensitivity and film thickness in theory, an investigation is conducted into the influence of varying PDMS thicknesses on the acoustic pressure sensitivity of the sensor experimentally. Through the precise regulation of the rotational speed, four PDMS thin films with varying thicknesses are fabricated by a commercial gluing machine. The experimental results indicate that the maximum acoustic pressure sensitivity can reach 1.341 V/Pa. Moreover, our sensor exhibits a flat frequency response range spanning from 1 kHz to 16 kHz, with the highest signal to noise ratio attaining 75 dB at 14 kHz. The noise-limited minimum detectable pressure level of 12.14 μPa/Hz1/2@14 kHz can be achieved in air, and the applied sound pressure is 68.55 mPa. Owing to its simplicity, low cost, and high signal to noise ratio, this sensor is a promising choice in the field of sound detection.
1 October 2026 in IEEE Sensors Journal