Jin-Beom Chung

Jin-Beom Chung

Auto-generated profile, based on publicly available information

Jin-Beom Chung

Department of Radiation Oncology Seoul National University Bundang Hospital Seongnam Republic of Korea

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2019 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
SJSeung Hyuck Jeon
Seung Hyuck Jeon
CSChanghoon Song
Changhoon Song
ECEui Kyu Chie
Eui Kyu Chie
BKBohyoung Kim
Bohyoung Kim
YKYoung Hoon Kim
Young Hoon Kim
JKJae-Sung Kim
Jae-Sung Kim
To develop and compare delta-radiomics signatures from 2- (2D) and 3-dimensional (3D) features that predict treatment outcomes following preoperative chemoradiotherapy (CCRT) and surgery for locally advanced rectal cancer. In total, 101 patients (training cohort, n = 67; validation cohort, n = 34) with locally advanced rectal adenocarcinoma between 2008 and 2015 were included. We extracted 55 features from T2-weighted magnetic resonance imaging (MRI) scans. Delta-radiomics feature was defined as the difference in radiomics feature before and after CCRT. Signatures were developed to predict local recurrence (LR), distant metastasis (DM), and disease-free survival (DFS) from 2D and 3D features. The least absolute shrinkage and selection operator regression was used to select features and build signatures. The delta-radiomics signatures and clinical factors were integrated into Cox regression analysis to determine if the signatures were independent prognostic factors. The radiomics signatures for LR, DM, and DFS were developed and validated using both 2D and 3D features. Outcomes were significantly different in the low- and high-risk patients dichotomized by optimal cutoff in both the training and validation cohorts. In multivariate analysis, the signatures were independent prognostic factors even when considering the clinical parameters. There were no significant differences in C-index from 2D vs. 3D signatures. This is the first study to develop delta-radiomics signatures for rectal cancer. The signatures successfully predicted the outcomes and were independent prognostic factors. External validation is warranted to ensure their performance.

8 November 2015 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
JCJin‐Beom Chung
Jin‐Beom Chung
JKJae-Sung Kim
Jae-Sung Kim
KEKeun‐Yong Eom
Keun‐Yong Eom
IKIn‐Ah Kim
In‐Ah Kim
SKSang‐Won Kang
Sang‐Won Kang
TSTae‐Suk Suh
Tae‐Suk Suh
The purpose of this study is to investigate the feasibility of using a flattening filter‐free (FFF) beam with an endorectal balloon for stereotactic ablative body radiotherapy (SABR) of clinically localized prostate cancer. We assessed plans of SABR with volumetric‐modulated arc therapy (VMAT) that used a flattening filter (FF) beam and an FFF beam and compared the verification results of dosimetric quality assurance for all pretreatment plans. A total of 20 patients with prostate cancer were enrolled in the study. SABR plans using VMAT with two full arcs were optimized in the Eclipse treatment planning system. All plans prescribed 42.7 Gy in 7 fractions of 6.1 Gy each. Four SABR plans were computed for each patient: two with FF beams and two with FFF beams of 6 and 10 MV. For all plans, the cumulative dose‐volume histograms (DVHs) for the target volumes and organs at risk (OARs) were recorded and compared. Pretreatment quality assurance (QA) was performed using the I'mRT MatriXX system and radiochromic EBT3 film to verify treatment delivery, and gamma analysis was used to quantify the agreement between calculations and measurements. In addition, total monitor units (MUs) and delivery time were investigated as technical parameters of delivery. All four plans achieved adequate dose conformity to the target volumes and had comparable dosimetric data. The DVHs of all four plans for each patient were very similar. All plans were highly conformal with and , and the doses were homogeneous (HI = 0.08–0.15). Sparing for the bladder and rectum was slightly better with the 10 MV FF and FFF plans than with the 6 MV FF and FFF plans, but the difference was negligible. However, there was no significant difference in sparing for the other OARs. The mean agreement with the criterion was higher than 97% for verifying all plans. For the criterion, the corresponding agreement values were more than 90%, which showed that the plans were acceptable. The mean MUs and delivery time used were and min for 6 MV FF, and min for 6 MV FFF, and min for 10 MV FF, and and min for 10 MV FFF, respectively. In the current study, the dose distributions of the prostate SABR plans using 6 and 10 MV FFF beams were similar to those using 6 and 10 MV FF beams. However, this study confirmed that SABR treatment using an FFF beam had an advantage with respect to delivery time. In addition, all pretreatment plans were verified as acceptable and their results were comparable. Therefore, the results of this study suggest that the use of an FFF beam for prostate SABR is a feasible and efficient technique, if carefully applied.PACS numbers: 87.55.D, 87.55.dk

