Zeyuan Yu

Zeyuan Yu

Auto-generated profile, based on publicly available information

Zeyuan Yu

Institute of High Energy Physics

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
YHYongbo Huang
Yongbo Huang
JCJinfan Chang
Jinfan Chang
YCYaping Cheng
Yaping Cheng
ZCZhang Chen
Zhang Chen
JHJun Hu
Jun Hu
ZYZeyuan Yu
Zeyuan Yu

18 July 2022 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
FAF P An
F P An
WBW D Bai
W D Bai
ABA B Balantekin
A B Balantekin
MBM Bishai
M Bishai
SBS Blyth
S Blyth
DCDaya Bay Collaboration
Daya Bay Collaboration
This Letter reports the first measurement of high-energy reactor antineutrinos at Daya Bay, with nearly 9000 inverse beta decay candidates in the prompt energy region of 8–12 MeV observed over 1958 days of data collection. A multivariate analysis is used to separate 2500 signal events from background statistically. The hypothesis of no reactor antineutrinos with neutrino energy above 10 MeV is rejected with a significance of 6.2 standard deviations. A 29% antineutrino flux deficit in the prompt energy region of 8–11 MeV is observed compared to a recent model prediction. We provide the unfolded antineutrino spectrum above 7 MeV as a data-based reference for other experiments. This result provides the first direct observation of the production of antineutrinos from several high-Qβ isotopes in commercial reactors.

21 May 2025 in Physical Review Letters
Verified
Journal Article
Closed access
FAF P An
F P An
WBW D Bai
W D Bai
ABA B Balantekin
A B Balantekin
MBM Bishai
M Bishai
SBS Blyth
S Blyth
DCDaya Bay Collaboration
Daya Bay Collaboration
This Letter reports the precise measurement of the reactor antineutrino spectrum and flux based on the full dataset of 4.7×10^{6} inverse-beta-decay candidates collected at Daya Bay near detectors. Expressed in terms of the inverse-beta-decay yield per fission, the antineutrino spectra from all reactor fissile isotopes and the specific ^{235}U and ^{239}Pu isotopes are measured with 1.3%, 3%, and 8% uncertainties, respectively, near the 3 MeV spectrum peak in reconstructed energy, reaching the best precision in the world. The total antineutrino flux and isotopic ^{235}U and ^{239}Pu fluxes are precisely measured to be 5.84±0.07, 6.16±0.12, and 4.16±0.21 in units of 10^{-43} cm^{2}/fission. These measurements are compared with the Huber-Mueller model, the reevaluated conversion model based on the Kurchatov Institute measurement, and the latest summation model (SM2023). The Daya Bay flux shows good consistency with the Kurchatov Institute and SM2023 models but disagrees with the Huber-Mueller model. The Daya Bay spectrum, however, disagrees with all model predictions.

27 January 2026 in Chinese Physics C
Verified
Journal Article
Open access
ZYZeyuan Yu
Zeyuan Yu
The Jiangmen Underground Neutrino Observatory (JUNO) started physics data taking on 26~August~2025. JUNO consists of a 20-kton liquid scintillator central detector, surrounded by a 35 kton water pool serving as a Cherenkov veto, and almost 1000 m$^2$ of plastic scintillator veto on top. The detector is located in a shallow underground laboratory with an overburden of 1800 m.w.e. This paper presents the performance results of the detector, extensively studied during the commissioning of the water phase, the subsequent liquid scintillator filling phase, and the first physics runs. The liquid scintillator achieved an attenuation length of 20.6 m at 430 nm, while the high coverage PMT system and scintillator together yielded about 1785 photoelectrons per MeV of energy deposit at the detector centre, measured using the 2.223 MeV $\gamma$ from neutron captures on hydrogen with an Am-C calibration source. The reconstructed energy resolution is 3.4% for two 0.511~MeV $\gamma$ at the detector centre and 2.9\% for the 0.93 MeV quenched $^{214}$Po alpha decays from natural radioactive sources. The energy non-linearity is calibrated to better than 1%. Intrinsic contaminations of $^{238}$U and $^{232}$Th in the liquid scintillator are below 10$^{-16}$~g/g, assuming secular equilibrium. The water Cherenkov detector achieves a muon detection efficiency better than 99.9% for muons traversing the liquid scintillator volume. During the initial science runs, the data acquisition duty cycle exceeded 97.8%, demonstrating the excellent stability and readiness of JUNO for high-precision neutrino physics. Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Article funded by SCOAP3 and published under licence by Chinese Physical Society and the Institute of High Energy Physics of the Chinese Academy of Science and the Institute of Modern Physics of the Chinese Academy of Sciences and IOP Publishing Ltd.

1 August 2012 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
ZYZeyuan Yu
Zeyuan Yu
HLHaoqi Lu
Haoqi Lu
CYChanggen Yang
Changgen Yang
LWLingyu Wang
Lingyu Wang
MGMengyun Guan
Mengyun Guan
YWYifang Wang
Yifang Wang

1 July 2012 in Chinese Physics C
Verified
Journal Article
Closed access
PDF file
LWLing-Yu Wang
Ling-Yu Wang
HLHao-Qi Lu
Hao-Qi Lu
CYChang-Gen Yang
Chang-Gen Yang
ZYZe-Yuan Yu
Ze-Yuan Yu
JXJi-Lei Xu
Ji-Lei Xu
YWYi-Fang Wang
Yi-Fang Wang