Mehmet Burcin Unlu

Mehmet Burcin Unlu

Auto-generated profile, based on publicly available information

Mehmet Burcin Unlu

University of California, Tu and Yuen Center for Functional Onco-Imaging, Irvine, California 92697, USA

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2006 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
MUMehmet Burcin Unlu
Mehmet Burcin Unlu
OBOzlem Birgul
Ozlem Birgul
RSRoshanak Shafiiha
Roshanak Shafiiha
GGGultekin Gulsen
Gultekin Gulsen
ONOrhan Nalcioglu
Orhan Nalcioglu
We investigated the use of multifrequency diffuse optical tomography (MF-DOT) data for the reconstruction of the optical parameters. The experiments were performed in a 63mm diameter cylindrical phantom containing a 15mm diameter cylindrical object. Modulation frequencies ranging from 110MHz to 280MHz were used in the phantom experiments changing the contrast in absorption of the object with respect to the phantom while keeping the scattering value the same. The diffusion equation was solved using the finite element method. The sensitivity information from each frequency was combined to form a single Jacobian. The inverse problem was solved iteratively by minimizing the difference between the measurements and forward problem using single and multiple modulation frequency data. A multiparameter Tikhonov scheme was used for regularization. The phantom results show that the peak absorption coefficient in a region of interest was obtained with an error less then 5% using two-frequency reconstruction for absorption contrast values up to 2.2 times higher than background and 10% for the absorption contrast values larger than 2.2. The use of two-frequency data is sufficient to improve the quantitative accuracy compared with the single frequency reconstruction with appropriate selection of these frequencies.

1 January 2008 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
MUMehmet Burcin Unlu
Mehmet Burcin Unlu
YLYuting Lin
Yuting Lin
OBOzlem Birgul
Ozlem Birgul
ONOrhan Nalcioglu
Orhan Nalcioglu
GGGultekin Gulsen
Gultekin Gulsen
Diffuse optical tomography (DOT) can be used to localize and characterize a tumor based on endogenous contrast. Besides, using exogenous contrast agents may provide additional information for tumor detection and characterization. For example, it may be possible to use the dynamic behavior of indocyanine green (ICG) for differential diagnosis.1, 2, 3 ICG binds to plasma proteins; thus, it is confined to the vascular compartment and behaves as an intravascular contrast agent.

19 February 2008 in Applied Optics
Verified
Journal Article
Closed access
PDF file
MUMehmet Burcin Unlu
Mehmet Burcin Unlu
GGGultekin Gulsen
Gultekin Gulsen
There are two goals in this simulation study: (1) to show that the time variation of the bioluminescence source can cause artifacts in the tomographic images such that quantification and localization becomes impossible; and (2) to show that the a priori knowledge of the light kinetics can be used to eliminate these artifacts. These goals are motivated by the fact that the half-life of luciferase has been reported as 30 min to 2 h in vivo. We perform two-dimensional simulations. We consider a 40  mm diameter circular region with an inclusion of 6  mm diameter located 10  mm away from the center. The measurement data is simulated using a finite-element-based forward solver. We model the noncontact measurements such that four-wavelength data is collected from four 90° apart views. The results show that the ratio of the total imaging time to the half-life of the exponentially decaying bioluminescent source is the deciding factor in the reconstruction of the source. It is also demonstrated that a priori knowledge of the source kinetics is required to perform tomographic bioluminescence imaging of short half-life bioluminescent sources and the use of spatial a priori information alone is not adequate.

27 May 2008 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
MUMehmet Burcin Unlu
Mehmet Burcin Unlu
OBOzlem Birgul
Ozlem Birgul
GGGultekin Gulsen
Gultekin Gulsen
We investigated (1) the variability of indocyanine green kinetics (ICG) between different cases in the existence of random noise, changing the size of the imaging region, the location and the size of the inclusion, (2) the use of structural a priori information to reduce the variability. We performed two-dimensional simulation studies for this purpose. In the simulations, we used a two-compartmental model to describe the ICG transport and obtained pharmacokinetic parameters. The transfer constant and the rate constant showed a wide variation, i.e. 60% and 95%, respectively, when random Gaussian noise with a standard deviation of 1% in amplitude and 0.4 degrees in phase was added to data. Moreover, recovered peak ICG concentration and time to reach the peak concentration was different within different cases. When structural a priori information was used in the reconstructions, the variations in the transfer and the rate constant were reduced to 29%, 15%, respectively. As a result, although the recovered peak concentration was still case dependent, the variability of the shape of the kinetic curve was reduced.