22 February 2015 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
TKTaeryool Koo
Taeryool Koo
JCJin-Beom Chung
Jin-Beom Chung
KEKeun-Yong Eom
Keun-Yong Eom
JSJin-Yong Seok
Jin-Yong Seok
IKIn Ah Kim
In Ah Kim
JKJae-Sung Kim
Jae-Sung Kim
To compare the dosimetric effects of Acuros XB (AXB) and Anisotropic Analytical Algorithm (AAA) on volumetric modulated arc therapy (VMAT) planning for postoperative prostate cancer patients irradiated using an endorectal balloon (ERB). We measured central axis doses with film in a phantom containing an air cavity, and compared measurements with calculations of the AAA and AXB. For clinical study, 10 patients who had undergone whole pelvic radiotherapy (WPRT) followed by prostatic bed-only radiotherapy (PBRT) using VMAT were enrolled. An ERB was used for PBRT but not for WPRT. To compare dosimetric parameters, the cumulative dose-volume histograms, mean, maximum, and minimum doses were measured for the planning target volume. Homogeneity of plans were confirmed using V95%, V107% (VX%, percentage volumes receiving at least X% of prescribed doses) and conformity indices (homogeneity index [HI], conformity index [CI], and conformation number [CN]). We compared volumes of the organ-at-risk receiving 10% to 100% (10-tier at 10% interval) of prescribed doses (V10% – V100%). In the phantom study, the AAA showed larger disagreement with the measurements, and overestimated the dose in the air cavity, comparing with the AXB. For WPRT planning, the AAA predicted a lower maximum dose and V107% than the AXB. For PBRT planning, the AAA estimated a higher minimum dose, lower maximum dose, and smaller V107%, and larger V95% than the AXB. Regarding the conformity indices, the AAA was estimated to be more homogenous than the AXB for PBRT planning (HI, 0.088 vs. 0.120, p = 0.005; CI, 1.052 vs. 1.038, p = 0.022; and CN, 0.920 vs. 0.900, p = 0.007) but not for WPRT planning. Among V10% to V100% of the rectum, the PBRT exhibited significant discrepancies in V30%, V40%, V70%, V80%, and V90%; while the WPRT did in V20% and V30%. The phantom study demonstrated that the AXB calculates more accurately in the air cavity than the AAA. In the clinical setting, the AXB exhibited different dosimetric distributions in the VMAT plans for PBRT containing an ERB. The AXB should be considered for prostate cancer patients irradiated with an ERB for better applying of heterogeneous condition.

12 November 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KKKyeong-Hyeon Kim
Kyeong-Hyeon Kim
JCJin-Beom Chung
Jin-Beom Chung
TSTae-Suk Suh
Tae-Suk Suh
SKSang-Won Kang
Sang-Won Kang
SKSeong-Hee Kang
Seong-Hee Kang
JKJae-Sung Kim
Jae-Sung Kim
To investigate feasible treatment planning parameters, we aimed to evaluate the dosimetric and radiobiological impact of the dose calculation algorithm and grid size in the volumetric modulated arc therapy (VMAT) plan for prostate cancer. Twenty patients were selected, and the treatment plans were initially generated with anisotropic analytical algorithm (AAA) and recalculated with Acuros XB (AXB) algorithm. Various dose grids were used for AXB (1, 2, and 3 mm) and AAA (1, 3, and 5 mm) plan. Dosimetric parameters such as homogeneity index (HI) and conformity index (CI), and radiobiological parameters such as tumor control probability (TCP) and normal tissue complication probability (NTCP) were calculated. Significant differences were observed in the planning target volume (PTV) coverage between both algorithms, and the V95%, HI, and CI of AAA were significantly affected by grid (p < 0.01). On 1 mm grid, the mean rectal dose difference between both algorithms was 2.87% of the prescription dose (p < 0.01), which was the highest among the critical organs. The TCP and NTCP of the AAA were higher than those of AXB (p < 0.01). Compared to AXB with 1 mm grid, the 2 mm grid showed comparable dose calculation accuracy with short calculation time. This study found that the PTV and rectum show significant differences according to dose calculation algorithm and grid. Considering the dose calculation performance for heterogeneous area, we recommend AXB with 2 mm grid for improving treatment efficiency of prostate VMAT.

