Jason P. Schott

Jason P. Schott

Auto-generated profile, based on publicly available information

Jason P. Schott

Department of Cardiovascular Medicine Beaumont Hospital, Royal Oak Royal Oak Michigan USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2020 in Echocardiography
Verified
Journal Article
Open access
PDF file
JSJason P. Schott
Jason P. Schott
AMAmy N. Mertens
Amy N. Mertens
RBRichard Bloomingdale
Richard Bloomingdale
TOThomas F. O’connell
Thomas F. O’connell
MGMichael J. Gallagher
Michael J. Gallagher
AAAmr E. Abbas
Amr E. Abbas
Introduction Severe acute respiratory syndrome coronavirus‐2 (SARS‐CoV‐2)–infected patients commonly have elevated troponin and D‐dimer levels, but limited imaging exists to support most likely etiologies in efforts to avoid staff exposure. The purpose of this study was to report transthoracic echocardiographic (TTE) findings in SARS‐CoV‐2 patients with correlating troponin and D‐dimer levels. Methods We identified 66 SARS‐CoV‐2 patients (mean age 60 ± 15.7 years) admitted within a large, eight‐hospital healthcare system over a 6‐week period with a TTE performed. TTE readers were blinded to laboratory data with intra‐observer and inter‐observer analysis assessed. Results Sixty‐six of 1780 SARS‐CoV‐2 patients were included and represented a high‐risk population as 38 (57.6%) were ICU‐admitted, 47 (71.2%) had elevated D‐dimer, 41 (62.1%) had elevated troponin, and 25 (37.9%) died. Right ventricular (RV) dilation was present in 49 (74.2%) patients. The incidence and average D‐dimer elevation was similar between moderate/severe vs. mild/no RV dilation (69.6% vs 67.6%, P = 1.0; 3736 ± 2986 vs 4141 ± 3351 ng/mL, P = .679). Increased left ventricular (LV) wall thickness was present in 46 (69.7%) with similar incidence of elevated troponin and average troponin levels compared to normal wall thickness (66.7% vs 52.4%, P = .231; 0.88 ± 1.9 vs 1.36 ± 2.4 ng/mL, P = .772). LV dilation was rare (n = 6, 9.1%), as was newly reduced LV ejection fraction (n = 2, 3.0%). Conclusion TTE in SARS‐CoV‐2 patients is scarce, technically difficult, and reserved for high‐risk patients. RV dilation is common in SARS‐CoV‐2 but does not correlate with elevated D‐dimer levels. Increased LV wall thickness is common, while newly reduced LV ejection fraction is rare, and neither correlates with troponin levels.

15 November 2022 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Open access
JSJason P. Schott
Jason P. Schott
ARAkash Rusia
Akash Rusia
SLStephen Lynch
Stephen Lynch
ATAdam Tawney
Adam Tawney
SMSyed F. Mustafa
Syed F. Mustafa
IHIvan D. Hanson
Ivan D. Hanson
Introduction: Percutaneous left ventricular assist device (pLVAD) explant remains nonstandardized with potential complications of bleeding and thrombosis. Explant settings include percutaneous techniques in the catheterization laboratory (CL), manually at bedside (MB), and surgically in the operating room (OR).Objective: Identify high‐risk features for explant‐related complications, including indication for support, setting, and technique.Methods: Postexplant bleeding and thrombosis/limb ischemia were identified following pLVAD removals over 2 years at a multicenter healthcare system.Results: Of 156 patients, bleeding (n = 26 [17%]) and thrombosis (n = 9 [6%]) occurred more often in patients with the peripheral arterial disease (PAD), female gender, anemia, and cardiogenic shock. OR explants had a higher combined endpoint (4/8 [50%]) versus CL (23/133 [17%], p < 0.05) driven by transfusion. There was no difference between OR versus MB (5/15 [33%], p = 0.66) or CL versus MB (p = 0.62). In shock patients, there was no difference between CL (7/30 [23%]) versus MB (5/15 [33%], p = 0.5) and OR (4/7 [57%], p = 0.16); or MB versus OR (p = 0.38). Average length of stay was significantly lower in the CL group versus MB and OR (3.6 ± 33.2 vs. 18.4 ± 10.9 vs. 28.1 ± 15.8 days, p < 0.0001). Preclosure in shock patients (5/25 [20%] vs. 11/27 [41%], p = 0.1383) and crossover balloon occlusion technique (9/44 [16%] vs. 25/112 [22%]; p = 1) were not associated with higher combined endpoints versus control.Conclusion: Risk factors for pLVAD explant complications include PAD, female gender, and cardiogenic shock. There was no difference in complication rates between explant settings among cardiogenic shock patients, but shorter length of stay when performed in the CL. There was no difference in complication rates when using the crossover balloon occlusion technique.

20 January 2021 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
JSJason P. Schott
Jason P. Schott
SDSimon R. Dixon
Simon R. Dixon
JGJames A. Goldstein
James A. Goldstein