Logan Wade

Logan Wade

Auto-generated profile, based on publicly available information

Logan Wade

Centre for the Analysis of Motion, Entertainment Research and Applications, University of Bath, Bath, UK

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2022 in PeerJ
Verified
Journal Article
Open access
PDF file
LWLogan Wade
Logan Wade
LNLaurie Needham
Laurie Needham
PMPolly McGuigan
Polly McGuigan
JBJames Bilzon
James Bilzon
Background: Markerless motion capture has the potential to perform movement analysis with reduced data collection and processing time compared to marker-based methods. This technology is now starting to be applied for clinical and rehabilitation applications and therefore it is crucial that users of these systems understand both their potential and limitations. This literature review aims to provide a comprehensive overview of the current state of markerless motion capture for both single camera and multi-camera systems. Additionally, this review explores how practical applications of markerless technology are being used in clinical and rehabilitation settings, and examines the future challenges and directions markerless research must explore to facilitate full integration of this technology within clinical biomechanics. Methodology: A scoping review is needed to examine this emerging broad body of literature and determine where gaps in knowledge exist, this is key to developing motion capture methods that are cost effective and practically relevant to clinicians, coaches and researchers around the world. Literature searches were performed to examine studies that report accuracy of markerless motion capture methods, explore current practical applications of markerless motion capture methods in clinical biomechanics and identify gaps in our knowledge that are relevant to future developments in this area. Results: Markerless methods increase motion capture data versatility, enabling datasets to be re-analyzed using updated pose estimation algorithms and may even provide clinicians with the capability to collect data while patients are wearing normal clothing. While markerless temporospatial measures generally appear to be equivalent to marker-based motion capture, joint center locations and joint angles are not yet sufficiently accurate for clinical applications. Pose estimation algorithms are approaching similar error rates of marker-based motion capture, however, without comparison to a gold standard, such as bi-planar videoradiography, the true accuracy of markerless systems remains unknown. Conclusions: Current open-source pose estimation algorithms were never designed for biomechanical applications, therefore, datasets on which they have been trained are inconsistently and inaccurately labelled. Improvements to labelling of open-source training data, as well as assessment of markerless accuracy against gold standard methods will be vital next steps in the development of this technology.

23 September 2019 in Scandinavian Journal of Medicine & Science in Sports
Verified
Journal Article
Closed access
PDF file
LWLogan Wade
Logan Wade
GLGlen A Lichtwark
Glen A Lichtwark
DFDominic James Farris
Dominic James Farris

9 November 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LWLogan Wade
Logan Wade
LNLaurie Needham
Laurie Needham
MEMurray Evans
Murray Evans
PMPolly McGuigan
Polly McGuigan
SCSteffi Colyer
Steffi Colyer
JBJames Bilzon
James Bilzon
This study examined if occluded joint locations, obtained from 2D markerless motion capture (single camera view), produced 2D joint angles with reduced agreement compared to visible joints, and if 2D frontal plane joint angles were usable for practical applications. Fifteen healthy participants performed over-ground walking whilst recorded by fifteen marker-based cameras and two machine vision cameras (frontal and sagittal plane). Repeated measures Bland-Altman analysis illustrated that markerless standard deviation of bias and limits of agreement for the occluded-side hip and knee joint angles in the sagittal plane were double that of the camera-side (visible) hip and knee. Camera-side sagittal plane knee and hip angles were near or within marker-based error values previously observed. While frontal plane limits of agreement accounted for 35–46% of total range of motion at the hip and knee, Bland-Altman bias and limits of agreement (-4.6–1.6 ± 3.7–4.2˚) were actually similar to previously reported marker-based error values. This was not true for the ankle, where the limits of agreement (± 12˚) were still too high for practical applications. Our results add to previous literature, highlighting shortcomings of current pose estimation algorithms and labelled datasets. As such, this paper finishes by reviewing methods for creating anatomically accurate markerless training data using marker-based motion capture data.

2 February 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LWLogan Wade
Logan Wade
GLGlen Lichtwark
Glen Lichtwark
DFDominic James Farris
Dominic James Farris
The preferred movement strategies that humans choose to produce work for movement are not fully understood. Previous studies have demonstrated an important contribution of elastic energy stored within the Achilles tendon (AT) during jumping. This study aimed to alter energy available for storage in the AT to examine changes in how jumpers distribute work among lower limb joints. Participants (n = 16) performed maximal and sub-maximal jumps under two paradigms, matched for increasing total work output by manipulating jump height or adding body mass. Motion capture and ground reaction force data were combined in an inverse dynamics analysis to compute ankle, knee and hip joint kinetics. Results demonstrated higher peak moments about the ankle joint with added body mass (+26 Nm), likely resulting in additional energy storage in the AT. Work at the ankle joint increased proportionally with added mass, maintaining a constant contribution (~64%) to total work that was not matched with increasing jump height (−14%). This implies greater energy storage and return by the AT with added mass but not with increased height. When total work during jumping is constant but energy stored in tendons is not, humans prioritise the use of stored elastic energy over muscle work.

