Junjiroh Koyama

Junjiroh Koyama

Auto-generated profile, based on publicly available information

Junjiroh Koyama

Division of Cardiology Saiseikai Kumamoto Hospital Kumamoto Japan

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2014 in The American Journal of Cardiology
Verified
Journal Article
Closed access
HYHiroshige Yamabe
Hiroshige Yamabe
KOKen Okumura
Ken Okumura
JKJunjiroh Koyama
Junjiroh Koyama
HKHisanori Kanazawa
Hisanori Kanazawa
THTadashi Hoshiyama
Tadashi Hoshiyama
HOHisao Ogawa
Hisao Ogawa

25 October 2024 in Journal of the American Heart Association
Verified
Journal Article
Open access
KTKazunori Toyoda
Kazunori Toyoda
KKKengo Kusano
Kengo Kusano
YIYasuyuki Iguchi
Yasuyuki Iguchi
TITakanori Ikeda
Takanori Ikeda
IMItsuro Morishima
Itsuro Morishima
KOKen Okumura
Ken Okumura
Background: We aimed to quantify the incidence of atrial fibrillation (AF) in patients with cryptogenic stroke globally, as well as separately in patients in and outside of Japan, using an implantable loop recorder from a prospective, observational, Reveal LINQ Registry. Methods and Results: Patients developing cryptogenic stroke and monitored by implantable loop recorder for searching AF were studied. The primary end point was incidence of AF within 36 months after insertion. Secondary end points were recurrent ischemic stroke/transient ischemic attack and AF‐related treatment strategies. A total of 271 patients (61.6±14.3 years, 170 men, 60 from Japan) were enrolled from 12 countries. AF was detected in 28.2% at 36 months. The median time from enrollment to AF detection was 7.9 months. During the first 12 months, the AF detection rate slope was relatively steeper in the Japanese subgroup versus non‐Japanese patients. However, by 3 years, the cumulative incidence of AF detection did not differ between groups. Age was the only variable associated with AF detection (hazard ratio, 1.05 [95% CI, 1.02–1.07] per year), trending higher in older age groups. Of the 271 patients, 11 (4.1%) developed recurrent ischemic stroke/transient ischemic attack; AF was detected by implantable loop recorder in only 1 of these patients. Patients with detected AF were more commonly taking oral anticoagulation than those without AF at the last follow‐up (64.7% versus 25.3%, P <0.001). Conclusions: The rate of AF detection was similar to other studies in stroke populations monitored by implantable loop recorders, including CRYSTAL‐AF (Cryptogenic Stroke and Underlying Atrial Fibrillation), STROKE‐AF (Stroke of Unknown Cause and Underlying Atrial Fibrillation) and PER‐DIEM (Post‐Embolic Rhythm Detection With Implantable Versus External Monitoring). Patients with detected AF more commonly initiated anticoagulation than those without AF.

22 April 2013 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
HYHiroshige Yamabe
Hiroshige Yamabe
YTYasuaki Tanaka
Yasuaki Tanaka
KMKenji Morihisa
Kenji Morihisa
TUTakashi Uemura
Takashi Uemura
JKJunjiroh Koyama
Junjiroh Koyama
HOHisao Ogawa
Hisao Ogawa

1 December 2018 in Journal of Cardiology
Verified
Journal Article
Closed access
MIMiwa Ito
Miwa Ito
HYHiroshige Yamabe
Hiroshige Yamabe
JKJunjiroh Koyama
Junjiroh Koyama
HKHisanori Kanazawa
Hisanori Kanazawa
SKShozo Kaneko
Shozo Kaneko
KTKenichi Tsujita
Kenichi Tsujita

22 September 2026 in Journal of Arrhythmia
Verified
Journal Article
Open access
PDF file
HOHideharu Okamatsu
Hideharu Okamatsu
KOKen Okumura
Ken Okumura
KTKakeru Tomaru
Kakeru Tomaru
JMJunya Matsura
Junya Matsura
KNKodai Negishi
Kodai Negishi
HTHirofumi Tomita
Hirofumi Tomita
Background: In very high‐power (51–90 W), short‐duration (4 s) radiofrequency applications (QMODE+) using the QDOT MICRO catheter, the optimal power setting at the left atrial (LA) posterior wall adjacent to the esophagus for treating atrial fibrillation (AF) remains unclear. Objective: We evaluated the efficacy and safety of 60 W versus 90 W QMODE+ radiofrequency applications in the periesophageal region. Methods: Fifty AF patients were randomized into two groups based on the QMODE+ power applied to the periesophageal region: 60 W ( n = 24) and 90 W ( n = 26). We compared the incidence of residual conduction gaps in the periesophageal region and endoscopic esophageal lesions, as well as the 1‐year atrial tachyarrhythmia (AT) recurrence rate between the two groups. Results: Median contact force was significantly higher in the 60 W group than in the 90 W group (12.9 g [ IQR 10.2, 15.8] in the 60 W group and 10.9 g [ IQR 8.4, 14.2] in the 90 W group, p < 0.001). The rates of residual conduction gaps (8.3% and 11.5%, respectively, p = 1.00) and esophageal lesions (4.2% in each group) were similar between the two groups. The 1‐year AT recurrence rate did not significantly differ between the two groups (20.8% vs. 7.7%, respectively, p = 0.24). Conclusion: 60 W and 90 W QMODE+ RF applications for the periesophageal region achieved comparable rates of acute conduction block, endoscopy‐detected esophageal injury, and 12‐month AT recurrence‐free survival, although contact force was significantly higher in the 60 W group. Trial Registration: Japan Registry of Clinical Trials (jRCT); jRCT1072230115 (Registered on February 8, 2024)

22 October 2026 in European Heart Journal - Case Reports
Verified
Journal Article
Open access
MTMotomaro Tanaka
Motomaro Tanaka
TUTakashi Unoki
Takashi Unoki
HMHiroki Matsushita
Hiroki Matsushita
KSKeita Saku
Keita Saku
JKJunjiro Koyama
Junjiro Koyama
Background: Combined support with veno-arterial extracorporeal membrane oxygenation (VA-ECMO) and a micro-axial flow pump (mAFP), termed ECPELLA, provides systemic circulatory support with left ventricular (LV) unloading in refractory cardiogenic shock. VA-ECMO weaning may nevertheless be difficult when pulmonary vascular afterload is increased despite adequate LV unloading. Inhaled nitric oxide (iNO) selectively reduces pulmonary vascular resistance (PVR), but its role in this setting remains unclear. Case Summary: An 83-year-old woman with non-ST-segment elevation acute coronary syndrome underwent percutaneous coronary intervention. Persistent circulatory collapse required mAFP support followed by VA-ECMO. Despite adequate LV unloading, pulmonary artery catheterisation showed low pulmonary artery catheter-derived cardiac output (PAC-CO), low pulmonary capillary wedge pressure, and high calculated PVR, suggesting increased pulmonary vascular afterload rather than residual LV congestion. VA-ECMO flow reduction caused hypotension. After administration of iNO at 40 ppm, PAC-CO increased from 1.2 to 1.5 L/min and calculated PVR decreased from 11.7 to 8.0 Wood units while mechanical circulatory support settings and ventilator settings remained unchanged. VA-ECMO was removed on day 2 and the mAFP on day 3. The patient nevertheless died on day 4 from complications of severe lower-limb ischaemia. Discussion: A relative increase in PVR may hinder VA-ECMO weaning during ECPELLA support. iNO may facilitate device weaning in selected patients; however, a temporal association in a single case does not establish causality, clinical recovery, or a survival benefit.