Motoharu Hayakawa

Motoharu Hayakawa

Auto-generated profile, based on publicly available information

Motoharu Hayakawa

Department of Neurosurgery Fujita Health University Okazaki Medical Center Okazaki Aichi Japan

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2021 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
SHSaeko Higashiguchi
Saeko Higashiguchi
ASAkiyo Sadato
Akiyo Sadato
INIchiro Nakahara
Ichiro Nakahara
SMShoji Matsumoto
Shoji Matsumoto
MHMotoharu Hayakawa
Motoharu Hayakawa
YHYuichi Hirose
Yuichi Hirose
Background Thromboembolic complications (TECs) are frequent during the endovascular treatment of unruptured aneurysms. To prevent TECs, dual antiplatelet therapy using aspirin and clopidogrel is recommended for the perioperative period. In patients with a poor response, clopidogrel is a risk factor for TECs. To prevent TECs, our study assessed the stratified use of prasugrel. Methods Patients who underwent endovascular therapy for unruptured cerebral aneurysms from April 2017 to August 2019 were enrolled in this clinical study and given premedication with aspirin and clopidogrel for 2 weeks prior to the procedure. P2Y12 reaction units (PRU) were measured using the VerifyNow assay on the day before the procedure (tailored group). In subgroups with PRU <240, the clopidogrel dose was maintained (CPG subgroup). In subgroups with PRU ≥240, clopidogrel was changed to prasugrel (PSG subgroup). We compared the occurrence of TECs with retrospective consecutive cases from January 2015 to March 2017 without PRU assessments (non-tailored group). The frequency of TECs within 30 days was assessed as the primary endpoint. Results The tailored and non-tailored groups comprised 167 and 50 patients, respectively. TECs occurred in 11 (6.6%) and 8 (16%) patients in the tailored and non-tailored groups (P=0.048), respectively. The HR for TECs was significantly reduced in the tailored group (HR 0.3, 95% CI 0.11 to 0.81); P=0.017) compared with the non-tailored group. Conclusion The results suggest that tailored dual antiplatelet therapy medication with PRU significantly reduces the frequency of TECs without increasing hemorrhagic complications.

6 May 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ASAkiyo Sadato
Akiyo Sadato
MHMotoharu Hayakawa
Motoharu Hayakawa
KAKazuhide Adachi
Kazuhide Adachi
INIchiro Nakahara
Ichiro Nakahara
YHYuichi Hirose
Yuichi Hirose
Tight coil packing with density of at least 20%–25% is known to be important for preventing recanalization after embolization of cerebral aneurysms. However, large aneurysms sometimes recanalize regardless of the packing density, suggesting that the absolute residual volume which is determined by aneurysm volume and packing density may be more important risk factor for recanalization. To validate this hypothesis, we analyzed the factors affecting the outcomes of treated aneurysms at our institute. We included 355 small and large aneurysms. The following six factors were obtained from every case: aneurysm volume (mL), neck size (mm), packing density (%), residual volume (mL), rupture status at presentation, and stent assistance (with or without stent). The data were then subjected to multivariate logistic regression analysis to identify significant risk factors for recanalization. Recanalization occurred in 61 aneurysms (17.2%). Significant predictors for recanalization were aneurysm volume (odds ratio, 15.3; P < 0.001) and residual volume (odds ratio, 30.9; P < 0.001), but not packing density (odds ratio, 0.98; P = 0.341). These results showed that for each 0.1-mL increase in aneurysm volume and residual volume, the risk of recanalization increased by 1.3 times and 1.4 times, respectively. The most influential risk factor for recanalization after coil embolization was residual volume, not packing density. The larger the aneurysm volume, the greater the packing density has to be to minimize the residual volume and risk of recanalization. Since tight coil packing has already been aimed, further innovation of coil property or embolization technique may be needed. Otherwise, different treatment modality such as flow diverter or parent artery occlusion may have to be considered.

