Rafael Kranzer

Rafael Kranzer

Auto-generated profile, based on publicly available information

Rafael Kranzer

PTW-Freiburg, Freiburg D-79115

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2020 in Medical Physics
Verified
Journal Article
Open access
PDF file
RKRafael Kranzer
Rafael Kranzer
DPDaniela Poppinga
Daniela Poppinga
JWJan Weidner
Jan Weidner
ASAndreas Schüller
Andreas Schüller
THThomas Hackel
Thomas Hackel
BPBjörn Poppe
Björn Poppe
Purpose: The ion collection efficiency of vented ionization chambers has been investigated in an ultra‐high dose‐per‐pulse (DPP) electron beam. The role of the chamber design and the electric field strength in the sensitive air volume have been evaluated.Methods: An advanced Markus chamber and three specially designed parallel plate air‐filled ionization chambers (EWC: End Window Chamber) with varying electrode distance of 0.5, 1, and 2 mm have been investigated. Their ion collection efficiencies were determined experimentally using two methods: extrapolation of Jaffé plots and comparison against a DPP‐independent reference detector. The latter was achieved by calibrating a current transformer against alanine dosimeters. All measurements were performed in a 24 MeV electron beam with DPP values between 0.01 and 3 Gy. Additionally, the numerical approach introduced by Gotz et al. was implemented taking into account space charge effects at these ultra‐high DPPs. The method has been extended to obtain time‐resolved and position‐dependent electric field distortions within the air cavity.Results: The ion collection efficiency of the investigated ionization chambers drops significantly in the ultra‐high DPP range. The extent of this drop is dependent on the electrode distance, the applied chamber voltage and thus the field strength in the sensitive air volume. For the Advanced Markus chamber, a good agreement between the experimental, numerical and the results of Petersson et al. could be shown. Using the three EWCs with different electrode spacing, an improvement of the ion collection efficiency and a reduction of the polarity effect with decreasing electrode distance could be demonstrated. Furthermore, the results revealed that the determination of the ion collection efficiency from the Jaffé plots and therefore also from two‐voltage method typically underestimate the ion collection efficiency in the region of high dose‐per‐pulse (3 to 130 mGy) and overestimate the ion collection efficiency at ultra‐high dose‐per‐pulse (>1 Gy per pulse).Conclusions: In this work, the ion collection efficiency determined with different methods and ionization chambers have been compared and discussed. As expected, an increase of the electric field in the ionization chamber, either by applying a higher bias voltage or a reduction of the electrode distance, improves the ion collection efficiency and also reduces the polarity effect. For the Advanced Markus chamber, the experimental results obtained by comparison against a reference agree well with the numerical solution. Based on these results, it seems possible to keep the recombination loss less than or equal to 5% up to a dose‐per‐pulse of 3 Gy with an appropriately designed ionization chamber, which corresponds to the level accepted in conventional radiotherapy dosimetry protocols.

21 March 2022 in Physics in Medicine & Biology
Verified
Journal Article
Open access
RKR Kranzer
R Kranzer
ASA Schüller
A Schüller
ABA Bourgouin
A Bourgouin
THT Hackel
T Hackel
DPD Poppinga
D Poppinga
BPB Poppe
B Poppe
Objective. With increasing investigation of the so-called FLASH effect, the need for accurate real time dosimetry for ultra-high dose rates is also growing. Considering the ultra-high dose-per-pulse (DPP) necessary to produce the ultra-high dose rates for investigations of the FLASH effect, real time dosimetry is a major challenge. In particular, vented ionization chambers, as used for dosimetry in conventional radiotherapy, show significant deviations from linearity with increasing DPP. This is due to recombination losses in the sensitive air volume. Solid state detectors could be an alternative. Due to their good stability of the response with regard to the accumulated dose, diamond detectors such as the microDiamond could be suitable here. The aims of this work are to investigate the response of microDiamond and adapted microDiamond prototypes in ultra-high DPP electron beams, to understand the underlying effects and to draw conclusions for further detector developments. Approach. For the study, an electron beam with a DPP up to 6.5 Gy and a pulse duration of 2.5 μ s was used to fulfill the conditions under which the FLASH effect was observed. As a dose rate-independent reference, alanine dosimeters were used. Main Results. It has been shown that the commercially available microDiamond detectors have limitations in terms of linearity at ultra-high DPP. But this is not an intrinsic limitation of the detector principle. The deviations from linearity were correlated with the series resistance and the sensitivity. It could be shown that the linear range can be extended towards ultra-high DPP range by reducing the sensitivity in combination with a low series resistance of the detectors. Significance. The work shows that synthetic single crystal diamond detectors working as Schottky photodiodes are in principle suitable for FLASH-RT dosimetry at electron linear accelerators.

