11 October 2021 in BMJ Open
Objectives The measurement of visceral fat (VF) is clinically important for the identification of individuals at high risk of visceral obesity-related health conditions. Bioelectrical impedance analysis (BIA) is a widely available and frequently used body composition assessment method, but there have been few validation studies for the measurement of VF. This validation study investigated agreement between BIA and CT for the assessment of VF in adults. Design Cross-sectional study. Setting Between 2015 and 2016 in China. Participants A total of 414 adults (119 men and 295 women) aged 40–82 years. Primary and secondary outcome measures CT-visceral fat area (VFA) was derived at the L2-3 and umbilicus level and VFA cut-offs for visceral obesity applied. BIA measurements of visceral fat level were compared with CT VFA findings using scatter plots and receiver operator characteristic (ROC) curves. Results Scatter plots showed poor agreement between BIA and CT-derived visceral fat measurements in both sexes (R=0.387–0.636). ROC curves gave optimum figures for sensitivity and specificity of 65% and 69% in women and 76% and 70% in men, respectively, for BIA to discriminate between adults with normal levels of VF and those with visceral obesity determined by CT. Conclusion BIA has limited accuracy for the assessment of VF in adults in practice when compared with the criterion method.
14 July 2026 in Bone & Joint Research
This study aimed to compare the agreement between phantom-based (PB-QCT) and phantomless (PL-QCT) quantitative CT bone mineral density (BMD) measurements, and their predictive utility for subsequent fractures in postmenopausal women following percutaneous kyphoplasty (PKP) for osteoporotic vertebral compression fractures (OVCFs). In this prospective cohort study, 185 OVCF patients underwent lumbar CT with synchronous phantom calibration. BMD was measured via PB-QCT, PL-QCT (using subcutaneous adipose tissue (SAT), psoas muscle, or dual-tissue calibration), and vertebral Hounsfield units (vHU). Agreement was assessed via Bland-Altman analysis, and fracture prediction via Cox regression. Dual-tissue PL-QCT showed the highest agreement with PB-QCT (absolute bias: 0.04 to 2.18 mg/cm³). However, PB-QCT demonstrated superior predictive power: per 1-SD decrease, it predicted 20% to 22% increased risk of spinal fractures (adjusted HR = 1.21, p = 0.032) and any-site fractures (HR = 1.20, p = 0.043), maintaining significance after multivariable adjustment. Despite high agreement - especially between PB-QCT and dual-tissue PL-QCT - PB-QCT demonstrated modest but consistent advantages in predicting subsequent fractures over PL-QCT and vHU. These results reinforce the essential role of standardized phantom calibration for accurate fracture risk stratification in post-PKP patients, while also supporting the potential use of PL-QCT and vHU as opportunistic screening tools in settings where phantom calibration is not feasible.