Mojgan Alishiri

Mojgan Alishiri

Auto-generated profile, based on publicly available information

Mojgan Alishiri

School of Mechanical Engineering, Sharif University of Technology, Tehran, Iran

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2023 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
SESina Ebrahimi
Sina Ebrahimi
MAMojgan Alishiri
Mojgan Alishiri
ASAmir Shamloo
Amir Shamloo
EPEsmail Pishbin
Esmail Pishbin
PHParnian Hemmati
Parnian Hemmati
HSHossein Shaygani
Hossein Shaygani

6 March 2023 in International Journal of Pharmaceutics
Verified
Journal Article
Closed access
HSHossein Shaygani
Hossein Shaygani
SSSaeed Seifi
Saeed Seifi
ASAmir Shamloo
Amir Shamloo
MGMortaza Golizadeh
Mortaza Golizadeh
SRSeyed Yahya Rahnamaee
Seyed Yahya Rahnamaee
SESina Ebrahimi
Sina Ebrahimi

1 December 2023 in Physics of Fluids
Verified
Journal Article
Open access
PDF file
SESina Ebrahimi
Sina Ebrahimi
ZRZohreh Rostami
Zohreh Rostami
MAMojgan Alishiri
Mojgan Alishiri
ASAmir Shamloo
Amir Shamloo
SHSeyyed Mohammad Ali Hoseinian
Seyyed Mohammad Ali Hoseinian
The privilege of early cancer detection is entangled with many people's lives. Thus, providing an efficient tool to analyze circulating tumor cells (CTCs) would be an immense asset. In this study, a CTC sorting mechanism is introduced by classifying CTCs based on their EpCAM (epithelial cell adhesion molecule) level, a cell surface marker applicable to cancer staging. For this purpose, an integrated microfluidic chip was designed to focus and separate CTCs from blood cells in a divergent serpentine microchannel, and simultaneously, sort CTCs into three categories [low-EpCAM (N1 = 406), medium-EpCAM (N2 = 693), and high-EpCAM (N3 = 1693)] using a magnetic field. The velocity optimizations, using finite element method (FEM), provided a focusing efficiency above ∼95% (for different cell lines) and a CTC separation efficiency above 92%, validated with our experimental results in the passive section. Furthermore, by optimizing the characteristics of the magnet (through several simulations), three optimum designs were achieved, featuring microchannel lengths of 5, 15, and 30 mm in the active section. The innovative approach introduced in this study integrates microfluidic chips, enabling a one-time, high-throughput process with a recovery rate exceeding 99%. This not only reduces costs and runtime but also enhances sorting efficiency for monitoring the stage of cancer progression.