1 October 1983 in The Journal of Physiology
6 April 2020 in Society Register
The profession of social work is dedicated to the betterment of society and to the protection of marginalized and vulnerable groups. The profession’s mission is detailed in the set of seven core values: service; social justice; dignity and work of the person; importance of human relationships; integrity; and competence. Relationships between people and among groups are the primary tools of social work assessment, intervention and evaluation. In the time of coronavirus and COVID-19, there are many challenges for professional practitioners to adhere to social work’s core values as well as to maintain their own health and welfare in a time of uncertain and rapidly changing situations. This paper will examine the challenges and innovations for each social work core value and present ideas for innovation and adaptation suited to these times. The paper will present challenges and innovations using examples of two community agencies providing services to people who are homeless and addicted. In summary we will offer some insights and expectations for the future of social work in the coming years, after this experience of coronavirus and COVID-19.
1 November 1981 in Acta Physiologica Scandinavica
1 May 1995 in American Journal of Respiratory and Critical Care Medicine
Many patients with spinal cord injury have paralysis of their expiratory muscles and, consequently, lack an effective cough. The purpose of the present study was to evaluate the utility of lower thoracic spinal cord stimulation (SCS) to activate the expiratory muscles. Studies were performed on 15 anesthetized dogs. A quadripolar stimulating electrode (Medtronic Model 3586) was inserted epidurally and on the ventral surface of the lower thoracic spinal cord. Changes in airway pressure, airflow, and internal intercostal and abdominal muscle length were monitored to assess the effects of electrical stimulation. Spinal stimulation applied at the T9-T10 spinal level provided maximal changes in airway pressure generation in preliminary experiments. All subsequent studies were therefore performed with the electrode positioned at this level. The expiratory muscles were stimulated supramaximally over a wide range of lung volumes which were expressed as the corresponding change in airway pressure. The pressure-generating capacity of the expiratory muscles was evaluated by the change in airway pressure produced by SCS during airway occlusion. Peak expiratory airflow was also monitored following release of occlusion. At FRC, deflation (-10 cm H2O) and inflation (+ 30 cm H2O), SCS resulted in positive airway pressures of 44 cm H2O +/- 4 SE, 28 cm H2O +/- 3 SE, and 82 cm H2O +/- 7 SE. The relationship between airway pressure expiratory airflow generation and lung volume was linear (slope = 1.34 +/- 0.04) over the entire vital capacity range. Our results indicate that: (1) a major portion of the expiratory muscles can be activated reproducibly and in concert by electrical stimulation, and (2) this technique may be a clinically useful method of restoring cough in spinal cord injured patients.
1 June 1999 in Journal of Applied Physiology
Large positive airway pressures (Paws) can be generated by lower thoracic spinal cord stimulation (SCS), which may be a useful method of restoring cough in spinal cord-injured patients. Optimal electrode placement, however, requires an assessment of the pattern of current spread during SCS. Studies were performed in anesthetized dogs to assess the pattern of expiratory muscle recruitment during SCS applied at different spinal cord levels. A multicontact stimulating electrode was positioned over the surface of the lower thoracic and upper lumbar spinal cord. Recording electromyographic electrodes were placed at several locations in the abdominal and internal intercostal muscles. SCS was applied at each lead, in separate trials, with single shocks of 0.2-ms duration. The intensity of stimulation was adjusted to determine the threshold for development of the compound action potential at each electrode lead. The values of current threshold for activation of each muscle formed parabolas with minimum values at specific spinal root levels. The slopes of the parabolas were relatively steep, indicating that the threshold for muscle activation increases rapidly at more cephalad and caudal sites. These results were compared with the effectiveness of SCS (50 Hz; train duration, 1–2 s) at different spinal cord levels to produce changes in Paw. Stimulation at the T9 and T10 spinal cord level resulted in the largest positive Paws with a single lead. At these sites, threshold values for activation of the internal intercostal (7–11th interspaces) upper portions of external oblique, rectus abdominis, and transversus abdominis were near their minimum. Threshold values for activation of the caudal portions of the abdominal muscles were high (>50 mA). Our results indicate that 1) activation of the more cephalad portions of the abdominal muscles is more important than activation of caudal regions in the generation of positive Paws and 2) it is not possible to achieve complete activation of the expiratory muscles with a single electrode lead by using modest current levels. In support of this latter conclusion, a two-electrode lead system results in more uniform expiratory muscle activation and significantly greater changes in Paw.
1 October 1999 in Journal of Applied Physiology
Lower thoracic spinal cord stimulation (SCS) results in the generation of large positive airway pressures (Paw) and may be a useful method of restoring cough in patients with spinal cord injury. The purpose of the present study was to assess the mechanical contribution of individual respiratory muscles to pressure generation during SCS. In anesthetized dogs, SCS was applied at different spinal cord levels by using a 15-lead multicontact electrode before and after sequential ablation of the external and internal obliques, transversus abdominis (TA), rectus abdominis, and internal intercostal muscles. Paw was monitored after tracheal occlusion. SCS at the T9 spinal cord level resulted in maximal changes in Paw (60 ± 3 cmH2O). Section of the oblique muscles resulted in a fall in Paw to 29 ± 2 cmH2O. After subsequent section of the rectus abdominis and TA, Paw fell to 25 ± 2 and 12 ± 1 cmH2O respectively. There was a small remaining Paw (4 ± 1 cmH2O) after section of the internal intercostal nerves. Stimulation with a two-electrode lead system (T9 + T13) resulted in significantly greater pressure generation compared with a single-electrode lead due to increased contributions from the obliques and transversus muscles. In a separate group of animals, Paw generation was monitored after section of the abdominal muscles and again after section of the external intercostal and levator costae muscles. These studies demonstrated that inspiratory intercostal muscle stimulation resulted in only a small opposing inspiratory action (≤3 cmH2O). We conclude that, during SCS, 1) contraction of the obliques and TA muscles makes the largest contribution to changes in Paw, and 2) stimulation with a two-electrode lead system results in more complete abdominal muscle activation and enhanced mechanical actions of the obliques and transversus muscles.