Chao-Min Wu

Chao-Min Wu

Auto-generated profile, based on publicly available information

Chao-Min Wu

Department of Electrical Engineering, National Central University, Taoyuan, Taiwan

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2023 in IEEE Transactions on Cognitive and Developmental Systems
Verified
Journal Article
Open access
EHEnoch Hsin-Ho Huang
Enoch Hsin-Ho Huang
RCRong Chao
Rong Chao
YTYu Tsao
Yu Tsao
CWChao-Min Wu
Chao-Min Wu
ElectrodeNet, a deep learning based sound coding strategy for the cochlear implant (CI), is proposed to emulate the advanced combination encoder (ACE) strategy by replacing the conventional envelope detection using various artificial neural networks. The extended ElectrodeNet-CS strategy further incorporates the channel selection (CS). Network models of deep neural network (DNN), convolutional neural network (CNN), and long short-term memory (LSTM) were trained using the Fast Fourier Transformed bins and channel envelopes obtained from the processing of clean speech by the ACE strategy. Objective speech understanding using short-time objective intelligibility (STOI) and normalized covariance metric (NCM) was estimated for ElectrodeNet using CI simulations. Sentence recognition tests for vocoded Mandarin speech were conducted with normal-hearing listeners. DNN, CNN, and LSTM based ElectrodeNets exhibited strong correlations to ACE in objective and subjective scores using mean squared error (MSE), linear correlation coefficient (LCC) and Spearman’s rank correlation coefficient (SRCC). The ElectrodeNet-CS strategy was capable of producing N-of-M compatible electrode patterns using a modified DNN network to embed maxima selection, and to perform in similar or even slightly higher average in STOI and sentence recognition compared to ACE. The methods and findings demonstrated the feasibility and potential of using deep learning in CI coding strategy.

12 November 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
EHEnoch Hsin-Ho Huang
Enoch Hsin-Ho Huang
CWChao-Min Wu
Chao-Min Wu
HLHung-Ching Lin
Hung-Ching Lin
Three cochlear implant (CI) sound coding strategies were combined in the same signal processing path and compared for speech intelligibility with vocoded Mandarin sentences. The three CI coding strategies, biologically-inspired hearing aid algorithm (BioAid), envelope enhancement (EE), and fundamental frequency modulation (F0mod), were combined with the advanced combination encoder (ACE) strategy. Hence, four singular coding strategies and four combinational coding strategies were derived. Mandarin sentences with speech-shape noise were processed using these coding strategies. Speech understanding of vocoded Mandarin sentences was evaluated using short-time objective intelligibility (STOI) and subjective sentence recognition tests with normal-hearing listeners. For signal-to-noise ratios at 5 dB or above, the EE strategy had slightly higher average scores in both STOI and listening tests compared to ACE. The addition of EE to BioAid slightly increased the mean scores for BioAid+EE, which was the combination strategy with the highest scores in both objective and subjective speech intelligibility. The benefits of BioAid, F0mod, and the four combinational coding strategies were not observed in CI simulation. The findings of this study may be useful for the future design of coding strategies and related studies with Mandarin.

1 May 2008 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
CWChao-Min Wu
Chao-Min Wu
YLYi-Syuan Lin
Yi-Syuan Lin
The aim of this study is to use functional magnetic resonance imaging (fMRI) method to find neural correlates on Chinese speech production. Three young normal adults (mean age 24 yrs) produced four tone Chinese characters "ma1, ma2, ma3, and ma4" in four ways: (A) normal speech, (B) mouthing speech, (C) unarticulated speech, (D) internal speech, and "ma1, ma1, ma1, and ma1" for the condition (E) normal speech. The fMRI results showed that the areas associated with the control of breathing for speech, vocalization, and hearing were the sensorimotor cortex, supplementary motor area, the superior temporal gyrus, the cerebellum, parietal association area, and the lingual gyrus. The areas associated with articulation were the sensorimotor cortex, the cerebellum, the inferior frontal gyrus, anterior and posterior cingulate gyrus, and the precuneus. The areas associated with tone variation were found in bilateral basal ganglia, hippocampal formation, and parietal association area, and the left pre‐motor area, middle occipital gyrus, and the right cerebellum, superior temporal gyrus, and midbrain. Neural correlates of speech production and Chinese tone were all related to the cerebellum. In summary, our preliminary results showed the cerebellum plays an important role on Chinese speech production.

