23 February 2024 in Science Advances
Prokaryotes encode multiple distinct anti-phage defense systems in their genomes. However, the impact of carrying a multitude of defense systems on phage resistance remains unclear, especially in a clinical context. Using a collection of antibiotic-resistant clinical strains of Pseudomonas aeruginosa and a broad panel of phages, we demonstrate that defense systems contribute substantially to defining phage host range and that overall phage resistance scales with the number of defense systems in the bacterial genome. We show that many individual defense systems target specific phage genera and that defense systems with complementary phage specificities co-occur in P. aeruginosa genomes likely to provide benefits in phage-diverse environments. Overall, we show that phage-resistant phenotypes of P. aeruginosa with at least 19 phage defense systems exist in the populations of clinical, antibiotic-resistant P. aeruginosa strains.
25 July 2022 in Bioelectrochemistry
CSClarissa Amaral da Silva
Electroporation has become a powerful tool for nonviral delivery of various biomolecules such as nucleic acids, proteins, and chemotherapeutic drugs to virtually any living cell by exposing the cell membrane to an intense pulsed electric field. Different multiphysics and multiscale models have been developed to describe the phenomenon of electroporation and predict molecular transport through the electroporated membrane. In this paper, we critically examine the existing mechanistic, single-cell models which allow spatially and temporally resolved numerical simulations of electroporation-induced transmembrane transport of small molecules by confronting them with different experimental measurements. Furthermore, we assess whether any of the proposed models is universal enough to describe the associated transmembrane transport in general for all the different pulse parameters and small molecules used in electroporation applications. We show that none of the tested models can be universally applied to the full range of experimental measurements. Even more importantly, we show that none of the models has been compared to sufficient amount of experimental data to confirm the model validity. Finally, we provide guidelines and recommendations on how to design and report experiments that can be used to validate an electroporation model and how to improve the development of mechanistic models.
1 January 2021 in Biochimica et Biophysica Acta (BBA) - Biomembranes
Transient physical disruption of cell membranes by electric pulses (or electroporation) has significance in biomedical and biological applications requiring the delivery of exogenous (bio)molecules to living cells. We demonstrate that actin networks regulate the cell membrane permeability during electroporation. Disruption of actin networks increases the uptake of membrane-impermeable molecules such as propidium iodide during electroporation. Our experiments at different temperatures ranging from 11 °C to 37 °C show that molecular uptake during electroporation increases with temperature. Furthermore, by examining the temperature-dependent kinetics of propidium iodide uptake, we infer that the activation energy barrier of electroporation is lowered when the actin networks are disrupted. Our numerical calculations of transmembrane voltage show that the reduced activation energy barrier for the cells with disrupted actin is not a consequence of the changes in transmembrane voltage associated with changes in the cell shape due to the disruption of actin, indicating that this could be due to changes in membrane mechanical properties. Our results suggest that the current theoretical models of electroporation should be advanced further by including the contributions of the cytoskeletal networks on the cell membrane permeability during the delivery of exogenous materials.
31 May 2019 in Scientific Reports
We study the role of a biomimetic actin network during the application of electric pulses that induce electroporation or electropermeabilization, using giant unilamellar vesicles (GUVs) as a model system. The actin cortex, a subjacently attached interconnected network of actin filaments, regulates the shape and mechanical properties of the plasma membrane of mammalian cells, and is a major factor influencing the mechanical response of the cell to external physical cues. We demonstrate that the presence of an actin shell inhibits the formation of macropores in the electroporated GUVs. Additionally, experiments on the uptake of dye molecules after electroporation show that the actin network slows down the resealing process of the permeabilized membrane. We further analyze the stability of the actin network inside the GUVs exposed to high electric pulses. We find disruption of the actin layer that is likely due to the electrophoretic forces acting on the actin filaments during the permeabilization of the GUVs. Our findings on the GUVs containing a biomimetic network provide a step towards understanding the discrepancies between the electroporation mechanism of a living cell and its simplified model of the empty GUV.
1 June 2018 in Journal of Biomechanics
22 December 2017 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Echocardiographic determination of multicomponent blood flow dynamics in the left ventricle remains a challenge. In this paper, we compare contrast enhanced, high frame rate (HFR) (1000 frames/s) echo-particle image velocimetry (ePIV) against optical particle image velocimetry (oPIV, gold standard), in a realistic left ventricular (LV) phantom. We find that ePIV compares well to oPIV, even for the high velocity inflow jet (normalized RMSE = 9% ± 1%). In addition, we perform the method of proper orthogonal decomposition, to better qualify and quantify the differences between the two modalities. We show that ePIV and oPIV resolve very similar flow structures, especially for the lowest order mode with a cosine similarity index of 86%. The coarser resolution of ePIV does result in increased variance and blurring of smaller flow structures when compared to oPIV. However, both modalities are in good agreement with each other for the modes that constitute the bulk of the kinetic energy. We conclude that HFR ePIV can accurately estimate the high velocity diastolic inflow jet and the high energy flow structures in an LV setting.