14 August 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
MMMarco Marinelli
Marco Marinelli
FMFabio di Martino
Fabio di Martino
DSDamiano Del Sarto
Damiano Del Sarto
JPJake Harold Pensavalle
Jake Harold Pensavalle
GFGiuseppe Felici
Giuseppe Felici
GRGianluca Verona Rinati
Gianluca Verona Rinati
Objective. A reliable determination of the instantaneous dose rate (I-DR) delivered in FLASH radiotherapy treatments is believed to be crucial to assess the so-called FLASH effect in preclinical and biological studies. At present, no detectors nor real-time procedures are available to do that in ultra high dose rate (UH-DR) electron beams, typically consisting of μ s pulses characterized by I-DRs of the order of MGy/s. A dosimetric system is proposed possibly overcoming the above reported limitation, based on the recently developed flashDiamond (fD) detector (model 60025, PTW-Freiburg, Germany). Approach. A dosimetric system is proposed, based on a flashDiamond detector prototype, properly modified and adapted for very fast signal transmission. It was used in combination with a fast transimpedance amplifier and a digital oscilloscope to record the temporal traces of the pulses delivered by an ElectronFlash linac (SIT S.p.A., Italy). The proposed dosimetric systems was investigated in terms of the temporal characteristics of its response and the capability to measure the absolute delivered dose and instantaneous dose rate (I-DR). A ‘standard’ flashDiamond was also investigated and its response compared with the one of the specifically designed prototype. Main results . Temporal traces recorded in several UH-DR irradiation conditions showed very good signal to noise ratios and rise and decay times of the order of a few tens ns, faster than the ones obtained by the current transformer embedded in the linac head. By analyzing such signals, a calibration coefficient was derived for the fD prototype and found to be in agreement within 1% with the one obtained under reference 60 Co irradiation. I-DRs as high as about 2 MGy s −1 were detected without any undesired saturation effect. Absolute dose per pulse values extracted by integrating the I-DR signals were found to be linear up to at least 7.13 Gy and in very good agreement with the ones obtained by connecting the fD to a UNIDOS electrometer (PTW-Freiburg, Germany). A good short term reproducibility of the linac output was observed, characterized by a pulse-to-pulse variation coefficient of 0.9%. Negligible differences were observed when replacing the fD prototype with a standard one, with the only exception of a somewhat slower response time for the latter detector type. Significance. The proposed fD-based system was demonstrated to be a suitable tool for a thorough characterization of UH-DR beams, providing accurate and reliable time resolved I-DR measurements from which absolute dose values can be straightforwardly derived.

14 October 2022 in Physics in Medicine & Biology
Verified
Journal Article
Open access
ABAlexandra Bourgouin
Alexandra Bourgouin
THThomas Hackel
Thomas Hackel
MMMarco Marinelli
Marco Marinelli
RKRafael Kranzer
Rafael Kranzer
ASAndreas Schüller
Andreas Schüller
RKRalf-Peter Kapsch
Ralf-Peter Kapsch
Objective . The aim of the presented study is to evaluate the dose response of the PTB’s secondary standard system, which is based on alanine and electron spin resonance (ESR) spectroscopy measurement, in ultra-high-pulse-dose-rate (UHPDR) electron beams. Approach . The alanine dosimeter system was evaluated in the PTB’s UHPDR electron beams (20 MeV) in a range of 0.15–6.2 Gy per pulse. The relationship between the obtained absorbed dose to water per pulse and the in-beamline charge measurement of the electron pulses acquired using an integrating current transformer (ICT) was evaluated. Monte Carlo simulations were used to determine the beam quality conversion and correction factors required to perform alanine dosimetry. Main results . The beam quality conversion factor from the reference quality 60 Co to 20 MeV obtained by Monte Carlo simulation, 1.010(1), was found to be within the standard uncertainty of the consensus value, 1.014(5). The dose-to-water relative standard uncertainty was determined to be 0.68% in PTB’s UHPDR electron beams. Significance . In this investigation, the dose-response of the PTB’s alanine dosimeter system was evaluated in a range of dose per pulse between 0.15 Gy and 6.2 Gy and no evidence of dose-response dependency of the PTB’s secondary standard system based on alanine was observed. The alanine/ESR system was shown to be a precise dosimetry system for evaluating absorbed dose to water in UHPDR electron beams.

