Soon-Man Kwon

Soon-Man Kwon

Auto-generated profile, based on publicly available information

Soon-Man Kwon

Korea Electrotechnology Research Institute, 87785 Changwon, Gyeongsangnam-do Korea (the Republic of)

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
PLPhuong Thi Luu
Phuong Thi Luu
JLJi-young Lee
Ji-young Lee
Ji-Won KimJi-Won Kim
Ji-Won Kim
SCShi-Uk Chung
Shi-Uk Chung
SKSoon-Man Kwon
Soon-Man Kwon
This study focuses on the design of a magnetic sensor (MS) in position detection of a permanent magnet linear motor (PMLM). The MS is composed of a Hall-IC and magnetic materials, and it is well-known as a contactless sensor with a simple structure, and low cost. As a result, it is preferred for precise linear positioning applications. The work presented in this study consists of the following three steps to achieve high accuracy and economy in the mover position detection for a PMLM. Firstly, the initial design of the MS is described which has been optimized using response surface methodology to obtain very low total harmonic distortion value of the sensing signal. Secondly, the leakage flux of PMLM is analytically investigated, from which it is determined that shielding the leakage flux is most appropriate to ensure the accuracy of the MS. Finally, in an attempt to reduce manufacturing cost, three MS prototypes using different materials (silicon steel laminated core, steel solid core, and ferrite solid core) are fabricated and tested. To verify the analytical results, several experiments were conducted. The experimental data proves that the accuracy of the MS is sufficient to use for mover position detection for the PMLM.

1 July 2006
Verified
Conference Paper
Closed access
SKSoonman Kwon
Soonman Kwon
JCJong-Min Cheon
Jong-Min Cheon
JLJongmoo Lee
Jongmoo Lee
CKChoon-Kyung Kim
Choon-Kyung Kim
SKSeog-Joo Kim
Seog-Joo Kim
The design and implementation of a fault-tolerant control rod control system for nuclear power plants is described. High reliability and safety are necessary for the instrumentation and control systems for safety-critical plants such as nuclear power plants. For a control rod control system that controls the nuclear reactivity inside the reactor by inserting or withdrawing the rods into or from the reactor, the reliability is more critical than the safety since its malfunction directly results in an unexpected shutdown of the power plant. This paper deals with a design and implementation practice to enhance the reliability of the control system. The reliability enhancement is basically achieved by adopting hardware redundancy in its structure. The reliability is evaluated quantitatively to check if the designed and implemented system is reliable enough to be applied to commercial plants. The ability of fault detection realized in the system is expected to give a further reliability enhancement by means of software. The bumpless control problem that can be arisen from adopting hardware redundancy is discussed here. Also a new algorithm for the rod movement detection is briefly introduced and demonstrated with a test result