Pavel Klaput

Pavel Klaput

Auto-generated profile, based on publicly available information

Pavel Klaput

VSB-TU Ostrava , Department of quality management , 17. listopadu 2172/15 Czech Republic

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Measurement Science Review
Verified
Journal Article
Open access
PDF file
Lenka CepovaLenka Cepova
Lenka Cepova
AKAndrea Kovacikova
Andrea Kovacikova
RCRobert Cep
Robert Cep
PKPavel Klaput
Pavel Klaput
OMOndrej Mizera
Ondrej Mizera
The submitted article focuses on a detailed explanation of the average and range method (Automotive Industry Action Group, Measurement System Analysis approach) and of the honest Gauge Repeatability and Reproducibility method (Evaluating the Measurement Process approach). The measured data (thickness of plastic parts) were evaluated by both methods and their results were compared on the basis of numerical evaluation. Both methods were additionally compared and their advantages and disadvantages were discussed. One difference between both methods is the calculation of variation components. The AIAG method calculates the variation components based on standard deviation (then a sum of variation components does not give 100 %) and the honest GRR study calculates the variation components based on variance, where the sum of all variation components (part to part variation, EV & AV) gives the total variation of 100 %. Acceptance of both methods among the professional society, future use, and acceptance by manufacturing industry were also discussed. Nowadays, the AIAG is the leading method in the industry.

31 October 2012 in Quality Innovation Prosperity
Verified
Journal Article
Open access
PDF file
JPJiří Plura
Jiří Plura
PKPavel Klaput
Pavel Klaput
Influence of the Interaction Between Parts and Appraisers on the Results of Repeatability and Reproducibility Analysis

31 July 2018 in MATEC Web of Conferences
Verified
Journal Article
Open access
PKPavel Klaput
Pavel Klaput
DVDavid Vykydal
David Vykydal
Evaluate the quality of this measurement system is possible by using multiple methods, which are described in the methodology guides for evaluation of the measurement system quality. Within these methods, values of different indicators are evaluated. This paper deals with the cross tabulation method and foremost Kappa indicator. More specifically is examined the effect of the number of used nonconforming samples on explanatory power of this indicator. The effect on the kappa values is examined from several aspects that must be taken into account during evaluation of the quality of measurement system for attributive quality characteristics.