19 April 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
CFCeleste Fleta
Celeste Fleta
GPGiulio Pellegrini
Giulio Pellegrini
PGPhilippe Godignon
Philippe Godignon
FRFaustino Gómez Rodríguez
Faustino Gómez Rodríguez
JPJosé Paz-Martín
José Paz-Martín
ASAndreas Schüller
Andreas Schüller
Objective. The successful implementation of FLASH radiotherapy in clinical settings, with typical dose rates >40 Gy s −1 , requires accurate real-time dosimetry. Approach. Silicon carbide (SiC) p–n diode dosimeters designed for the stringent requirements of FLASH radiotherapy have been fabricated and characterized in an ultra-high pulse dose rate electron beam. The circular SiC PiN diodes were fabricated at IMB-CNM (CSIC) in 3 μ m epitaxial 4H-SiC. Their characterization was performed in PTB’s ultra-high pulse dose rate reference electron beam. The SiC diode was operated without external bias voltage. The linearity of the diode response was investigated up to doses per pulse (DPP) of 11 Gy and pulse durations ranging from 3 to 0.5 μ s. Percentage depth dose measurements were performed in ultra-high dose per pulse conditions. The effect of the total accumulated dose of 20 MeV electrons in the SiC diode sensitivity was evaluated. The temperature dependence of the response of the SiC diode was measured in the range 19 °C–38 °C. The temporal response of the diode was compared to the time-resolved beam current during each electron beam pulse. A diamond prototype detector (flashDiamond) and Alanine measurements were used for reference dosimetry. Main results. The SiC diode response was independent both of DPP and of pulse dose rate up to at least 11 Gy per pulse and 4 MGy s −1 , respectively, with tolerable deviation for relative dosimetry (<3%). When measuring the percentage depth dose under ultra-high dose rate conditions, the SiC diode performed comparably well to the reference flashDiamond. The sensitivity reduction after 100 kGy accumulated dose was <2%. The SiC diode was able to follow the temporal structure of the 20 MeV electron beam even for irregular pulse estructures. The measured temperature coefficient was (–0.079 ± 0.005)%/°C. Significance. The results of this study demonstrate for the first time the suitability of silicon carbide diodes for relative dosimetry in ultra-high dose rate pulsed electron beams up to a DPP of 11 Gy per pulse.

8 April 2022 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
ABAlexandra Bourgouin
Alexandra Bourgouin
AKAdrian Knyziak
Adrian Knyziak
MMMarco Marinelli
Marco Marinelli
RKRafael Kranzer
Rafael Kranzer
ASAndreas Schüller
Andreas Schüller
RKRalf-Peter Kapsch
Ralf-Peter Kapsch
Purpose. This investigation aims to present the characterisation and optimisation of an ultra-high pulse dose rate (UHPDR) electron beam at the PTB facility in Germany. A Monte Carlo beam model has been developed for dosimetry study for future investigation in FLASH radiotherapy and will be presented. Material and methods. The 20 MeV electron beams generated by the research linear accelerator has been characterised both in-beamline with profile monitors and magnet spectrometer, and in-water with a diamond detector prototype. The Monte Carlo model has been used to investigate six different setups to enable different dose per pulse (DPP) ranges and beam sizes in water. The properties of the electron radiation field in water have also been characterised in terms of beam size, quality specifier R 50 and flatness. The beam stability has also been studied. Results. The difference between the Monte-Carlo simulated and measured R 50 was smaller than 0.5 mm. The simulated beam sizes agreed with the measured ones within 2 mm. Two suitable setups have been identified for delivering reference UHPDR electron beams. The first one is characterised by a SSD of 70 cm, while in the second one an SSD of 90 cm is used in combination with a 2 mm aluminium scattering plates. The two set-ups are quick and simple to install and enable an expected overall DPP range from 0.13 Gy up to 6.7 Gy per pulse. Conclusion. The electron beams generated by the PTB research accelerator have shown to be stable throughout the four-months length of this investigation. The Monte Carlo models have shown to be in good agreement for beam size and depth dose and within 1% for the beam flatness. The diamond detector prototype has shown to be a promising tool to be used for relative measurements in UHPDR electron beams.