Dang Khoa Pham

Dang Khoa Pham

Auto-generated profile, based on publicly available information

Dang Khoa Pham

Industrial and Systems Engineering Department, North Carolina A&T State University, Greensboro, NC, USA

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2026 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
TNTrong Nhan Nguyen
Trong Nhan Nguyen
VDVu Hoang Minh Doan
Vu Hoang Minh Doan
TVTan Hung Vo
Tan Hung Vo
DPDang Khoa Pham
Dang Khoa Pham
DVDinh Dat Vu
Dinh Dat Vu
JOJunghwan Oh
Junghwan Oh
Scanning acoustic microscopy (SAM) plays a critical role in nondestructive inspection of semiconductor and industrial materials; however, deep-layer SAM images often suffer from severe attenuation-induced noise and the absence of clean reference data, significantly limiting reliable defect analysis. To address these challenges, this article proposes a hierarchical diffusion-based denoising framework that transfers structural and statistical knowledge from high-quality top-layer SAM images to restore degraded deep-layer images. A physics-guided synthetic data generation pipeline, combining Gaussian degradation modeling and unpaired domain transfer, is introduced to enable effective training. A hybrid Transformer–Mamba diffusion architecture is also constructed to jointly capture local spatial structures and long-range depth-dependent dependences, while a depthwise latent extraction strategy enhances the separation of noise and structural features. Extensive experiments on benchmark datasets and industrial SAM images demonstrate that the proposed approach achieves better performance on both reference-based metrics (peak signal-to-noise ratio, structural similarity index measure, learned perceptual image patch similarity, and Fréchet inception distance) and no-reference evaluation, while significantly improving downstream defect segmentation accuracy using the segment anything model. Although the proposed model has a higher parameter count than competing methods, the results indicate its strong potential for practical SAM-based industrial inspection.

31 August 2025 in JMIR Preprints
Verified
Preprint
Open access
Minh H. N. LeMinh H. N. Le
Minh H. N. Le
DNDang Nguyen
Dang Nguyen
HRHeath Rutledge-Jukes
Heath Rutledge-Jukes
TPThuan Quang Phan
Thuan Quang Phan
TTTien Truong
Tien Truong
PHPhat Huynh
Phat Huynh
BACKGROUND Echocardiography reports in routine care often encode clinical reasoning as ordinal valve-lesion severity. The EchoNotes database derived from MIMIC III harmonizes such report text into a reproducible ordinal schema across echocardiograms, enabling population-scale analysis of report-level change between successive exams. However, most prior work has focused on image-based automation (e.g., ejection fraction estimation) or label extraction from text, with far less attention to how these ordinal severities change over time. Critically, apparent change is confounded by follow-up interval (\mathrm{\Delta t}) and care setting (inpatient vs outpatient), yet the literature offers few \mathrm{\Delta t}-aware summaries or nonparametric, \mathrm{\Delta t}-standardized setting comparisons. OBJECTIVE The study conducted a secondary data analysis of the de‑identified EchoNotes dataset to provide an evidence‑based description of how ordinal valve-lesion severity levels change between successive examinations and to determine how apparent change depends on \mathrm{\Delta t} and care setting using observed data with uncertainty quantification. METHODS We analyzed the EchoNotes dataset that has 45,794 reports. For each patient and lesion of interest (aortic valve (AV) stenosis, AV regurgitation, mitral valve (MV) stenosis, and MV regurgitation), we chronologically ordered reports, formed successive within‑patient pairs, and retained evaluable ordinal states (0 = normal, 1 = mild, 2 = moderate, 3 = severe). We computed row‑normalized next‑visit transition matrices summarizing, for each baseline state, the distribution of the subsequent state. To make visit timing explicit, we stratified transitions by \mathrm{\Delta t} (< 7, 7-30, 30-90, and ≥ 90 days). Care‑setting differences were estimated by assigning pairs to inpatient or outpatient status. Because settings differ in follow‑up timing, we produced a nonparametric \mathrm{\Delta t}‑standardized contrast. Within each baseline state, inpatient and outpatient pairs were reweighted to a shared \mathrm{\Delta t} bin mix before computing difference matrices (inpatient minus outpatient). Uncertainty was quantified with a subject‑level bootstrap. RESULTS Left-sided lesion codes were frequently evaluable (AV regurgitation—72.7%, AV stenosis—65.2%, MV regurgitation—67.8%, MV stenosis—37.0%). The ordinal association analysis witnessed the strongest correlation between right-ventricle dysfunction and chamber enlargement (ρ ≈ 0.62). In \mathrm{\Delta t}-stratified next-visit transition matrices, diagonal persistence dominated short intervals, with off-diagonal movement rising at longer \mathrm{\Delta t} (most for MV regurgitation and least for AV stenosis). Care-setting comparisons showed more movement among inpatients in the non-\mathrm{\Delta t}-standardized matrices (e.g., 35% inpatient vs 53% outpatient for AV stenosis when concerning the moderate-to-moderate transitions), but \mathrm{\Delta t}-standardization attenuated most differences, with residual contrasts largely confined to higher-severity AV regurgitation where inpatients were more likely to improve from worse states. CONCLUSIONS We propose an evidence based workflow that yields interpretable maps of how report level echo severities behave in routine care. Our \mathrm{\Delta t} aware results separate visit scheduling from biology, support fairer comparisons across services, and provide practical priors for simulation, cohort design, and evaluation of future multimodal or AI systems against an observational baseline.