Seyoung Shin

Seyoung Shin

Auto-generated profile, based on publicly available information

Seyoung Shin

School of Chemical Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2024 in Sensors & Diagnostics
Verified
Journal Article
Open access
PDF file
MYMinyeong Yoon
Minyeong Yoon
YLYullim Lee
Yullim Lee
SLSeungju Lee
Seungju Lee
YCYoungwook Cho
Youngwook Cho
DKDamee Koh
Damee Koh
SCSoo-Yeon Cho
Soo-Yeon Cho
In this review, we provide a comprehensive overview of the latest advancements in diagnostic sensor design using nIR fluorescent SWCNTs and suggest potential directions for technological developments for real-world applications.

23 December 2024 in ACS Nano
Verified
Journal Article
Closed access
SLSeungju Lee
Seungju Lee
GRGwanghui Ryu
Gwanghui Ryu
SSSeyoung Shin
Seyoung Shin
WKWoojin Kim
Woojin Kim
MYMinyeong Yoon
Minyeong Yoon
SCSoo-Yeon Cho
Soo-Yeon Cho

6 July 2025 in ACS Nano
Verified
Journal Article
Closed access
SLSeungju Lee
Seungju Lee
JCJeongmin Cha
Jeongmin Cha
SSSeyoung Shin
Seyoung Shin
MYMinyeong Yoon
Minyeong Yoon
GSGabriel Sánchez-Velázquez
Gabriel Sánchez-Velázquez
SCSoo-Yeon Cho
Soo-Yeon Cho

5 April 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
YLYeon Soo Lee
Yeon Soo Lee
SSSeyoung Shin
Seyoung Shin
GKGyun Ro Kang
Gyun Ro Kang
SLSiyeon Lee
Siyeon Lee
DKDa Wan Kim
Da Wan Kim
CPChanghyun Pang
Changhyun Pang
Molecular tracing of extremely low amounts of biofluids is vital for precise diagnostic analysis. Although optical nanosensors for real-time spatiotemporal molecular tracing exist, integrating them into simple devices that capture low-volume fluids on rough, dynamic surfaces remains challenging. We present a bioinspired 3D microstructured patch monolithically integrated with optical nanosensors (3D MIN) for real-time, multivariate molecular tracing of ultralow-volume fluids. Inspired by tree frog toe pads, the 3D MIN features soft, hexagonally aligned pillars and microchannels for conformal adhesion and targeted fluid management. Embedding near-infrared fluorescent single-walled carbon nanotube nanosensors in a hydrogel enables simultaneous fluid capture and detection. Softening the elastomer microarchitecture and optimizing water management promote stable adhesion on wet biosurfaces, allowing rapid collection of ultralow-volume fluids (~0.1 µL/min·cm²). We demonstrate real-time, remote sweat analysis with ≥75 nL volumes collected in 45 s, without exercise or iontophoresis, showcasing high biocompatibility and efficient spatiotemporal molecular tracing.

4 December 2024 in ACS Sensors
Verified
Journal Article
Closed access
MYMinyeong Yoon
Minyeong Yoon
SSSeyoung Shin
Seyoung Shin
SLSeungju Lee
Seungju Lee
Joohoon KangJoohoon Kang
Joohoon Kang
XGXun Gong
Xun Gong
SCSoo-Yeon Cho
Soo-Yeon Cho

7 April 2025 in Nanoscale
Verified
Journal Article
Open access
PDF file
MYMinyeong Yoon
Minyeong Yoon
SSSeyoung Shin
Seyoung Shin
SLSeungju Lee
Seungju Lee
SCSoo-Yeon Cho
Soo-Yeon Cho
Real-time monitoring of uric acid (UA) is essential for preventing and managing chronic diseases. While enzymatic methods are the clinical standard, they are limited by slow reaction times and strict environmental requirements. Enzyme-free sensors offer alternatives but face challenges in analyte selectivity and clear optical signal readouts. In this study, we developed an enzyme-free UA detection method based on corona phase molecular recognition (CoPhMoRe). We developed a near-infrared (NIR) optical nanosensor by functionalizing single-walled carbon nanotubes (SWCNTs) with single-stranded DNA (ssDNA). Through high-throughput screening, we identified the optimal corona of the sensor as (AAT)10/SWCNT and further optimized it with studying the pH effects to account for the natural pH variation in urine. To facilitate point-of-care (POC) application, we integrated the corona nanosensor with an optical paper strip, achieving a rapid and intense turn-on NIR response up to 4 times stronger when exposed to urine samples containing UA concentrations ranging from 5.7 to 500 μM. Moreover, the corona nanosensor-integrated paper strip exhibited reliable performance even under harsh conditions of 70% relative humidity and 40 °C. This study demonstrates the enzyme-free UA detection capability of SWCNT-based CoPhMoRe in complex biofluids, establishing its potential for future application as an optical test strip in POC diagnostics.