13 June 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
CZChenhao Zhang
Chenhao Zhang
SGSong Guobing
Song Guobing
TWTing Wang
Ting Wang
LYLiming Yang
Liming Yang
The result of single-ended traveling wave fault location method based on Wavelet Transform (WT) will be affected by false Wavelet Transform Modulus Maxima (WTMM) points. In this paper, fault distance/impedance information contained in the wave front of the traveling wave is analyzed first. Then the fitting method based on Generalized Logistic function is proposed to extract the fault information. Based on the fitting results, a Predictor-Corrector fault location method is proposed, which includes the following content: (i) The fitting coefficients of the zero-mode fault current wave front are used to estimate fault distance and fault impedance interval. (ii) The arrival time of the line-mode fault current reflected wave can be calibrated and the distance calculation formula can be selected according to the fault distance estimation interval. (iii) The fault distance will be corrected to be within the fault distance estimation interval if the first reflected wave is undetected. A model of ±400kV DC transmission project is built in PSCAD/EMTDC. The simulation results show that the fitting coefficients can directly correspond to fault distance/impedance. The proposed method can effectively eliminate the influence of the false WTMM points, and give the accurate fault location results as well as fault impedance interval.

17 August 2018 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
GSGuobing Song
Guobing Song
TWTing Wang
Ting Wang
KHKazmi S.T. Hussain
Kazmi S.T. Hussain
The half bridge modular multilevel converter (MMC) coordinated with dc circuit breakers (DCCBs) is one of the most promising solutions for the future multi-terminal HVdc system protection. After the isolation of dc line fault, the electrical quantities of the dc system remain stable and no coupling relationship exists between healthy and faulty poles. Thus, ac adaptive reclose scheme is difficult to be applied in dc transmission systems since the information of the adjacent lines cannot be used to assess whether the line fault is cleared or not. An innovative adaptive reclose scheme applied to the MMC-HVdc system is proposed in this paper by injecting voltage pulses to the faulty line. When the breaker is tripped, the converter and dc faulty line are connected by the main breaker of the hybrid HVdc breaker. On the basis of switching control of solid-state devices in the main breaker, the voltage pulse injection to the dc faulty line is realized. Then, the fault characteristic is identified based on the traveling-wave-based fault location algorithm. A fast restart scheme for the MMC-based bipolar HVdc transmission system is also achieved by this method. The simulation results verify the effectiveness of the proposed method.

20 November 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
CZChenhao Zhang
Chenhao Zhang
SGSong Guobing
Song Guobing
TWTing Wang
Ting Wang
XDXinzhou Dong
Xinzhou Dong
The performance of the traditional derivative-based non-unit traveling wave protection (TWP) in high voltage dc (HVDC) grids shows the problem of low-sensitivity when high-impedance faults occur. In this paper, the characteristics of the fault initial traveling wave are analyzed first, two conclusions can be drawn: i) the distortion degree of the fault initial traveling wave is related to the fault location, ii) the amplitude of the fault initial traveling wave is related to the fault impedance. Then a zero-sequence current fitting method is proposed to obtain parameters respectively reflecting fault impedance and fault distance. When a fault occurs, a fault information extraction method based on the fitting parameters will give the estimation interval of the fault impedance, which provide reference for the adaptive threshold value selection of TWP. In this way, the influence of the fault impedance on TWP can be eliminated. A ±400 kV modular multilevel converter (MMC) HVDC grid is built in PSCAD/EMTDC. The verification of the proposed method considers different installation positions of the current limit inductor. The simulation results show that the proposed method can fast and correctly identify the dc line faults and effectively improves the protection sensitivity in detecting high-impedance faults.

7 June 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
TWTing Wang
Ting Wang
SGSong Guobing
Song Guobing
KHKazmi Sayed Tassawar Hussain
Kazmi Sayed Tassawar Hussain
After the isolation of a single pole-to-ground fault, the adaptive auto-reclosing concept in high voltage dc (HVDC) systems is difficult to be applied due to little coupling between the poles. With fault ride through capability, the hybrid modular multilevel converter (MMC) can be advantageous for future HVDC projects. This research proposes an adaptive auto-reclosing operation for hybrid MMC based bipolar HVDC systems, based on fault identification by characteristic signal injection. The proposed method is based on voltage controllability of healthy pole MMC to inject dc voltage perturbations. Healthy line perturbations result in the induced characteristic signals to the faulty line, which contain information about the fault property. An additional control strategy for hybrid MMC, to inject signals with suitable amplitude and frequency, is also discussed in detail. Then, fault identification is realized by wavelet transform of travelling waves caused by the signal injection. Finally, a dc adaptive single-pole auto-reclosing scheme is proposed to shorten the reclose time and to distinguish between temporary faults and permanent faults. Simulation results verify the effectiveness of the proposed method in PSCAD/EMTDC software.

7 January 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
CZChenhao Zhang
Chenhao Zhang
SGSong Guobing
Song Guobing
TWTing Wang
Ting Wang
LWLei Wu
Lei Wu
LYLiming Yang
Liming Yang
The fast and selective protection using fast dc circuit breaker to break the fault current and isolate faulty lines satisfies the requirement of fault clearance in HVDC grids. However, traditional derivative-based traveling wave protection suffers from low-sensitivity problem when high-impedance faults occur. Based on the analysis of the fault initial traveling wave, it is concluded that the distortion degree of the fault initial traveling wave is related to the location of the fault, and the amplitude of the fault initial traveling wave is related to the fault impedance. Then a Levenberg-Marquart (LM) optimal approximation method is proposed to extract the fault distance information from zero-sequence fault current initial traveling wave. The optimal approximation parameters respectively reflecting the fault distance and fault impedance can be obtained. A non-unit traveling wave protection scheme is proposed based on the parameters. A ±400kV modular multilevel converter (MMC) HVDC grid test system is built in PSCAD/EMTDC to verify the proposed method. The simulation results show that the parameters can directly correspond to the fault distance and fault impedance, and the proposed method can fast and reliably identify dc line faults. Finally, the sensitivity of the proposed method is studied by comparing with three different methods.

29 July 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
SGSong Guobing
Song Guobing
JHJunjie Hou
Junjie Hou
BGBing Guo
Bing Guo
KHKazmi Sayed Tassawar Hussain
Kazmi Sayed Tassawar Hussain
TWTing Wang
Ting Wang
BMBilal Masood
Bilal Masood
To identify the fault area more accurately and improve the reliability and sensitivity of the traditional protection principle on DC lines, an active injection for single-ended protection in the DC grid is proposed. Considering the influence of fault impedance, the effect of frequency-dependent parameters, numerical differential error, and the strength of DC boundary, high controllability of hybrid modular multilevel converter is utilized to inject sinusoidal signals with different frequencies into the line at DC terminal of each converter. Then the single-ended fault identification equation is constructed to preliminarily identify the fault area. According to the amplitude difference of the injection signals in different fault areas, the fault areas of the DC grid can be further distinguished. Simulation results verify the effectiveness of the proposed protection principle, improved reliability and sensitivity of protection, and full length protection of line without DC boundary.