Yu Wang

Yu Wang

Auto-generated profile, based on publicly available information

Yu Wang

Peking University First Hospital

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2020 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
LQLongtao Qi
Longtao Qi
BXBeiyu Xu
Beiyu Xu
CLChunde Li
Chunde Li
YWYu Wang
Yu Wang
Background: Halo traction has been used as an adjunctive method in the treatment of severe spinal deformities. But there are few reports on the clinical efficacy of halo-pelvic traction (HPT) in the treatment of severe spinal deformities complicated with respiratory dysfunction. This study was to evaluate the clinical efficacy and complications associated with pre-operative HPT in the treatment of severe spinal deformities with respiratory dysfunction. Methods: Thirty patients with severe spinal deformities complicated with respiratory dysfunction treated with short-term pre-operative HPT were retrospectively reviewed. Inclusion criteria were: (1) patients with severe kyphoscoliosis (coronal Cobb angle or kyphosis angle ≥100°) and respiratory failure, (2) patients undergoing HPT until posterior fusion surgery. All patients underwent general anesthesia for HPT application, which the pelvic ring used in this study was a half-ring, and the rods were all placed on the anterolateral side of the truck. Results: The major coronal curve scoliosis averaged 116.00 ± 16.70° and was reduced to 63.23 ± 14.00° after HPT, 46.33 ± 10.70° after surgery. The major kyphosis was 102.40 ± 27.67° and was reduced to 52.23 ± 14.16° after HPT, 42.0 ± 11.92° after surgery. A significantly increased FVC was observed after HPT (p < 0.001), with a significantly improved FVC% (p < 0.001). Similarly, a significantly increased FEV1 was also observed (p < 0.001), with a significantly improved FEV1% (p < 0.001). Conclusion: This study indicated that the modified HPT could be used to help patients with severe spinal deformities complicated with respiratory dysfunction achieve significant correction in both the coronal and sagittal deformities during the pre-operative treatment period along with improved respiratory function and in the absence of severe complications.

1 January 2012 in The Spine Journal
Verified
Journal Article
Closed access
YWYu Wang
Yu Wang
CBCody E. Bünger
Cody E. Bünger
YZYanqun Zhang
Yanqun Zhang
CWChunsen Wu
Chunsen Wu
EHEbbe S. Hansen
Ebbe S. Hansen

6 August 2024 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
TWTianqi Wu
Tianqi Wu
XLXilong Liu
Xilong Liu
YZYao Zhao
Yao Zhao
LQLongtao Qi
Longtao Qi
High-precision dynamic 3-D reconstruction technology is highly valuable in industrial automation applications, including defect detection, visual measurement, and grasp planning. Presently, predominant 3-D reconstruction for industrial applications requires projecting a pattern sequence, introducing complexities to positioning and measurement in dynamic conditions. We proposed a single-shot dense 3-D reconstruction framework for industrial tasks in response. This work is valuable in the following two aspects. 1) We proposed a design scheme of structured light patterns and developed a multifrequency phase decoding network to extract the wrapped phase from the multifrequency fringe pattern. These unique phase combinations can be used as a robust feature for disparity optimization and stereo matching. 2) We created a dataset with 3000 scenes and their high-precision wrapped phase ground truth. Experiments demonstrate that our proposed method significantly outperforms existing single-shot structured light reconstruction methods with high precision and adaptability. Thus, this framework has significant potential application in industrial automation.