26 January 2021 in PeerJ
Verified
Journal Article
Open access
PDF file
LFLuca Franco
Luca Franco
RSRaj Sengupta
Raj Sengupta
LWLogan Wade
Logan Wade
Dario CazzolaDario Cazzola
Dario Cazzola
Clinical assessment of spinal impairment in Axial Spondyloarthritis is currently performed using the Bath Ankylosing Spondylitis Metrological Index (BASMI). Despite being appreciated for its simplicity, the BASMI index lacks sensitivity and specificity of spinal changes, demonstrating poor association with radiographical range of motion (ROM). Inertial measurement units (IMUs) have shown promising results as a cost-effective method to quantitatively examine movement of the human body, however errors due to sensor angular drift have limited their application to a clinical space. Therefore, this article presents a wearable sensor protocol that facilitates unrestrained orientation measurements in space while limiting sensor angular drift through a novel constraint-based approach. Eleven healthy male participants performed five BASMI-inspired functional movements where spinal ROM and continuous kinematics were calculated for five spine segments and four spinal joint levels (lumbar, lower thoracic, upper thoracic and cervical). A Bland–Altman analysis was used to assess the level of agreement on range of motion measurements, whilst intraclass correlation coefficient (ICC), standardised error measurement, and minimum detectable change (MDC) to assess relative and absolute reliability. Continuous kinematics error was investigated through root mean square error (RMSE), maximum absolute error (MAE) and Spearman correlation coefficient (ρ). The overall error in the measurement of continuous kinematic measures was low in both the sagittal (RMSE = 2.1°), and frontal plane (RMSE = 2.3°). ROM limits of agreement (LoA) and minimum detectable change were excellent for the sagittal plane (maximum value LoA 1.9° and MDC 2.4°) and fair for lateral flexion (overall value LoA 4.8° and MDC 5.7°). The reliability analysis showed excellent level of agreement (ICC > 0.9) for both segment and joint ROM across all movements. The results from this study demonstrated better or equivalent accuracy than previous studies and were considered acceptable for application in a clinical setting. The protocol has shown to be a valuable tool for the assessment of spinal ROM and kinematics, but a clinical validation study on Axial Spondyloarthritis patients is required for the development and testing of a novel mobility index.

10 July 2024 in Scandinavian Journal of Medicine & Science in Sports
Verified
Journal Article
Open access
MMMarion Mundt
Marion Mundt
SCSteffi Colyer
Steffi Colyer
LWLogan Wade
Logan Wade
LNLaurie Needham
Laurie Needham
MEMurray Evans
Murray Evans
Jacqueline AldersonJacqueline Alderson
Jacqueline Alderson
Background: Two‐dimensional (2D) video is a common tool used during sports training and competition to analyze movement. In these videos, biomechanists determine key events, annotate joint centers, and calculate spatial, temporal, and kinematic parameters to provide performance reports to coaches and athletes. Automatic tools relying on computer vision and artificial intelligence methods hold promise to reduce the need for time‐consuming manual methods.Objective: This study systematically analyzed the steps required to automate the video analysis workflow by investigating the applicability of a threshold‐based event detection algorithm developed for 3D marker trajectories to 2D video data at four sampling rates; the agreement of 2D keypoints estimated by an off‐the‐shelf pose estimation model compared with gold‐standard 3D marker trajectories projected to camera's field of view; and the influence of an offset in event detection on contact time and the sagittal knee joint angle at the key critical events of touch down and foot flat.Methods: Repeated measures limits of agreement were used to compare parameters determined by markerless and marker‐based motion capture.Results: Results highlighted that a minimum video sampling rate of 100 Hz is required to detect key events, and the limited applicability of 3D marker trajectory‐based event detection algorithms when using 2D video. Although detected keypoints showed good agreement with the gold‐standard, misidentification of key events—such as touch down by 20 ms resulted in knee compression angle differences of up to 20°.Conclusion: These findings emphasize the need for de novo accurate key event detection algorithms to automate 2D video analysis pipelines.