1 December 2018 in Ain Shams Engineering Journal
In this paper, an approach for optimal placement of D-STATCOM in mesh distribution systems using sensitivity approaches is proposed. The main contributions of the paper are as follows: (i) Optimal D-STATCOM placement based on the new voltage sensitivity index in mesh distribution system, (ii) optimal D-STATCOM size determination for seasonal loads with load growth scenario, (iii) comparison of D-STATCOM placement and size determination with the existing sensitivity methods, and (iv) impact of optimal D-STATCOM placement on voltage stability margin enhancement, energy loss reduction and cost of energy savings.The results of voltage profile improvement, reduction in power losses, reduction in cost of energy loss, improved voltage stability margin, cost of energy loss savings, installation cost of D-STATCOM and annual savings are obtained for UK 38 bus practical mesh distribution system
1 January 2015 in Procedia Computer Science
In this paper optimal location and size of D-STATCOM is determined for radial distribution networks for loss reduction, improvement of voltage profile and overall energy saving. The main contribution of the paper is: (i) Comparison of D-STATCOM allocation for radial distribution network using voltage stability index and power loss index approach (ii) D-STATCOM size calculation by variational technique for radial distribution system, (iii) percentage reduction in power losses with D-STATCOM placement. Based on the reduction in the power losses, the energy savings have been determined. The proposed method is tested for D-STATCOM allocation in IEEE 33-bus radial distribution systems. Results show the considerable reduction in losses and improvement in voltage profile
28 July 2019 in IETE Journal of Research
In this paper, a comprehensive review of the distribution system (DS) with Distributed Generation (DG) and Distribution Flexible AC Transmission System (D-FACTS) allocation for enhancement of voltage profiles, decrease in line losses with enrichment of feeder loading ability has been presented. The major intention is to give an idea about all the schemes for allocation of DG and D-FACTS proposed by researchers for balanced as well as unbalanced radial and mesh DS. To meet the demand for load growth, to find the best possible operation, to know alternative plans for future expansion with DG and D-FACTS and constant monitoring of steady-state performance, load flow analysis (LFA) is required. Therefore, a brief assessment of the LFA of the DS has been presented. Today, DG needs to be established by DG developers on distribution network operators' (DNO) recommendations due to its various techno-economic and environmental benefits. DG demands reactive power from the system, which results in low-voltage profiles as well as higher line losses. To sustain the voltage outline and to decrease the line loss, D-FACTS devices can be installed to offer reactive power support which in turn saves energy and the environment. This paper provided critical review and evaluation of DG and D-FACTS allocation in DNO-based DS and suggested the scope of future work in the emerging areas of competitive distribution system network operation.
1 December 2016 in Energy Procedia