Jeanne Ventre

Jeanne Ventre

Auto-generated profile, based on publicly available information

Jeanne Ventre

Gleamer, Paris, France

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2023 in Radiology
Verified
Journal Article
Closed access
SBSouhail Bennani
Souhail Bennani
NRNor-Eddine Regnard
Nor-Eddine Regnard
JVJeanne Ventre
Jeanne Ventre
LLLouis Lassalle
Louis Lassalle
TNToan Nguyen
Toan Nguyen
GCGuillaume Chassagnon
Guillaume Chassagnon
Background Chest radiography remains the most common radiologic examination, and interpretation of its results can be difficult. Purpose To explore the potential benefit of artificial intelligence (AI) assistance in the detection of thoracic abnormalities on chest radiographs by evaluating the performance of radiologists with different levels of expertise, with and without AI assistance. Materials and Methods Patients who underwent both chest radiography and thoracic CT within 72 hours between January 2010 and December 2020 in a French public hospital were screened retrospectively. Radiographs were randomly included until reaching 500 radiographs, with about 50% of radiographs having abnormal findings. A senior thoracic radiologist annotated the radiographs for five abnormalities (pneumothorax, pleural effusion, consolidation, mediastinal and hilar mass, lung nodule) based on the corresponding CT results (ground truth). A total of 12 readers (four thoracic radiologists, four general radiologists, four radiology residents) read half the radiographs without AI and half the radiographs with AI (ChestView; Gleamer). Changes in sensitivity and specificity were measured using paired t tests. Results The study included 500 patients (mean age, 54 years ± 19 [SD]; 261 female, 239 male), with 522 abnormalities visible on 241 radiographs. On average, for all readers, AI use resulted in an absolute increase in sensitivity of 26% (95% CI: 20, 32), 14% (95% CI: 11, 17), 12% (95% CI: 10, 14), 8.5% (95% CI: 6, 11), and 5.9% (95% CI: 4, 8) for pneumothorax, consolidation, nodule, pleural effusion, and mediastinal and hilar mass, respectively (P < .001). Specificity increased with AI assistance (3.9% [95% CI: 3.2, 4.6], 3.7% [95% CI: 3, 4.4], 2.9% [95% CI: 2.3, 3.5], and 2.1% [95% CI: 1.6, 2.6] for pleural effusion, mediastinal and hilar mass, consolidation, and nodule, respectively), except in the diagnosis of pneumothorax (-0.2%; 95% CI: -0.36, -0.04; P = .01). The mean reading time was 81 seconds without AI versus 56 seconds with AI (31% decrease, P < .001). Conclusion AI-assisted chest radiography interpretation resulted in absolute increases in sensitivity for all radiologists of various levels of expertise and reduced the reading times; specificity increased with AI, except in the diagnosis of pneumothorax. © RSNA, 2023 Supplemental material is available for this article.

3 November 2023 in European Radiology
Verified
Journal Article
Closed access
PDF file
TJThibaut Jacques
Thibaut Jacques
NCNicolas Cardot
Nicolas Cardot
JVJeanne Ventre
Jeanne Ventre
XDXavier Demondion
Xavier Demondion
ACAnne Cotten
Anne Cotten

16 October 2019 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
JVJeanne Ventre
Jeanne Ventre
MPM. Teresa Politi
M. Teresa Politi
JFJuan M. Fernández
Juan M. Fernández
AGArthur R. Ghigo
Arthur R. Ghigo
JGJulien Gaudric
Julien Gaudric
PLPierre‐Yves Lagrée
Pierre‐Yves Lagrée

1 April 2020
Verified
Book Chapter
Closed access
PDF file
JVJeanne Ventre
Jeanne Ventre
FRFrancesca Raimondi
Francesca Raimondi
NBNathalie Boddaert
Nathalie Boddaert
JFJosé Maria Fullana
José Maria Fullana
PLPierre-Yves Lagrée
Pierre-Yves Lagrée

8 July 2021 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
JVJeanne Ventre
Jeanne Ventre
STSalam Abou Taam
Salam Abou Taam
JFJosé Maria Fullana
José Maria Fullana
PLPierre-Yves Lagrée
Pierre-Yves Lagrée
The creation of a communication between an artery and a vein (arteriovenous fistula or AVF), to speed up the blood purification during hemodialysis of patients with renal insufficiency, induces significant rheological and mechanical modifications of the vascular network. In this study, we investigated the impact of the creation of an AVF with a zero-dimensional network model of the vascular system of an upper limb and a one-dimensional model around the anastomosis. We compared the simulated distribution of flow rate in this vascular system with Doppler ultrasound measurements. We studied three configurations: before the creation of the AVF, after the creation of the AVF, and after a focal reduction due to a hyper flow rate. The zero-dimensional model predicted the bounds of the diameter of the superficial vein that respects the flow constraints, assuming a high capillary resistance. We indeed highlighted the importance of knowing the capillary resistance as it is a decisive parameter in the models. We also found that the model reproduced the Doppler measurements of flow rate in every configuration and predicted the distribution of flow in cases where the Doppler was not available. The one-dimensional model allowed studying the impact of a venous constriction on the flow distribution, and the capillary resistance was still a crucial parameter.

24 October 2019 in HAL
Verified
Preprint
Open access
PDF file
JVJeanne Ventre
Jeanne Ventre
FRFrancesca Raimondi
Francesca Raimondi
NBNathalie Boddaert
Nathalie Boddaert
JFJosé Maria Fullana
José Maria Fullana
PLPierre-Yves Lagrée
Pierre-Yves Lagrée
Stenosis, defined by a partial or full obstruction of the arteries, is a frequent anomaly in the cardiovascular system. The pressure drop across a stenosis indicates the severity of the pathology. There is currently no non-invasive method to obtain this pressure drop. In this communication, we use four different blood flow models to compute the pressure in an idealized geometry of stenosis: the steady RNSP model, the Multi-Ring model, the 1D model, and algebraic models. We compare these models on a test case under a steady flow. We then developed a gradient-based parameter estimation method to compare the complex models (1D and Multi-Ring) with algebraic formulas. We used the parameter estimation to evaluate the influence of the geometry, wall elasticity and flow parameter on the empirical coefficients of the algebraic formulas.