A high-accuracy optical distance meter with a mode-locked femtosecond laser is proposed for distance measurements in a 310-m-long optical tunnel. We measured the phase shift of the optical beat component between longitudinal modes of a mode-locked laser. A high resolution of 50 µm at 240-m distance was obtained without cyclic error correction. The group refractive index of air is automatically extracted to an accuracy of 6 parts per million (ppm) by two-color measurement with the pulses of fundamental and second-harmonic wavelengths. Finally, an absolute mechanical distance of 240 m was obtained to within 8-ppm accuracy by use of a series of beat frequencies with the advantage of a wide range of intermode frequency, together with the results of the two-color measurement.
Single-mode X couplers and three-dimensional waveguides are fabricated in transparent glasses by use of an unamplified femtosecond laser generating energies of up to 100 nJ. Changing fabrication parameters such as power and scanning speed permits creation of waveguides with a wide range of structures and refractive-index difference. Optical coherence tomography shows large refractive-index changes of up to in the waveguides; these changes are consistent with guided mode analysis.
We have developed a fiber-based frequency comb system consisting of a simple mode-locked fiber laser and a backward pumping amplifier combined with a highly nonlinear fiber with a short zero-dispersion wavelength. As a result, the signal to noise ratio of the obtained carrier-envelope-offset frequency beat is larger than 45 dB at a bandwidth of 100 kHz. Furthermore, we have succeeded in measuring the optical frequencies of a 1542-nm acetylene-stabilized laser and a 532-nm iodine-stabilized Nd:YAG laser continuously for more than one week using the fiber-based comb system. The long-term measurement revealed that the frequency stability of the iodine-stabilized laser was 5.7×10-15 with 100 000 s averaging.
We demonstrate that fiber-based frequency combs with multi-branch configurations can transfer both linewidth and frequency stability to another wavelength at the millihertz level. An intra-cavity electro-optic modulator is employed to obtain a broad servo bandwidth for repetition rate control. We investigate the relative linewidths between two combs using a stable continuous-wave laser as a common reference to stabilize the repetition rate frequencies in both combs. The achieved energy concentration to the carrier of the out-of-loop beat between the two combs was 99% and 30% at a bandwidth of 1 kHz and 7.6 mHz, respectively. The frequency instability of the comb was 3.7×10−16 for a 1 s averaging time, improving to 5-8×10−19 for 10000 s. We show that the frequency noise in the out-of-loop beat originates mainly from phase noise in branched optical fibers.
The repetition rate and carrier-envelope phase offset frequencies of a turnkey, all-fiber-based continuum generator were phase locked to a hydrogen maser. The frequency of the hydrogen maser was calibrated with a highly stable cesium atomic clock, and therefore a fully phase-locked optical frequency comb with well-defined absolute frequencies was obtained. In contrast with the commonly used Ti:sapphire-laser-based systems, we have accomplished a fully turnkey system with no user-adjustable parts. To evaluate the performance of this novel system, we performed absolute frequency measurements in the telecommunications region and at 1064 nm and compared them with our traditional Ti:sapphire-based comb.