5 November 2011 in European Spine Journal
Verified
Journal Article
Open access
PDF file
YWYu Wang
Yu Wang
CBCody Eric Bünger
Cody Eric Bünger
YZYanqun Zhang
Yanqun Zhang
EHEbbe Stender Hansen
Ebbe Stender Hansen
The aim of this study was to investigate whether or not post-op curve behaviour differs due to different choices of lowest instrumented vertebra (LIV) with reference to lumbar apical vertebra (LAV) in Lenke 3C and 6C scoliosis. We reviewed all the AIS cases surgically treated in our institution from 2002 through 2008. Inclusion criteria were as follows: (1) patients with Lenke 3C or 6C scoliosis who were treated with posterior pedicle screw-only constructs; (2) 2-year radiographic follow-up. All the included patients were categorized into three groups based on the relative position of LIV and LAV: Group A—the LIV was above the LAV; Group B—the LIV was at the LAV; Group C—the LIV was below the LAV. All the radiographic parameters were then compared among the groups. All image data were available in our picture archiving and communication systems. Standing anteroposterior (AP) and lateral digital radiographs were reviewed at four times (pre-op, post-op, 3-month and 2-year). In each standing AP radiograph, centre sacral vertical line (CSVL, the vertical line that bisects the proximal sacrum) was first drawn, followed by measuring T1-CSVL, LIV-CSVL, (LIV + 1)-CSVL, LAV-CSVL and thoracic AV-CSVL distance. In addition, the Cobb angles of major thoracic and lumbar curves were measured at the four times and the correction rates were then calculated. Of the 278 patients reviewed, 40 met the inclusion criteria; 11 of these were included in Group A (LIV above LAV), another 11 in Group B (LIV at LAV) and the remaining 18 in Group C (LIV below LAV). At 2-year follow-up, the lumbar vertebrae such as LIV, LIV + 1 and LAV were all more deviated than before surgery in Group A (LIV above LAV), whereas in Group B and C (LIV at and below LAV) they were all less deviated than before surgery. No significant differences were found in thoracic or lumbar correction rate, global coronal balance and incidence rate of trunk shift among the three groups. In conclusion, in Lenke 3C and 6C scoliosis, post-op lumbar curve behaviour differs due to different choices of LIV with reference to LAV, that is, the deviation of lumbar curve improves when the LIV is either at or below the LAV but deteriorates when the LIV is above the LAV. Although the greatest correction occurs when the LIV is below the LAV, choosing LAV as LIV can still be the optimal option in certain cases, since it can yield similar correction while preserving more lumbar mobility and growth potential.

26 January 2025 in Postgraduate Medicine
Verified
Journal Article
Closed access
LYLei Yue
Lei Yue
JZJianming Zhang
Jianming Zhang
CLChao Li
Chao Li
ZWZiqi Wang
Ziqi Wang
LQLongtao Qi
Longtao Qi
HSHaolin Sun
Haolin Sun
This study aims to clarify hematological parameters, transfusion requirements, and adverse events of preoperative intravenous (IVIS) versus oral iron supplementation (OIS) in elective surgery patients. We conducted a comprehensive literature search across multiple databases up to 10 December 2023. Twelve RCTs involving 930 participants met our eligibility criteria. Our analysis focused on post-treatment hemoglobin levels, changes in hemoglobin from baseline, ferritin levels, hemoglobin attainment rates, transfusion requirements, and adverse events. We employed the random-effects model for data synthesis, calculating pooled standard mean differences (SMD) or mean differences (MD) or risk ratios (RR) with 95% confidence intervals (CI). Methodological quality was assessed using the Cochrane ROB 2 tool and Jadad score. The GRADE approach evaluated the confidence in effect estimates. IVIS significantly improved post-treatment hemoglobin levels (MD = 0.77 g/dL, 95% CI [0.30 to 1.23]), hemoglobin increments (MD = 0.69 g/dL, 95% CI [0.01 to 1.37]), and ferritin levels (MD = 260.03 ng/mL, 95% CI [119.65 to 400.42]) compared to OIS. IVIS also led to a higher hemoglobin attainment rate (RR = 1.88, 95% CI [1.24 to 2.86]). No significant differences were noted in transfusion rates or volumes. IVIS was associated with fewer digestive (RR = 0.10, 95% CI [0.05 to 0.22]; I2 = 0%) but more pain-related adverse events (RR = 7.79, 95% CI [1.78 to 34.07]; I2 = 0%). Hospital stay durations and mortality rates were similar between the two groups. IVIS offers a superior improvement in hematological parameters for elective surgery patients but not reducing transfusion needs compared to OIS. While IVIS has fewer digestive adverse events, it increases pain-related complications. These findings highlight the importance of personalized approaches in selecting iron supplementation methods, carefully balancing time, efficacy, and adverse event profiles. PROSPERO CRD42023483284.