Microcantilevers featuring separate built-in actuation and displacement sensing capabilities allow effective and simple implementation of control methods, opening a pathway to achieving higher scan speeds in tapping-mode atomic force microscopy. Such active cantilevers are a significant milestone to eventually obtain video-rate on-chip atomic force microscopes (AFMs) that can even surpass the functionality and imaging speed of their macroscale counterparts at a significantly lower cost. In this brief, we present an active AFM cantilever with an on-chip actuator and two built-in displacement sensors, designed to be integrated into on-chip AFMs. The common feedthrough problem present in this type of architecture is addressed by a differential sensing configuration, and the revealed dynamics are used for the system identification. A positive position feedback controller is designed to actively tailor the Q factor of the cantilever. The imaging performance of the microcantilever with and without Q control is compared by attenuating the cantilever's Q factor from 177 to 15 using the feedback loop. A common artifact in high-speed scans, the parachuting effect, is mitigated, rendering higher imaging speeds achievable.
7 April 2020 in Journal of Microelectromechanical Systems
We present a microelectromechanical system (MEMS)-based closed-loop force sensor, capable of measuring bidirectional forces along one axis of motion. The device comprises an on-chip electrothermal displacement sensor and electrostatic actuators. It features a voltage-controlled stiffness-adjustment mechanism, providing the user with an additional means of tuning the sensor's characteristics. This silicon-on-insulator device is an improvement on our previous design, offering a better dynamic range and a less complex calibration process. The sensor is fabricated based on a standard SOI MEMS process. It is then fully characterized and instrumented with a feedback controller. The closed-loop characterization reveals a 1σ-resolution of 4.74 nN and a force sensing range of -211.7μN to 211.5μN, leading to a dynamic range of 92.9 dB. [2019-0248]
23 June 2021 in Journal of Vacuum Science & Technology B
A scanning tunneling microscope (STM) combines unique capabilities in imaging and spectroscopy with atomic precision, and it can obtain energy-resolved spectroscopic data with atomic resolution. In this paper, we utilize a recently proposed modification to the STM feedback control loop to acquire high quality d2I/dV2 images. We have developed a constant differential conductance imaging method by closing the STM feedback loop with a high precision dI/dV measurement. In this mode, the tip’s vertical position is adjusted so as to keep the differential conductance constant during raster scanning of the surface. Based on this imaging mode, we propose a new technique to acquire fast and reliable scanning tunneling spectroscopy (STS) data simultaneously with the imaging.
28 May 2020 in Journal of Vacuum Science & Technology B
The controlled formation of dangling bond structures on a H-terminated silicon surface is the first step in an atomically precise method of fabrication of silicon quantum electronic devices. An ultrahigh vacuum scanning tunneling microscope (STM) tip is used to selectively desorb hydrogen atoms from a Si(100)-2×1:H surface by injecting electrons with the sample held at a positive bias voltage. The authors propose a lithography method that allows the STM to operate under negative bias imaging conditions and simultaneously desorb H atoms as required. A high frequency signal is added to the negative bias voltage to deliver the required energy for hydrogen removal. The resulting current at this frequency and its harmonics are filtered to minimize their effect on the operation of the STM’s feedback control loop. The authors show that the chance of tip-sample crash during the lithography process is reduced by employing this method. They also demonstrate that this approach offers a significant potential for controlled and precise removal of H atoms from a H-terminated silicon surface and thus may be used for the fabrication of practical silicon-based atomic-scale devices.