Klara Valko

Klara Valko

Auto-generated profile, based on publicly available information

Klara Valko

Bio-Mimetic Chromatography Ltd, Business & Technology Centre, Bessemer Drive, Stevenage, Herts, SG1 2DX, United Kingdom

Research Focus & Metrics

Academic Career Length

44Years (1983-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 1986 in Journal of Chromatography A
Verified
Journal Article
Closed access
KGKatalin Ganzler
Katalin Ganzler
ASAndrás Salgó
András Salgó
KVKlára Valkó
Klára Valkó

1 June 1997 in Analytical Chemistry
Verified
Journal Article
Closed access
KVKlára Valkó
Klára Valkó
CBChris Bevan
Chris Bevan
DRDerek Reynolds
Derek Reynolds


1 November 2003 in Journal of Pharmaceutical Sciences
Verified
Journal Article
Closed access
PDF file
KVKlara Valko
Klara Valko
SNShenaz Nunhuck
Shenaz Nunhuck
CBChris Bevan
Chris Bevan
MAMichael H. Abraham
Michael H. Abraham
DRDerek P. Reynolds
Derek P. Reynolds

1 July 2001 in Current Medicinal Chemistry
Verified
Journal Article
Closed access
PDF file
KVKlara Valko
Klara Valko
CDChau My Du
Chau My Du
CBChristopher Bevan
Christopher Bevan
DRDerek P. Reynolds
Derek P. Reynolds
MAMichael H. Abraham
Michael H. Abraham
We propose a rapid method for the measurement of octanol / water partition Coefficients (log Poct) via fast gradient reversed phase retention and the calculation of the hydrogen bond acidity of the compounds. The cycle time of the generic gradient HPLC method is 5 minutes. The general solvation equation obtained for the log Poct values and the fast gradient Chromatographic Hydrophobicity Indices with acetonitrile (CHIACN) and methanol (CHIMeOH) have been established. It has been revealed that the major difference between the log Poct and CHIACN lipophilicity scales is their sensitivity towards the hydrogen bond acidity sigma alpha2 H ) of the compounds. The CHIACN values of the uncharged (neutral) compounds are measured, then the H-bond acidity term sigma alpha2 H ) is calculated from the structures. The log Poct values are expressed using the following equation That was established from the data of 86 diverse compounds Log Poct = 0.054 CHIACN + 1.319sigma alpha2H -1.877 N=86 r=0.970 s=0.29 F=655 A hydrogen bond count (HBC) is not as good as sigma alpha2H as a measure of H-bond acidity but still gives an acceptable equation: Log Poct = 0.047 CHIACN + 0.36 HBC - 1.10 N=86 r=0.943 s=0.39 F=336 In order to improve the correlation between the log Poct and the CHIMeOH values several other terms, such as the H-bond basicity, polarisability and size term should also be considered. Therefore acetonitrile is suggested as the preferred organic modifier. This rapid method can be used as a high throughput lipophilicity screen for combinatorial libraries.

1 August 2000 in Journal of Pharmaceutical Sciences
Verified
Journal Article
Closed access
KVKlara Valko
Klara Valko
CDChau My Du
Chau My Du
CBChristopher D. Bevan
Christopher D. Bevan
DRDerek P. Reynolds
Derek P. Reynolds
MAMichael H. Abraham
Michael H. Abraham