15 January 2017 in Radiology and Oncology
Verified
Journal Article
Open access
PDF file
SKSang Won Kang
Sang Won Kang
JCJin Beom Chung
Jin Beom Chung
JKJae-Sung Kim
Jae-Sung Kim
IKIn Ah Kim
In Ah Kim
KEKeun Yong Eom
Keun Yong Eom
TSTae-Suk Suh
Tae-Suk Suh
The aim of this study was to determine the optimal strategy among various arc arrangements in prostate plans of stereotactic body radiotherapy with volumetric modulated arc therapy (SBRT-VMAT). To investigate how arc arrangements affect dosimetric and biological metrics, SBRT-VMAT plans for eighteen patients were generated with arrangements of single-full arc (1FA), single-partial arc (1PA), double-full arc (2FA), and double-partial arc (2PA). All plans were calculated by the Acuros XB calculation algorithm. Dosimetric and radiobiological metrics for target volumes and organs at risk (OARs) were evaluated from dosevolume histograms. All plans were highly conformal (CI<1.05, CN=0.91) and homogeneous (HI=0.09-0.12) for target volumes. For OARs, there was no difference in the bladder dose, while there was a significant difference in the rectum and both femoral head doses. Plans using 1PA and 2PA showed a strong reduction to the mean rectum dose compared to plans using 1FA and 2FA. Contrastively, the D2% and mean dose in both femoral heads were always lower in plans using 1FA and 2FA. The average tumor control probability and normal tissue complication probability were comparable in plans using all arc arrangements. The use of 1PA had a more effective delivery time and produced equivalent target coverage with better rectal sparing, although all plans using four arc arrangements showed generally similar for dosimetric and biological metrics. However, the D2% and mean dose in femoral heads increased slightly and remained within the tolerance. Therefore, this study suggests that the use of 1PA is an attractive choice for delivering prostate SBRT-VMAT. The aim of this study was to determine the optimal strategy among various arc arrangements in prostate plans of stereotactic body radiotherapy with volumetric modulated arc therapy (SBRT-VMAT). To investigate how arc arrangements affect dosimetric and biological metrics, SBRT-VMAT plans for eighteen patients were generated with arrangements of single-full arc (1FA), single-partial arc (1PA), double-full arc (2FA), and double-partial arc (2PA). All plans were calculated by the Acuros XB calculation algorithm. Dosimetric and radiobiological metrics for target volumes and organs at risk (OARs) were evaluated from dosevolume histograms. All plans were highly conformal (CI<1.05, CN=0.91) and homogeneous (HI=0.09-0.12) for target volumes. For OARs, there was no difference in the bladder dose, while there was a significant difference in the rectum and both femoral head doses. Plans using 1PA and 2PA showed a strong reduction to the mean rectum dose compared to plans using 1FA and 2FA. Contrastively, the D2% and mean dose in both femoral heads were always lower in plans using 1FA and 2FA. The average tumor control probability and normal tissue complication probability were comparable in plans using all arc arrangements. The use of 1PA had a more effective delivery time and produced equivalent target coverage with better rectal sparing, although all plans using four arc arrangements showed generally similar for dosimetric and biological metrics. However, the D2% and mean dose in femoral heads increased slightly and remained within the tolerance. Therefore, this study suggests that the use of 1PA is an attractive choice for delivering prostate SBRT-VMAT.

10 February 2022 in Frontiers in Oncology
Verified
Journal Article
Open access
JSJames J. Sohn
James J. Sohn
MPMitchell Polizzi
Mitchell Polizzi
SKSang-Won Kang
Sang-Won Kang
WKWoo-Hyeong Ko
Woo-Hyeong Ko
YCYong-Hyun Cho
Yong-Hyun Cho
JCJin-Beom Chung
Jin-Beom Chung
Purpose: In high-dose-rate (HDR) brachytherapy, an anisotropic dose distribution may be desirable for achieving a higher therapeutic index, particularly when the anatomy imposes challenges. Several methods to deliver intensity-modulated brachytherapy (IMBT) have been proposed in the literature, however practical implementation is lacking due to issues of increased delivery times and complicated delivery mechanisms. This study presents the novel approach of designing a patient-specific inner shape of an applicator with 3D metal printing for IMBT using an inverse plan optimization model.Methods: The 3D printed patient-specific HDR applicator has an external shape that resembles the conventional brachytherapy applicator. However, at each dwell position of the HDR source, the shielding walls in the interior are divided into six equiangular sections with varying thicknesses. We developed a mathematical model to simultaneously optimize the shielding thicknesses and dwell times according to the patient’s anatomical information to achieve the best possible target coverage. The model, which is a bi-convex optimization problem, is solved using alternating minimization. Finally, the applicator design parameters were input into 3D modeling software and saved in a 3D printable file. The applicator has been tested with both a digital phantom and a simulated clinical cervical cancer patient.Results: The proposed approach showed substantial improvements in the target coverage over the conventional method. For the phantom case, 99.18% of the target was covered by the prescribed dose using the proposed method, compared to only 58.32% coverage achieved by the conventional method. For the clinical case, the proposed method increased the coverage of the target from 56.21% to 99.92%. In each case, both methods satisfied the treatment constraints for neighboring OARs.Conclusion: The study simulates the concept of the IMBT with inverse planning using the 3D printed applicator design. The non-isotropic dose map can be produced with optimized shielding patterns and tailored to individual patient’s anatomy, to plan a more conformal plan.