Qing Ji

Qing Ji

Auto-generated profile, based on publicly available information

Qing Ji

Accelerator Technology and Applied Physics Division, Lawrence Berkeley National Laboratory 1 , Berkeley, California 94720, USA

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2020 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
AMAurora Cecilia Araujo Martinez
Aurora Cecilia Araujo Martinez
QJQing Ji
Qing Ji
SPSoren Prestemon
Soren Prestemon
XWXiaorong Wang
Xiaorong Wang
GCGeorfrey Humberto Israel Maury Cuna
Georfrey Humberto Israel Maury Cuna
REBCO coated conductor has demonstrated high current capacity that can enable high-field magnets for high energy physics and fusion applications. However, quench protection is still one of the main challenges to be addressed for these applications. In addition, $I_c$ and n value variations along the length of REBCO tapes exist in commercial production. The inter-tape contact resistance plays a key role to develop the self protection capability in cables and magnets by enabling current sharing and suppressing excessive eddy currents. Here we propose an electric-circuit model to describe the inter-tape contact resistance and its impact on the current sharing between REBCO tapes. We report the experiments on a 2-stacked tape REBCO cable with local $I_c$ drop to validate the model. With the developed model, we study the upper limit of the contact resistance which allows current sharing between tapes. We also study the impact of variation in $I_c$ and n values in tapes on the cable performance. Our model is expected to provide useful insight into the current sharing and target values for inter-tape contact resistance in REBCO cables and magnets for various applications.

12 November 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
QJQ. Ji
Q. Ji
PSP. A. Seidl
P. A. Seidl
WWW. L. Waldron
W. L. Waldron
JTJ. H. Takakuwa
J. H. Takakuwa
AFA. Friedman
A. Friedman
TST. Schenkel
T. Schenkel
The neutralized drift compression experiment was designed and commissioned as a pulsed, linear induction accelerator to drive thin targets to warm dense matter (WDM) states with peak temperatures of ∼1 eV using intense, short pulses (∼1 ns) of 1.2 MeV lithium ions. At that kinetic energy, heating a thin target foil near the Bragg peak energy using He+ ions leads to more uniform energy deposition of the target material than Li+ ions. Experiments show that a higher current density of helium ions can be delivered from a plasma source compared to Li+ ions from a hot plate type ion source. He+ beam pulses as high as 200 mA at the peak and 4 μs long were measured from a multi-aperture 7-cm-diameter emission area. Within ±5% variation, the uniform beam area is approximately 6 cm across. The accelerated and compressed pulsed ion beams can be used for materials studies and isochoric heating of target materials for high energy density physics experiments and WDM studies.

1 May 2019 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
JBJianhui Bin
Jianhui Bin
QJQ. Ji
Q. Ji
PSP. A. Seidl
P. A. Seidl
DRD. Raftrey
D. Raftrey
SSS. Steinke
S. Steinke
TSThomas Schenkel
Thomas Schenkel
We report on the calibration of GafChromic HD-v2 radiochromic film in the extremely high dose regime up to 100 kGy together with very high dose rates up to 7 × 1011 Gy/s. The absolute calibration was done with nanosecond ion bunches at the Neutralized Drift Compression Experiment II particle accelerator at Lawrence Berkeley National Laboratory (LBNL) and covers a broad dose dynamic range over three orders of magnitude. We then applied the resulting calibration curve to calibrate a laser driven ion experiment performed on the BELLA petawatt laser facility at LBNL. Here, we reconstructed the spatial and energy resolved distributions of the laser-accelerated proton beams. The resulting proton distribution is in fair agreement with the spectrum that was measured with a Thomson spectrometer in combination with a microchannel plate detector.

26 July 2023 in Physical Review Applied
Verified
Journal Article
Closed access
PDF file
WLWei Liu
Wei Liu
VIVsevolod Ivanov
Vsevolod Ivanov
KJKaushalya Jhuria
Kaushalya Jhuria
QJQing Ji
Qing Ji
APArun Persaud
Arun Persaud
TSThomas Schenkel
Thomas Schenkel
Near-infrared color centers in silicon are emerging candidates for on-chip integrated quantum emitters, optical-access quantum memories, and sensing. We access ensemble G-color-center formation dynamics and radiation-induced atomic disorder in silicon for a series of megaelectronvolt proton-flux conditions. The photoluminescence results reveal that the G centers are formed more efficiently by pulsed-proton irradiation than by continuous-wave proton irradiation. The enhanced transient excitations and dynamic annealing within nanoseconds allows optimization of the ratio of G-center formation to nonradiative defect accumulation. The G centers preserve narrow line widths of about 0.1 nm when they are generated by moderate pulsed-proton fluences, while the line width broadens significantly as the pulsed-proton fluence increases. This implies vacancy or interstitial clustering by overlapping collision cascades. The tracking of G-center properties for a series of irradiation conditions enables sensitive probing of atomic disorder, serving as a complementary analytical method for sensing damage accumulation. Aided by ab initio electronic structure calculations, we provide insight into the atomic disorder induced inhomogeneous broadening by introducing vacancies, silicon interstitials, and oriented strain fields in the vicinity of a G center. A vacancy leads to a tensile strain and can result in either a red shift or a blue shift of the G-center emission, depending on its position relative to the G center. Meanwhile, Si interstitials lead to compressive strain, which results in a monotonic red shift. High-flux and tunable ion pulses enable the exploration of the fundamental dynamics of radiation-induced defects as well as methods for the optimization of G-center formation and qubit synthesis for quantum information processing.

29 January 2004 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
SHS. K. Hahto
S. K. Hahto
SHS. T. Hahto
S. T. Hahto
QJQ. Ji
Q. Ji
KLKa-Ngo Leung
Ka-Ngo Leung
SWS. Wilde
S. Wilde
FLF. M. Levinton
F. M. Levinton
Proton beams are needed in neutral-beam injection for diagnostic development of an internal magnetic field measurement. High proton fraction, low axial energy spread, current density in excess of 30 mA/cm2, and a parallel ion beam with cw operation are the requirements for the ion source/extraction system. A multicusp-type ion source with an external rf antenna was constructed at Lawrence Berkeley National Laboratory. A proton fraction of 85% and proton current density of 32 mA/cm2 were achieved at 1.8 kW of rf power. Plasma parameters were measured with a rf compensated Langmuir probe.

18 June 2015 in Physics Procedia
Verified
Journal Article
Open access
PDF file
QJQing Ji
Qing Ji
BLBernhard Ludewigt
Bernhard Ludewigt
JWJoe Wallig
Joe Wallig
WWWill Waldron
Will Waldron
JTJim Tinsley
Jim Tinsley
Associated particle imaging (API) is a powerful technique for special nuclear material (SNM) detection and characterization of fissile material configurations. A sealed-tube neutron generator has been under development by Lawrence Berkeley National Laboratory to reduce the beam spot size on the neutron production target to 1<!-- --> <!-- -->mm in diameter for a several-fold increase in directional resolution and simultaneously increases the maximum attainable neutron flux. A permanent magnet 2.45<!-- --> <!-- -->GHz microwave-driven ion source has been adopted in this time-tagged neutron source. This type of ion source provides a high plasma density that allows the use of a sub-millimeter aperture for the extraction of a sufficient ion beam current and lets us achieve a much reduced beam spot size on target without employing active focusing. The design of this API generator uses a custom-made radial high voltage insulator to minimize source to neutron production target distance and to provide for a simple ion source cooling arrangement. Preliminary experimental results showed that more than 100 μA of deuterium ions have been extracted, and the beam diameter on the neutron production target is around 1 mm.