Anne-Sofie Madsen Staples

Anne-Sofie Madsen Staples

Auto-generated profile, based on publicly available information

Anne-Sofie Madsen Staples

Department of Biomedical Sciences, University of Copenhagen, Copenhagen, Denmark

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Therapeutics and Clinical Risk Management
Verified
Journal Article
Open access
PDF file
JPJesper Park-Hansen
Jesper Park-Hansen
AGAnders M Greve
Anders M Greve
JCJohan Sr Clausen
Johan Sr Clausen
SHSusanne Jv Holme
Susanne Jv Holme
CCChristian Lildal Carranza
Christian Lildal Carranza
HDHelena Dominguez
Helena Dominguez

Background:
Incident atrial fibrillation (AF) is reported in 10%–65% of patients without previous AF diagnosis after open heart surgery. The risk of late AF recurrence after a postoperative AF onset is unclear, and it is controversial whether AF limited to the postoperative period should elicit oral anticoagulation (OAC) therapy. The primary objective of this study was to evaluate the long-term recurrence of AF in patients developing new-onset peri-procedural AF. Patients and methods: Patients (n=189) with available baseline and follow-up data included in Left Atrial Appendage Closure with Surgery trial were coded for known AF at baseline and for postoperative first-time AF diagnosis. AF occurrence was classified as follows: peri-procedural ≤7 days postoperatively, early >7 days but ≤3 months and late >3 months. Patients with no AF recurrence registered during follow-up were invited to undergo Holter monitoring. Results: A total of 163 (86.2%) patients had no history of AF. Among these, 80 (49.1%) developed new-onset peri-procedural AF. After a mean follow-up of 3.7±1.6 years, late AF occurred in 35 of the 80 (43.8%) patients who developed peri-procedural AF and in 6 additional patients (7.2%) who remained in sinus rhythm until discharge (hazard ratio [HR] 9.3, 95% CI 3.8–22.4, p<0.001). Patients with peri-procedural AF and early AF had 12.24 times higher risk of late AF (95% CI 4.76–31.45, p<0.001) as compared to the group with no postoperative AF. Conclusion: New-onset of AF after open heart surgery has a high rate of recurrence and should not be regarded as a self-limiting phenomenon secondary to surgery.

22 February 2024 in Journal of Diabetes Science and Technology
Verified
Journal Article
Closed access
ASAnne-Sofie Madsen Staples
Anne-Sofie Madsen Staples
MPMette Poulsen
Mette Poulsen
KPKezia Ann Friis Præstmark
Kezia Ann Friis Præstmark
TSThomas Sparre
Thomas Sparre
MTMarie Sand Traberg
Marie Sand Traberg
Background: This study examines how shield-triggered autoinjectors (AIs), for subcutaneous drug delivery, affect injection depth. It focuses on shield size and applied force, parameters that could potentially lead to inadvertent intramuscular (IM) injections due to tissue compression. Method: A blinded ex-vivo study was performed to assess the impact of shield size and applied force on injection depth. Shields of 15, 20, and 30 mm diameters and forces from 2 to 10 N were investigated. The study involved 55 injections in three Landrace, Yorkshire, and Duroc (LYD) pigs, with injection depths measured with computed tomography (CT). An in-vivo study, involving 20 injections in three LYD pigs, controlled the findings, using fluoroscopy (FS) videos for depth measurement. Results: The CT study revealed that smaller shield sizes significantly increased injection depth. With a 15 mm diameter shield, 10 N applied force, and 5 mm needle protrusion, the injection depth exceeded the needle length by over 3 mm. Injection depth increased with higher applied forces until a plateau was reached around 8 N. Both applied force and size were significant factors for injection depth (analysis of variance [ANOVA], P < .05) in the CT study. The FS study confirmed the ex-vivo findings in an in-vivo setting. Conclusions: The study demonstrates that shield size has a greater impact on injection depth than the applied force. While conducted in porcine tissue, the study provides useful insights into the relative effects of shield size and applied force. Further investigations in humans are needed to confirm the predicted injection depths for AIs.

9 August 2023 in Journal of Diabetes Science and Technology
Verified
Journal Article
Closed access
ASAnne-Sofie Madsen Staples
Anne-Sofie Madsen Staples
JSJulie Schwartz
Julie Schwartz
KPKezia Ann Friis Præstmark
Kezia Ann Friis Præstmark
MTMarie Sand Traberg
Marie Sand Traberg
Background: Pen needles and autoinjectors are necessary for millions of patients needing injectable drug treatment but pose economic and environmental burdens. A durable device with a multiuse needle could reduce cost and improve user experience. This study explores a novel robust needle tip (EXP) designed for multiple uses and durability against hooking. Method: Needle robustness was investigated through a structural analysis. Furthermore, EXP and control needles (NF30, NF28) were evaluated in an in-vivo porcine model as pen needles or embedded in autoinjectors to study the resulting increase in skin blood perfusion (SBP). The SBP was assessed by laser speckle contrast analysis (LASCA) of 192 randomized and blinded needle insertions. Results: Forming a 33 µm hook against a hard surface requires 0.92 N for the NF30 control needle and 5.38 N for EXP. The EXP did not induce more tissue trauma than the NF30. There was a positive relation between needle diameter and SBP ( P < .05). Furthermore, the presence of an autoinjector shield and applied force of 10 N was found to significantly reduce SBP for worn EXP needles ( P < .05) compared to insertions without autoinjector shield. Conclusions: The investigated robust needle EXP is on par with the single-use needle NF30 in terms of tissue trauma, which is further reduced by combining the needle with a needle shield. These results should encourage the innovation and development of durable, reusable injection systems with pharmacoeconomic and environmental value and a simplified and enhanced user experience for patients.

2 September 2025 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
ASAnne-Sofie Madsen Staples
Anne-Sofie Madsen Staples
AMAdam Bo Mandel
Adam Bo Mandel
LALeyre Azcarate
Leyre Azcarate
MTMarie Sand Traberg
Marie Sand Traberg

2 October 2024 in Expert Opinion on Drug Delivery
Verified
Journal Article
Closed access
ASAnne-Sofie Madsen Staples
Anne-Sofie Madsen Staples
HAHanaa Abuo-Chalih
Hanaa Abuo-Chalih
DSDan Nørtoft Sørensen
Dan Nørtoft Sørensen
ObjectiveThis noninvasive study aimed to understand the interaction between shield-triggered autoinjectors (AI) and skin at the point of activation, hypothesizing that the AI's housing absorbs a significant amount of the user-applied force depending on shield design and skin characteristics. MethodsTwenty-seven volunteers used a test device measuring applied force versus shield force and indentation depth relative to shield length (2,4,6,8 mm) in standing and sitting positions. ResultsSignificant differences were found between applied and shield force for the different shield lengths. Shorter shields resulted in significantly lower force transfer coefficients, with means ranging from 0.72 for the 2 mm shield to 0.94 for the 8 mm shield. ANOVA revealed statistically significant factors (p < .05), including position and gender, with females generally having lower coefficient values. Indentation depth increased with higher forces and varied significantly between positions without significant shield length impact. ConclusionThe findings confirm that an increase in shield length at the point of activation reduces skin friction with the housing, resulting in less force loss and a lower device activation force perceived by the user. Force loss can be further reduced by standing up. Understanding device-tissue interactions will support development of better AIs with fewer user failures.