11 March 2022 in IEEE Transactions on Applied Superconductivity
HIAF (High Intensity heavy ion Accelerator Facility) is the new generation heavy ion accelerator under construction in China. The HFRS (FRagment Separator of HIAF) is a fragment separator and also a transfer-line between the Booster Ring and the Spectrometer ring, which has magnetic rigidity up to 25 Tm. HFRS magnet system is composed of 11 superconducting dipoles and 13 sets of triplets. Several multipole magnets (an octupole coil, a quadrupole coil, and a sextupole coil) are nested together to compact the length of the HFRS-line. All of them feature high field gradients (13 T/m, 25 T/m 2 , 105 T/m 3 ) and large bores (320 mm). To reduce the cold mass and ensure the field quality, the whole multipole magnets are all designed with coil-dominated magnets of CCT (Canted Cosine Theta) and DCT (Discrete Cosine Theta). This paper will introduce the general design process of an HFRS multipole module. The development process and test results of the prototype will be presented.
25 February 2022 in IEEE Transactions on Applied Superconductivity
The High Intensity Heavy-ion Accelerator Facility (HIAF) is a new project under construction in China, which will provide beams of stable and unstable heavy ions with high energies, high intensities, and high quality. This paper discusses the superconducting magnet system for this accelerator complex. It will consist of a Nb 3 Sn magnet with the peak field of 12 Tesla for the ECR ion source operated at 45 GHz, 52 solenoids typically 676 mm long with an operating field of 7.5 Tesla for the superconducting Linac called iLinac, 11 superferric dipoles with 320 mm wide good field region, 13 coil-dominated multiplets with an aperture of 320 mm, gradient 13 T/m for the fragment separator HFRS. This paper reports the design and prototype development status of the main components.
8 January 2024 in IEEE Transactions on Applied Superconductivity
Lanzhou Ion Therapy Company Ltd. (Lanith), is developing a new compact heavy ion therapy. The device consists of a superconducting gantry and a 35-meter superconducting synchrotron. A combined function curved Discrete Cosine Theta (DCT) superconducting magnet is the key to miniature heavy ion therapy device. The combined function magnet on the gantry consists of three sets of superconducting magnets with a bending radius of 2 m. The central magnetic field is 3.312 T, and the good field region is not less than 60 mm. In order to reduce the magnet size, DCT coils are used for both the dipole and quadrupole magnets. The quadrupole magnet adopts the closed winding at the end turns, which makes the magnet more compact. This article presents a detailed description of the electromagnetic design and optimization process of the gantry magnet system. In order to achieve the design goal of integral field uniformity, the article applies various new methods, and optimizes the integral field homogeneity for both cases with and without yoke. The first set of magnets is being manufactured and will be completed by the end of the year.
3 May 2023 in IEEE Transactions on Applied Superconductivity
The curved superconducting dipole magnet is the core component of the next generation ion therapy device. The superconducting dipole magnet prototype with a physical bend angle of 90°, a magnetic bend angle of 45°, a bend radius of 800 mm, and a bore of 98 mm diameter is developed in China based on a novel type of canted–cosine–theta (CCT) coil structure. The magnet design and manufacturing, and the quench protection system are reported first, and then the testing process of this curved CCT superconducting magnet, which reached the nominal current of 610 A and generated the magnetic field of 2.018 T, after five quench trainings in liquid helium test is reported, meeting the design indicators. A set of technical routes is explored through the development of the curved CCT magnet, providing support for the future ion therapy.
8 January 2024 in IEEE Transactions on Applied Superconductivity
In order to improve the efficiency of cancer treatment, Lanzhou Ion Therapy Company, Ltd. (LANITH) proposed a miniaturized medical heavy-ion therapy facility. The gantry of the therapy facility is composed of six 45 degree combined function magnets, which are used to generate a dipole field (3.312 T) and a quadrupole field (11.5 T/m) with a good field region of no less than 60mm. The quadrupole coil is distributed on both sides of the dipole coil, and the maximum ramping rate of the magnetic field is 0.6 T/s. The magnet adopts the Discrete Cosine Theta (DCT) geometry, which is wound with six-around-one superconducting cable. Since the gantry is continuously rotating during the treatment process, the design of conduction cooling is required. Temperature rising inside the coil caused by high ramping speed will lead to quench, the design of cooling structure must be taken into consideration to avoid the risk. This article first illustrates beam optics and the electromagnetic design of the magnet, then the theoretical calculation of AC loss (including coil AC loss, Eddy current loss in mechanical structure) and quench protection design. By optimizing the coil cooling structure, reducing the influence of the loss on the magnet, and using quench-back quench protection design, the superconducting magnet will work safely and stably during continuous treatment.
23 January 2024 in IEEE Transactions on Applied Superconductivity
High energy FRagment Separator (HFRS), a full superconducting beam line, consists of 11 dipoles and 13 multiplets with the magnetic rigidity of 25 Tm and the large acceptance of ±165 mm. The multiplet contains three magnets nested with octupole, sextupole, quadrupole or steering dipoles, which are arranged together in a common cryostat. A Coil-dominated multipole magnets based on Discrete-Cosine-Theta (DCT) geometry is presented, which is expected to reduce the cold mass and shorten the length of beam line. A total of 200 G10 mandrels with a diameter greater than 400 mm are required and machined with grooves to hold the 6-around-1 cable securely. In order to minimize the costs and periods of magnets manufacture, injection molding is proposed and capable of mass-producing the formers. The first full-size prototype named L800 (effective length = 800 mm) has been successfully tested. Since the measured integral harmonics of the L800 exceed 10 units (only b 3n component for 2n-pole field), the optimization of magnetic design is carried out to minimize the undesired harmonics. This paper will present the latest of the design and development process of the HFRS multipole magnets.