7 April 2023 in Advanced Intelligent Systems
The continuum manipulator improves the intraocular robot flexibility during retinal surgery. Herein, a micro‐3‐degree of freedom (DOF) force sensor with a length of only 3.8 mm that can adjust the puncture angle during retinal vein cannulation (RVC) is proposed. Taking advantage of 3D printing technology, the optical fiber and injection line are embedded in the nitinol tube with flexible hinges to achieve integration of the force sensing and injection functions. A new fiber Bragg grating (FBG) configuration method and linear decoupling algorithm are also proposed herein. Static calibration experiments demonstrate excellent resolution of the force sensor, of less than 0.072 mN for transverse force and 0.738 mN for the axial force in the range from −20 to 20 mN. The proposed sensor is installed on a newly developed actuator, and an ex vivo experiment is performed on pig cadaver eyes. The interaction forces at each stage of the RVC are recorded in detail for the first time, further confirming the feasibility and effectiveness of the developed sensor for monitoring the RVC interaction forces.
24 April 2026 in Nature Communications
Intracochlear theranostics, particularly targeted drug delivery and microsampling, offers a promising solution to inner ear diseases. However, specialized medical devices remain limited by a fundamental design challenge imposed by anatomical constraints: balancing miniaturization, dexterity, and perceptive functionality. Here, we present a low–aspect-ratio, dual-segment continuum robot that integrates catheter, endoscopic and instrumental functions. Driven by antagonistic cables, the robot uses a transition-free backbone composed of saddle-shaped joints to achieve a minimum bending radius of 1.9 mm. Dual-segment motion decoupling yields programmable C-/S-shaped configurations, facilitating anatomical navigation. The microneedle, embedded in the central channel, serves as an end-effector with positioning accuracy of 17.9 ± 4.1 μm. Fiber Bragg grating sensors, mounted on the needle, measure axial force to estimate tool-tissue interaction. Validation is performed on cadavers and in vivo animals, demonstrating the feasibility of a transcanal, atraumatic robotic paradigm. Thus, this system provides a practical and accessible approach for early diagnosis and treatment, helping extend precision medicine to underserved areas.
4 April 2024 in IEEE/ASME Transactions on Mechatronics
Epiretinal membrane peel surgery requires the surgeon to perform precise operation on delicate tissue within the narrow space of the eye, which is considered as one of the most technically demanding procedures. Using surgical robots to assist surgeons in performing operations is a recognized development direction. The automatic microforceps, as a device mounted at the end of the robotic arm and directly in contact with the affected area, has been the subject of research by many scholars. However, current research has significant shortcomings in both the calibration algorithms for the sensors and the control methods for the microforceps. In this article, we introduce an automated microforceps designed for epiretinal membrane peeling procedures. Despite its compact radial dimension of just 20 mm, the jaw of the microforceps possesses the following two degrees of freedom (DOF): 1) rotation and 2) closure. Subsequently, we analyzed the changes in the physical model of the 3-DOF force sensor after its integration into the microforceps, leading us to propose a refined calibration algorithm tailored for our designed automated microforceps. Furthermore, we introduced a force-based adaptive clamping method suitable for variety of unknown thickness films. Both polyethylene terephthalate (PET) film experiments and generalization experiments demonstrated the stability and generalizability of the adaptive clamping method.
24 July 2023 in Advanced Intelligent Systems