24 September 2023 in Reliability Engineering & System Safety
25 June 2023 in Measurement
21 July 2023 in IEEE Sensors Journal
Natural gas pipelines are an important mode of transportation. How to quickly and accurately detect abnormal signals that occur during pipeline operation is crucial to judging the pipeline status. In this paper, an abnormal signal detection method based on improved YOLOv7 (YOLO-PD) was proposed to address the low detection accuracy of abnormal signals and the dependence on manual signal segmentation scale setting in pipeline operation. Firstly, a new refined channel attention (RCA) module was proposed to enhance network feature extraction. Secondly, a MaxPooling with RCA module was designed to strengthen network feature extraction and fusion capabilities. Furthermore, the atrous spatial pyramid pooling with RCA module was used to expand the model’s receptive field and enhance the core information features, thereby improving the detection accuracy of the model for multi-scale objects. Subsequently, the SIoU loss function was utilized to expedite network convergence and optimize the model training process. The experimental results demonstrate that YOLO-PD exhibits high accuracy and speed, with an mAP@0.5 of 0.996 and a frame rate of 65. In comparison to other prevalent target detection algorithms, the method proposed in this paper can effectively identify abnormal signals in pipelines and achieve higher detection accuracy.
2 October 2023 in IEEE Sensors Journal
We propose a flexible wearable respiratory sensor based on microspheres coupling, where the sensing element is a microfiber embedded in a polydimethylsiloxane (PDMS) film doped with 5μm diameter silica microspheres. In this study, PDMS doped with microspheres were used to coat microfibers for the first time, and the enhancement of the evanescent field on the surface of microfibers was observed. Theoretically and experimentally, it is found that the light transmitted in the optical fiber core is effectively dragged by the microsphere, which significantly enhances the evanescent field and thus improves the sensitivity of the sensing element. During the respiratory monitoring, the pressure generated by the respiratory airflow causes the sensing element to bend, and the self-mixing interference is used to detect the power change of reflected light to reconstruct the respiratory signal. The empirical findings demonstrate a peak in sensor sensitivity at a microsphere doping concentration of 0.1 g/mL while a subsequent augmentation in microspheres doping concentration inversely correlates with sensor sensitivity. Notably, the sensor developed with a 0.1 g/mL microspheres doping concentration exhibits an exceptional capacity for continuous, real-time differentiation among diverse respiratory signals. This innovation is characterized by its elevated sensitivity and responsiveness, evidenced by an impressively short 28 ms response time. To validate the sensor’s effectiveness, we employed the Bland-Altman statistical analysis test to assess the accuracy of respiration rate measurements using the collected data from the test subjects. The favorable outcomes we obtained offer a promising avenue for advancing research in the realm of non-invasive vital signs monitoring.
16 April 2024 in IEEE Sensors Journal
This study presents a novel sensor that combines air pressure and temperature measurement using dual-interference microfiber resonators. The sensor leverages intermode interference and the resonant ring resonance effects within the microfiber loop structure, enabling simultaneous demodulation of temperature and air pressure. We have developed a mathematical model that is closely monitored alongside the reflectance spectral structure. The sensor exhibits two distinct linear sensitivities for pressure and two different linear sensitivities for temperature, as revealed by our testing results. Specifically, microfiber mode interference demonstrates a temperature and pressure sensitivity of 160 pm/°C and 167/kPa, respectively, while the ring resonance effect yields a temperature and pressure sensitivity of 132 pm/°C and 62 pm/kPa, respectively. The maximum temperature resolution stands at 0.025°C, and the pressure resolution is 0.023 kPa. These findings are supported by the concept of a linear connection, which serves as the foundation of the transmission matrix and enables concurrent discrimination of air pressure and temperature. This sensor offers advantages due to its straightforward structure, high extinction ratio, superior electrical safety, and effective protection against electromagnetic interference.