2 October 2024 in IEEE Sensors Journal
Drinking water that contains microbiological contamination can lead to the spread of dangerous waterborne diseases, posing a significant risk to human health. It is important to detect and identify microbial pathogens (such as bacteria, fungi, viruses, and parasites) in water accurately to prevent these negative situations. In this work, we have proposed an optical-fiber(OF) surface Plasmon resonance (SPR) based sensor for the detection of pathogenic bacteria that are Bacillus Anthracis, Vibrio Cholera, Enterococcus Faecalis, and Escherichia Coli (E. coli) in the drinking water. The finite element method (FEM) is implemented to determine the wavelength sensitivity(WS). The sensor shows excellent performance and can identify the samples externally. The sensor has gold(Au) and gallium nitride(GaN) as the plasmonic sensing layer in nano-grating structures over the surface of the multimode fiber (MMF). It can detect all 4 bacteria from the drinking water with the highest sensitivity achieved is 21276.6 nm/RIU for E.coli . The performance parameters: Detection Accuracy (DA), Signal to Noise Ratio(SNR), Resolution (R), Detection Limit(DL), Quality Factor(QF), and Figure of Merit(FOM) are also evaluated. The results produced by the sensor are superior in comparison to the previously reported biosensors.
19 April 2025 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
13 June 2025 in IEEE Sensors Journal
This paper investigates on biosensor utilizing surface plasmon resonance (SPR) mechanism, which provides improved sensitivity and capability for detecting cancer cells. The biosensor is composed of gold (Au) and molybdenum disulfide (MoS2) as the sensing layers. Finite Element Method (FEM) is utilized in numerical analysis along with wavelength-interrogation technique to detect changes in the refractive index (RI) of human cells both normal and cancerous. Using Bayesian Regularization Artificial Neural Network (BRANN) models, parameters like mean square error (MSE) and R2 were evaluated to determine the efficiency of the biosensor. The best MSE and R2 values were obtained for the number of neurons (N) 45 i.e., 13.727482 and 0.999830, respectively. It can be used on more complicated structures to observe parameter correlation, cover a wide range of parameters, and achieve more accurate findings, especially with a high number of inputs and less time and computing effort. This biosensor exhibited a peak wavelength sensitivity (WS), quality factor (QF) and resolution (R) of 31428.57 nm/RIU, 106373.63 nm/RIU and 3.182×10-6 RIU for MCF-7 cell. Additionally, figure of merit (FOM) and detection accuracy (DA) of 271.43 RIU-1 for MDAMB-231 cell and 13.33 μm-1 for HeLa and Jurkat cells. The suggested technique has a lot of promise to enhance sensing capacity.
19 November 2024 in Plasmonics