20 September 2011 in Indoor and Built Environment
In this research, several models were developed to forecast the daily mean indoor temperature (IT) and relative humidity values in an education building in Izmir, Turkey. The city is located at a hot–humid climatic region. In order to forecast the IT and internal relative humidity (IRH) parameters in the building, a number of artificial neural networks (ANN) models were trained and tested with a dataset including outdoor climatic conditions, day of year and indoor thermal comfort parameters. The indoor thermal comfort parameters, namely, IT and IRH values between 6 June and 21 September 2009 were collected via HOBO data logger. Fraction of variance ( R2) and root-mean squared error values calculated by the use of the outputs of different ANN architectures were compared. Moreover, several multiple regression models were developed to question their performance in comparison with those of ANNs. The results showed that an ANN model trained with inconsiderable amount of data was successful in the prediction of IT and IRH parameters in education buildings. It should be emphasized that this model can be benefited in the prediction of indoor thermal comfort conditions, energy requirements, and heating, ventilating and air conditioning system size.
1 September 2021 in Gazi University Journal of Science
Today, increasing energy costs and environmental problems make it mandatory to use energy efficiently in buildings. Universities with high energy consumption have become the focus to save energy in the building sector. At the same time, universities with many buildings and infrastructures are like small settlements. Major objective of this study is to compare historical energy consumption of different types of buildings over a ten-year period. Thus, it shows an overall picture of energy consumption in Çağış Campus of Balikesir University. It has been observed that the university hospital is a very large energy consumer compared to other buildings. In addition to this building, the energy consumed in four buildings such as Faculty of Engineering and Architecture, Rectorate, Medico Social Building and Faculty of Science and Letters corresponds to 70% of the total energy used in Çağış Campus between 2008-2019. The results obtained from the study will be beneficial for universities' related staff to manage energy use and to determine the priorities for retrofitting.
4 June 2020 in Proceedings of the Institution of Civil Engineers - Engineering Sustainability
Due to the large number of buildings, energy consumption in the university campuses of Turkey may tend to increase over time. In this context, their potential energy savings need to be explored. Therefore, the aim of this paper is to investigate energy savings in university campuses by applying different energy-efficient measures with simulation-based analysis. To do that, four buildings from the Balıkesir University campus were the focus of the present study. The energy billing data were used to calibrate and adjust the simulation models produced from the DesignBuilder software. The results showed that an energy reduction of over 60% in the examined buildings is possible with proper energy-efficient solutions, which is considered very effective. This means that the findings demonstrate a high potential for campus building retrofitting with passive, active and combined strategies. The energy-saving potentials calculated for each building can guide university authorities to determine feasible energy-saving techniques for buildings with large energy conservation potential and forecast future retrofitting planning development in campuses.
1 November 2019 in Proceedings of the Institution of Civil Engineers - Energy
Analysing learning environments is important because classrooms can affect students’ well-being and learning performance. In this paper, a field study was conducted based on a mixed method for a better understanding of indoor environmental conditions in six buildings of Balikesir University in Turkey. The perceptions of students were combined with measurements and surveys. The environmental parameters such as indoor and outdoor air temperature, indoor black globe temperature, indoor and outdoor relative humidity, indoor carbon dioxide concentration and air velocity were measured. A total of 1782 responses from students were also obtained. The recorded values of mean indoor air temperature, relative humidity, black globe temperature and air velocity were 23·4°C, 39·8%, 22·9°C and 0·09 m/s, respectively. Carbon dioxide concentrations usually exceeded the threshold of 1000 ppm. Over 55% of students said they found indoor conditions thermally acceptable in all classrooms during the field study. The mean neutral temperatures, as predicted by actual and predicted mean values, were 21·7 and 23·1°C. Indoor measured temperatures were mostly found to be higher than neutral temperatures. The findings can be used for the design and evaluation of indoor conditions and heating systems in university buildings.
31 August 2008 in Journal of Shoulder and Elbow Surgery
25 September 2019 in METU Journal of the Faculty of the Architecture