26 May 2023 in arXiv
Verified
Preprint
Open access
PDF file
EHEnoch Hsin-Ho Huang
Enoch Hsin-Ho Huang
RCRong Chao
Rong Chao
YTYu Tsao
Yu Tsao
CWChao-Min Wu
Chao-Min Wu
ElectrodeNet, a deep learning based sound coding strategy for the cochlear implant (CI), is proposed to emulate the advanced combination encoder (ACE) strategy by replacing the conventional envelope detection using various artificial neural networks. The extended ElectrodeNet-CS strategy further incorporates the channel selection (CS). Network models of deep neural network (DNN), convolutional neural network (CNN), and long short-term memory (LSTM) were trained using the Fast Fourier Transformed bins and channel envelopes obtained from the processing of clean speech by the ACE strategy. Objective speech understanding using short-time objective intelligibility (STOI) and normalized covariance metric (NCM) was estimated for ElectrodeNet using CI simulations. Sentence recognition tests for vocoded Mandarin speech were conducted with normal-hearing listeners. DNN, CNN, and LSTM based ElectrodeNets exhibited strong correlations to ACE in objective and subjective scores using mean squared error (MSE), linear correlation coefficient (LCC) and Spearman's rank correlation coefficient (SRCC). The ElectrodeNet-CS strategy was capable of producing N-of-M compatible electrode patterns using a modified DNN network to embed maxima selection, and to perform in similar or even slightly higher average in STOI and sentence recognition compared to ACE. The methods and findings demonstrated the feasibility and potential of using deep learning in CI coding strategy.

1 October 2023 in The Journal of the Acoustical Society of America
Verified
Journal Article
Open access
CWChao-Min Wu
Chao-Min Wu
KPKang-Cheng Peng
Kang-Cheng Peng
XYX Ming Yang
X Ming Yang
The wireless automatic auditory brainstem response measurement system developed in the previous research uses Kalman filter with exponential weight averaging method (Kalman filter with EWA) to filter signal and used the differential method to detect the Wave V of ABR. However, the signals are too noisy to be accurately determined. Therefore, this study compares the Wavelet Kalman filter and Moving average to the Kalman filter with EWA, and the fitted parametric peak (FPP) to the differential method, respectively. The simulation results showed that the signal-to-noise ratio of ABR is the highest after Wavelet Kalman filtering, and the audiologist can mark the waves III and V of ABR the most. The latency of the wave V detected by FPP was used to calculate the Pearson product-moment correlation coefficient with the audiologist’s manual mark. The two latencies are highly correlated, and the correlation coefficient is higher than the differential method. Therefore, the Wavelet-Kalman filter and FPP algorithm were implemented in the AABR measurement system. To evaluate the accuracy of the algorithm in this study, subjective experiments were conducted with four normal hearing subjects. The Mann-Whitney U test was used to test thedifference between the average value of automatic detection and reproducibility.

7 April 2015 in Disability and Rehabilitation: Assistive Technology
Verified
Journal Article
Closed access
PDF file
DSDahnial Syauqy
Dahnial Syauqy
CWChao-Min Wu
Chao-Min Wu
OSOnny Setyawati
Onny Setyawati
The purpose of this study is to develop a tool to assist speech therapy and rehabilitation, which focused on automatic scoring based on the comparison of the patient’s speech with another normal speech on several aspects including pitch, vowel, voiced–unvoiced segments, strident fricative and sound intensity. The pitch estimation employed the use of cepstrum-based algorithm for its robustness; the vowel classification used multilayer perceptron (MLP) to classify vowel from pitch and formants; and the strident fricative detection was based on the major peak spectral intensity, location and the pitch existence in the segment. In order to evaluate the performance of the system, this study analyzed eight patient’s speech recordings (four males, four females; 4–58-years-old), which had been recorded in previous study in cooperation with Taipei Veterans General Hospital and Taoyuan General Hospital. The experiment result on pitch algorithm showed that the cepstrum method had 5.3% of gross pitch error from a total of 2086 frames. On the vowel classification algorithm, MLP method provided 93% accuracy (men), 87% (women) and 84% (children). In total, the overall results showed that 156 tool’s grading results (81%) were consistent compared to 192 audio and visual observations done by four experienced respondents.