30 January 2024 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
KYKei Yamashiro
Kei Yamashiro
MHMotoharu Hayakawa
Motoharu Hayakawa
KAKazuhide Adachi
Kazuhide Adachi
MHMitsuhiro Hasegawa
Mitsuhiro Hasegawa
YHYuichi Hirose
Yuichi Hirose
BACKGROUND AND PURPOSE: Tumor embolization through the meningohypophyseal trunk and inferolateral trunk is known to be effective in skull-based tumors; however, microcatheter cannulation into these arteries is difficult, and the number of cases that can be safely embolized is limited. In this study, we present a novel embolization procedure for meningohypophyseal trunk and inferolateral trunk using the distal balloon protection technique and detail its clinical efficacy and complication risks. We developed this procedure to allow safe embolization in patients who cannot be adequately cannulated with microcatheters into these arteries. MATERIALS AND METHODS: Patients who underwent meningohypophyseal trunk or inferolateral trunk embolization using the distal balloon protection technique for skull-based tumors at our institution between 2010 and 2023 were included. In this procedure, the ICA was temporarily occluded with a balloon at the ophthalmic artery bifurcation, the microcatheter was guided to the meningohypophyseal trunk or inferolateral trunk vicinity, and embolic particles were injected into the arteries. The balloon was deflated after the embolic particles, that had refluxed into the ICA, were aspirated. RESULTS: A total of 25 meningohypophyseal trunks and inferolateral trunks were embolized during 21 surgeries. Of these 25 arteries, only nine (36.0%) were successfully cannulated with microcatheters. Nevertheless, effective embolization was achieved in all cases. Permanent complications occurred in only one case (4.8%), in which the central retinal artery was occluded during inferolateral trunk embolization, resulting in a visual field defect. No permanent complications resulting from the embolic cerebral infarction were observed. Of 16 cases that underwent MRI within a week after embolization, however, 11 (68.8%) demonstrated embolic cerebral infarctions. CONCLUSIONS: In patients with skull-based tumors with meningohypophyseal trunk or inferolateal trunk feeders that cannot be catheterized directly, embolization using the distal balloon protection technique for tumor supply can be considered as a salvage technique. ABBREVIATIONS: MHT = meningohypophyseal trunk; ILT = inferolateral trunk; GC = guide catheter; AC = aspiration catheter; FR = flow reverse

1 May 2022 in Journal of Cardiology
Verified
Journal Article
Closed access
YSYoshihiro Sato
Yoshihiro Sato
HKHideki Kawai
Hideki Kawai
MHMeiko Hoshino
Meiko Hoshino
SMShoji Matsumoto
Shoji Matsumoto
MHMotoharu Hayakawa
Motoharu Hayakawa
HIHideo Izawa
Hideo Izawa

26 February 2007 in Cerebrovascular Diseases
Verified
Journal Article
Open access
PDF file
JKJong Sung Kim
Jong Sung Kim
DLDae Kyoon Lee
Dae Kyoon Lee
JBJ.M. de Bray
J.M. de Bray
GMG. Marc
G. Marc
VPV. Pautot
V. Pautot
JBJulien Bogousslavsky
Julien Bogousslavsky

1 January 2019 in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
Verified
Journal Article
Closed access
PDF file
TITakeshi Iwakiri
Takeshi Iwakiri
AIAkihiko Ichikawa
Akihiko Ichikawa
AHAkiyuki Hasegawa
Akiyuki Hasegawa
SHSyusaku Hayakawa
Syusaku Hayakawa
MTMasaru Takeuchi
Masaru Takeuchi
Toshio FukudaToshio Fukuda
Toshio Fukuda
This paper describes a new stent for cerebral catheter operation using electrospinning. In the previous study, we proposed a fractal stent with valve mechanism. In this research, we use electrospinning for fabrication of the fractal stent. We propose a patterning of electrospinning using fabrication of MEMS process. We measure the width of the patterning by electrospinning. In this paper, we show the evaluation of the electrospinning patterning, simulation of thee flow and the fabricated fractal pattern.